Search NASA⌕ Search

Engineering topics

Hau-Riege, S.

Publications and source records attributed to Hau-Riege, S..

Monte Carlo transport analysis to assess intensity dependent response of a carbon-doped GaN photoconductor

In this report evaluation of the photoresponse in wurtzite GaN photoconductive switches is presented based on kinetic Monte Carlo simulations. The focus is on electron transport physics and assessment of high frequency operation. The roles of GaN band structure, Pauli exclusion, and treatment of internal fields based on the fast multipole method are all comprehensively included. The implementation was validated through comparisons of velocity-field characteristics for GaN with computational results in the literature. Photocurrent widths of less than ~7 ps for the 1 μm device can be expected, which translates into a 100 GHz upper bound. Photocurrent pulse compression below the laser full width at half maxima at high applied fields are predicted based on the interplay of space-charge effects and the negative differential velocity characteristics of GaN.

36 MATERIALS SCIENCE↗

Subthreshold Erosion of an Organic Polymer Induced by Multiple Shots of an X-Ray Free-Electron Laser

We report solids irradiated by energetic photons can be eroded in two modes, depending on the radiation intensity. High average, low-peak power sources, e.g., synchrotron radiation and high-order harmonics, induce desorption of the material at a low etch rate. In contrast, high-peak-power radiation from extreme ultraviolet and x-ray lasers usually causes a massive removal of the material even by a single shot. In this contribution, an effective material erosion is reported in PMMA exposed to multiple accumulated pulses generated by the free-electron x-ray-laser Linac Coherent Light Source (LCLS, tuned at a photon energy of 830 eV in this study, operated in Menlo Park at Stanford, CA, USA) at a fluence below the single-pulse ablation threshold. The effect is caused by polymer-chain scissions initiated by single photons carrying enough energy to break the C—C bounds. High efficiency of the erosion is supposed to occur due to a correlation of the single-photon effects. The subthreshold damage exhibits a nonlinear dose dependence resulting from a competition between chain scissions and cross-linking processes. The cross-linking is proven by Raman spectroscopy of the irradiated polymer. Two theoretical models of the x-ray free-electron-laser-induced erosion are suggested, which provide an excellent agreement with the experimental results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An x-ray optic calibration facility for high energy density diagnostics

A facility to calibrate x-ray imaging optics was built at Lawrence Livermore National Laboratory to support high energy density (HED) and inertial confinement fusion (ICF) diagnostics such as those at the National Ignition Facility and the Sandia Z-Machine. Calibration of the spectral reflectivity and resolution of these x-ray diagnostics enable absolute determination of the x-ray flux and wavelengths generated in the HED and ICF experiments. Measurement of the optic point spread function is used to determine spatial resolution of the optic. This facility was constructed to measure (1) the x-ray reflectivity to ±5% over a spectral range from 5 to 60 keV; (2) point spread functions with a resolution of 50 μm (currently) and 13 μm (future) in the image plane; and (3) optic distance relative to the x-ray source and detector to within ±100 μm in each dimension. Here, this article describes the capabilities of the calibration facility, concept of operations, and initial data from selected x-ray optics.

47 OTHER INSTRUMENTATION↗

Design and raytrace simulations of a multilayer-coated Wolter x-ray optic for the Z machine at Sandia National Laboratories

Recent breakthroughs in the fabrication of small-radii Wolter optics for astrophysics allow high energy density facilities to consider such optics as novel x-ray diagnostics at photon energies of 15-50 keV. Recently, the Lawrence Livermore National Laboratory, Sandia National Laboratories (SNL), the Smithsonian Astrophysical Observatory, and the NASA Marshall Space Flight Center jointly developed and fabricated the first custom Wolter microscope for implementation in SNL’s Z machine with optimized sensitivity at 17.5 keV. To achieve spatial resolution of order 100-200 microns over a field of view of 5 × 5 × 5 mm 3 with high throughput and narrow energy bandpass, the geometry of the optic and its multilayer required careful design and optimization. While the geometry mainly influences resolution and the field of view of the diagnostic, the mirror coating determines the spectral response and throughput. Here in this paper, we outline the details of the design and fabrication process for the first multilayer-coated Wolter I optic for SNL’s Z machine (Z Wolter), including its W/Si multilayer, and present results of raytrace simulations completed to predict and verify the performance of the optic.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Two-color spatial and temporal temperature measurements using a streaked soft x-ray imager

