Orifice In-flow Efficiency Tests. Volume 1: Test Results. Volume 2: Application to Shuttle Venting During Entry
An investigation was made of the capability for computing internal pressures throughout flight for compartments located within space shuttle vehicles. A test program was conducted at a 6 x 6 foot supersonic wind tunnel to determine orifice efficiencies for the flow of air into a compartment from a flowing external stream. Measurements were made over a Mach number range of 0.7 to 1.9 for varying orifice geometry, vent orientation, vent plate thickness, flat plate boundary layer thickness, and pressure ratio across the vent plate. A computer program developed for outflow venting was modified for use in computing compartment pressures for inflow conditions. Results from both the outflow and inflow computer programs are included. A user's manual and program listing of the inflow venting program are also included.