Search NASA⌕ Search

Engineering topics

Hawreliak, J

Publications and source records attributed to Hawreliak, J.

Temperature dependence of dynamic deformation in FCC metals, aluminum and invar

Laser-driven shock experiments were performed on fcc metals, aluminum and invar, at a range of initial temperatures from approximately 120-800 K to explore the effect of initial temperature on dynamic strength properties at strain rates reaching up to 10 7 s -1 . In aluminum, velocimetry data demonstrated an increase of peak stress of the elastic wave, σ E , with initial temperature. Alternatively, for invar, σ E exhibits little-to-no decrease over the same initial temperature range. Aluminum’s unusual deformation behavior is found to primarily be due to anharmonic vibrational effects. Differences in the magnetic structure of aluminum and invar can account for discrepancies in high rate deformation behavior.

36 MATERIALS SCIENCE↗

Modelling off Hugoniot Loading Using Ramp Compression in Single Crystal Copper

The application of a ramp load to a sample is a method by which the thermodynamic variables of the high pressure state can be controlled. The faster the loading rate, the higher the entropy and higher the temperature. This paper describes moleculer dynamics (MD) simulations with 25 million atoms which investigate ramp loading of single crystal copper. The simulations followed the propagation of a 300ps ramp load to 3Mbar along the [100] direction copper. The simulations were long enough to allow the wave front to steepen into a shock, at which point the simulated copper sample shock melted.

36 MATERIALS SCIENCE↗

Bragg diffraction using a 100 ps 17.5 keV x-ray backlighter and the Bragg diffraction imager

A new diagnostic for measuring Bragg diffraction of petawatt-generated high-energy x rays off a laser-compressed crystal was designed and tested successfully at the Omega EP laser facility on static Mo and Ta (111) oriented single crystal samples using a 17.5 keV Mo K{alpha} backlighter. The Bragg diffraction imager consists of a heavily shielded enclosure and a precisely positioned beam block attached to the enclosure by an aluminum arm. Fuji image plates are used as the x-ray detectors. The diffraction from Mo and Ta (222) crystal planes was clearly detected with a high signal-to-noise. This technique will be applied to shock- and quasi-isentropically loaded single crystals on the Omega EP laser.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bragg diffraction using a 100ps 17.5 keV x-ray backlighter and the Bragg Diffraction Imager

A new diagnostic for measuring Bragg diffraction from a laser-driven crystal using a 100ps 17.5 kV x-ray backlighter source is designed and tested successfully at the Omega EP laser facility on static Mo and Ta single crystal samples using a Mo Ka backlighter. The Bragg Diffraction Imager (BDI) consists of a heavily shielded enclosure and a precisely positioned beam block, attached to the main enclosure by an Aluminum arm. Image plate is used as the x-ray detector. The diffraction lines from Mo and Ta <222> planes are clearly detected with a high signal-to-noise using the 17.5 keV and 19.6 keV characteristic lines generated by a petawatt-driven Mo foil. This technique will be applied to shock and ramp-loaded single crystals on the Omega EP laser. Pulsed x-ray diffraction of shock- and ramp-compressed materials is an exciting new technique that can give insight into the dynamic behavior of materials at ultra-high pressure not achievable by any other means to date. X-ray diffraction can be used to determine not only the phase and compression of the lattice at high pressure, but by probing the lattice compression on a timescale equal to the 3D relaxation time of the material, information about dislocation mechanics, including dislocation multiplication rate and velocity, can also be derived. Both Bragg, or reflection, and Laue, or transmission, diffraction have been developed for shock-loaded low-Z crystalline structures such as Cu, Fe, and Si using nano-second scale low-energy implosion and He-{alpha} x-ray backlighters. However, higher-Z materials require higher x-ray probe energies to penetrate the samples, such as in Laue, or probe deep enough into the target, as in the case of Bragg diffraction. Petawatt laser-generated K{alpha} x-ray backlighters have been developed for use in high-energy radiography of dense targets and other HED applications requiring picosecond-scale burst of hard x-rays. While short pulse lasers are very efficient at producing high-energy x-rays, the characteristic x-rays produced in these thin foil targets are superimposed on a broad bremsstrahlung background and can easily saturate a detector if careful diagnostic shielding and experimental geometry are not implemented. A new diagnostic has been designed to measure Bragg diffraction from laser-driven crystal targets using characteristic x-rays from a short-pulse laser backlighter on the Omega EP laser. The Bragg Diffraction Imager, or BDI, is a TIM-mounted instrument consisting of a heavily shielded enclosure made from 3/8-inch thick Heavymet (W-Fe-Ni alloy) and a precisely positioned beam bock, attached to the main enclosure by an Aluminum arm. The beam block is made of 1-inch thick, Al-coated Heavymet and serves to block the x-rays directly from the petawatt backlight, while allowing the diffraction x-rays from the crystal to pass to the enclosure. A schematic of the BDI is shown in Fig. 1a. Image plates are used as the x-ray detector and are loaded through the top of the diagnostic in an Aluminum, light-tight cartridge. The front of the enclosure can be fitted with various filters to maximize the diffraction signal-to-noise.

42 ENGINEERING↗

A Seeman–Bohlin geometry for high-resolution nanosecond x-ray diffraction measurements from shocked polycrystalline and amorphous materials [Shock compression measurement in a Seeman-Bohlin camera geometry developed for time-resolved x-ray diffraction studies of shocked polycrystalline and amorphous materials]

Here, we report on a focusing x-ray diffraction geometry capable of high-resolution in situ lattice probing from dynamically loaded polycrystalline and amorphous materials. The Seeman–Bohlin-type camera presented here is ideally suited for time-resolved x-ray diffraction measurements performed on high energy multibeam laser platforms. Diffraction from several lattice planes of ablatively shock-loaded 25 μm thick Cu foils was recorded on a focusing circle of diameter D=100 mm with exceptional angular resolution limited only by the spectral broadening of the x-ray source. Excellent agreement was found between the density measured using x-ray diffraction and that inferred from Doppler velocimetry and the known shock Hugoniot of Cu. In addition, x-ray diffraction signal was captured from an amorphous material under static conditions.

36 MATERIALS SCIENCE↗