A dual-channel streaked soft x-ray imager has been designed and used on high energy-density physics experiments at the National Ignition Facility. This streaked imager creates two images of the same x-ray source using two slit apertures and a single shallow angle reflection from a nickel mirror. Thin filters are used to create narrow band pass images at 510 eV and 360 eV. When measuring a Planckian spectrum, the brightness ratio of the two images can be translated into a color-temperature, provided that the spectral sensitivity of the two images is well known. To reduce uncertainty and remove spectral features in the streak camera photocathode from this photon energy range, a thin 100 nm CsI on 50 nm Al streak camera photocathode was implemented. Provided that the spectral shape is well-known, then uncertainties on the spectral sensitivity limits the accuracy of the temperature measurement to approximately 4.5% at 100 eV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The National Ignition Facility modular Kirkpatrick-Baez microscope

Current two-dimensional X-ray imaging at the National Ignition Facility (NIF) uses time resolved pinhole cameras with ∼10-25 μm pinholes. This method has limitations in the smallest resolvable features that can be imaged with reasonable photon statistics for inertial confinement fusion (ICF) applications. ICF sources have a broadband self-emission spectrum that causes the pinhole images obtained, through thin foil filters, to contain a similarly broadband spectrum complicating the interpretation of structure in the source. In order to study phenomena on the scale of ∼5 μm, such as dopant mix in the ICF capsule, a narrow energy band, higher spatial resolution microscope system with improved signal/noise has been developed using X-ray optics. Utilizing grazing incidence mirrors in a Kirkpatrick-Baez microscope (KBM) configuration [P. Kirkpatrick and A. V. Baez, J. Opt. Soc. Am. 38, 766–774 (1948)], an X-ray microscope has been designed and fielded on NIF with four imaging channels. The KBM has ∼12 × magnification, <8 μm resolution, and higher throughput in comparison to similar pinhole systems. The first KBM mirrors are coated with a multilayer mirror to allow a “narrow band” energy response at 10.2 keV with ΔE ∼ 3 keV. By adjusting the mirror coating only, the energy response can be matched to the future experimental requirements. Several mirror packs have been commissioned and are interchangeable in the diagnostic snout.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new streaked soft x-ray imager for the National Ignition Facility

Here, a new streaked soft x-ray imager has been designed for use on high energy-density (HED) physics experiments at the National Ignition Facility based at the Lawrence Livermore National Laboratory. This streaked imager uses a slit aperture, single shallow angle reflection from a nickel mirror, and soft x-ray filtering to, when coupled to one of the NIF’s x-ray streak cameras, record a 4× magnification, one-dimensional image of an x-ray source with a spatial resolution of less than 90 μm. The energy band pass produced depends upon the filter material used; for the first qualification shots, vanadium and silver-on-titanium filters were used to gate on photon energy ranges of approximately 300–510 eV and 200–400 eV, respectively. A two-channel version of the snout is available for x-ray sources up to 1 mm and a single-channel is available for larger sources up to 3 mm. Both the one and two-channel variants have been qualified on quartz wire and HED physics target shots.

42 ENGINEERING↗

NIF S600D Snout Final Design Review (FDR) Report

The S600D is a one or two channel mirror spectrometer which will provide temporal and spatial soft x-ray data in a single NIF shot. It mounts to the existing DIM Imaging Streak Camera (DISC) using the standard NIF kinematic mount design. LLE and LLNL each have responsibilities for the snout. The Laboratory for Laser Energetics (LLE) is subcontracted to design, fabricate, and align the S600D Snout at the OMEGA Laser facility in Rochester, NY before delivery to LLNL. The Snout consists of the Mirror Mount, Kinematic interface to DISC, Slit mount, and filter pack mount. Lawrence Livermore National Laboratory (LLNL) is responsible to fabricate and deliver the Mirror substrates and coatings, Pinhole slits and collimators, Filter material, and Image plates. LLNL is also responsible for the Requirements Definition, Concept of Operations, Debris and Shrapnel analysis, Stakeholder reviews and Integration in the NIF Facility.

42 ENGINEERING↗

Meeting Report: User Workshop on High-Power Lasers at the Linac Coherent Light Source

A two-day international workshop on the physics and integration of high-power lasers with the Linac Coherent Light Source was held in Stanford, USA, on October 1-2, 2013. The workshop was co-organized by UC Berkeley, Lawrence Berkeley, Lawrence Livermore and SLAC National Accelerator Laboratories. More than 150 scientists, including 30 students and postdocs who are working in high-intensity laser-matter interactions, fusion research, and dynamic high-pressure science came together from North America, Europe and Asia. The group discussed the most promising and important new physics experiments that will be enabled by the unique combination of high-power lasers with the world-class LCLS freeelectron laser X-ray beam.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