Experiments to Quantify the Shielding Efficacy of Materials to be Implemented for Portable Shielding Enclosures that Adequately Mitigate EMI from Lighting Attachment Events

Mitigating electric and magnetic fields induced by lightning strike events is critical for the security and longevity of electrical components. Electromagnetic interference originating from a lightning strike is categorized into the low to medium frequency ranges, commonly referred to as the “magnetic coupling” regime. This low-frequency characteristic brings about the problem of shielding magnetic flux lines. Such shielding can be accomplished with highly conductive materials via the generation of eddy currents or by diverting the flux lines using materials with a large relative permeability. The shielding effectiveness of materials with varying thicknesses and geometry are tested using a pulse forming network having comparable characteristics to a scaled lighting strike. A four-stage Marx generator with a peak current of ~33 kA and a risetime of 1.4 μs is used as the pulse forming network to emulate the scaled electric and magnetic fields. The data collected from these experiments provide information and techniques that can be implemented into the design of a portable, deployable shielding enclosure.

61 RADIATION PROTECTION AND DOSIMETRY↗

Lightning Flash Detection System (LFDS) [Poster]

The Electromagnetics Group wanted another system for detecting lightning flashes near/around the Pantex Plant. The current system in use detects lightning by detecting RF signals at a particular frequency. LFDS detects lightning by detecting flashes of light in the visual and near IR spectrums. This work is primarily focused on detecting cloud-to-ground lightning.

42 ENGINEERING↗

Lightning Current Propagation in Electrical Conduit

Investigation of lightning strikes to conductors ran through long spans of rigid steel conduit was performed. An overdamped-exponential current waveform with controlled peaks and rise rates was used to inject simulated lightning strikes. The impact of the length of wire, length of conduit, grounding location/s, and load type was investigated. Breakdown of 600 V, 12 AWG, THHN insulated wire (3.23 mm OD, 2 mm conductor diameter) was observed for voltages above 45 kV. The presence of resistive loads (between wire and ground) in excess of 20 ohms, or current rise times in excess of 5 kA/μs were found to consistently produce breakdown between wire and conduit. Practical power circuit elements such as outlets and splices were found to breakdown at voltage levels much below the wire insulation failure threshold.

47 OTHER INSTRUMENTATION↗

Effect of Humidity on Charge Decay in Varying Atmospheric Gases

Characterization of surface charge decay for varying materials – PTFE, Acrylic, and metals – of 100 mm diameter, radially symmetric bodies was performed. In a gaseous environment, charged materials will lose their charge depending on gas type, humidity, and other environmental factors. Eventually, the charge will be (1) neutralized by ions or electrons in the surrounding gas (2) distributed by conduction on the material surface or in its volume (3) or neutralized by ions or electrons in the material surface and volume. Metal and polymer samples are charged to a known potential in the tens of kilovolts range, and the decaying voltage is monitored with a non-contact probe until the potential reaches near zero. Humidity has an impact on both groups of materials. As a baseline, in air at 42% relative humidity in an enclosed chamber, a positive charge equivalent to 20 kV potential on a metal sphere of 50 mm radius decays to near zero within 25 minutes. In contrast, the same sphere negatively charged decays slightly faster within 20 minutes. Overall, the humidity has a significant effect on the charge decay time, such that an order of magnitude longer times (hours) are observed at low humidity. Effects of chamber size were also studied, drawing a connection to charge carriers in the air available for decay, with chambers of volume(s): 3.3 105 cm3 and 1.4 106 cm3, respectively.

36 MATERIALS SCIENCE↗

Surface Charge Distribution Mapping Using an Electrostatic Probe

Undesired accumulation of charge on dielectric materials causing electrostatic discharges can be an issue in pulsed power systems and electrical systems in general. As such, an understanding of surface charge distribution, charge accumulation, and decay is required. An in-house no-contact electrostatic probe designed with a 2 mm resolution was fabricated to measure and map surface charge distribution. Designed as a contactless instrument, the probe consisting of a metal rod and low leakage amplifier circuit probes the electric potential near the surface. A scan of the surface then provides the raw data, a potential distribution. The actual probe response - i.e., the surface charge to voltage transfer function, is accounted for in post-processing. This is accomplished via an Inverse Wien Filter - a technique often applied in image processing - to deconvolve the probe response from the measured data. A commercially available electrostatic probe, the Trek 341B meter with a 3455ET probe, capable of measuring +/- 20 kV was compared to the in- house probe that is designed to cover a wider range from +/- 35 kV. A resolution better than the simple probe resolution is achieved through the distribution’s scanning voltage method and deconvolution. Applying repeated scans, surface charge decay was tracked on various polymer materials to determine the material and environment dependence; materials included were PA6, PTFE, and others. As an example of material dependence, samples charged to 20 kV at 65% humidity experience full charge decay in approximately 45 seconds for PA5 (152 mm dia.), while it took about 100 times longer for PTFE (51 mm dia.) to observe the same decay/redistribution of charge.