Search NASA⌕ Search

Engineering topics

Hayes, Christopher

Publications and source records attributed to Hayes, Christopher.

At least 55 records · Page 3

aosco.b1

"Harmonized" aosco.b1 datastream

54 ENVIRONMENTAL SCIENCES↗

aosaeth (01)

The aethalometer provides a real-time readout of the concentration of “black” or “elemental” carbon aerosol particles (BC or E) in an air stream. It measures the rate of change of optical transmission through a spot on a filter where aerosol is continuously collected and calculates the concentration of optically absorbing material in the sample. With a built-in reference check of the optical source and a mass flowmeter to monitor air flow rate, the aethalometer calculates the mean BC content of the sampled air stream and provides on-the-spot readout.

54 ENVIRONMENTAL SCIENCES↗

aosuhsas (01)

The ultra-high-sensitivity aerosol spectrometer (UHSAS) is an optical-scattering, laser-based, aerosol particle spectrometer system for sizing particles in the 60 to 1000 nanometer (nm) range [1–3]. The instrument counts particles in up to 100 user-specified sizing bins. The instrument’s laser illuminates particles, which scatter light. The system captures the peak light signals that are generated. These signals are used for particle sizing, since the amount of light scattered correlates strongly with particle size. The UHSAS is part of the aerosol observing system (AOS).

54 ENVIRONMENTAL SCIENCES↗

aoso3.a1

AOS ozone data

54 ENVIRONMENTAL SCIENCES↗

aospsap3w1s.b1

The aospsap3w1m process reads in data from the aospsap3w.b1 datastream and applies a dilution correction to the aerosol sample flow rate, and a filter loading correction to the absorption coefficients. The filter loading is corrected by multiplying by the Weiss transfer function f_w = 1/1.031 * 1/1.22 * (1/(1.0796 Tr + 0.71)) = 1 / (1.3579 Tr + 0.8931) where Tr is the transmittance for a given wavelength. This form incorporates the initial PSAP transfer function with modifications in Bond 1999 and subsequently in Ogren 2010. The one second (1s) data stream is only created for BNL psap3w instruments where the 1 second samples are available. The one minute (1m) data streams contain the averages of the one second data.

54 ENVIRONMENTAL SCIENCES↗

aoscpcf.b1

aoscpcf.b1 QC'd aoscpcf data

54 ENVIRONMENTAL SCIENCES↗

aosccn100 (01)

The cloud condensation nuclei counter measures the concentration of aerosol particles by drawing an air sample through a column with thermodynamically unstable supersaturated water vapor that can condense onto aerosol particles. Particles that are activated, i.e., grown larger in the process, are counted and sized by an optical particle counter (OPC). In this way the CCN measures activated ambient aerosol particle number concentration as a function of supersaturation. ARM operates both one- and two-column versions of the CCN.

54 ENVIRONMENTAL SCIENCES↗

sp2 (00)

The single-particle soot photometer (SP2) measures the soot (black carbon) mass of individual aerosol particles by laser-induced incandescence down to concentrations as low as ng/m^3. The SP2 is part of the aerosol observing system (AOS).

54 ENVIRONMENTAL SCIENCES↗

aosnephwet (c1)

The nephelometer measures the total scattering and hemispheric backscattering of aerosol. Nephelometers are deployed in pairs, with one measuring the ambient conditions and the other measuring the scattering as a function of slowly increasing or decreasing relative humidity (RH). The combination can then be used to derive the hygroscopic growth factor as a function of RH: f(RH). The nephelometer is part of the aerosol observing system (AOS).

54 ENVIRONMENTAL SCIENCES↗

aospsap3w (c1)

The particle soot absorption photometer collects aerosol particles on a substrate and measures the change in light transmission relative to a reference filter. Bulk particle absorption is derived after correcting for scattering effects. The PSAP is part of the aerosol observing system (AOS).

54 ENVIRONMENTAL SCIENCES↗

aosnephdry (c1)

The nephelometer measures the total scattering and hemispheric backscattering of aerosol. Nephelometers are deployed in pairs, with one measuring the ambient conditions and the other measuring the scattering as a function of slowly increasing or decreasing relative humidity (RH). The combination can then be used to derive the hygroscopic growth factor as a function of RH: f(RH). The nephelometer is part of the aerosol observing system (AOS).

54 ENVIRONMENTAL SCIENCES↗

aosaeth (a1)

The aethalometer provides a real-time readout of the concentration of “black” or “elemental” carbon aerosol particles (BC or E) in an air stream. It measures the rate of change of optical transmission through a spot on a filter where aerosol is continuously collected and calculates the concentration of optically absorbing material in the sample. With a built-in reference check of the optical source and a mass flowmeter to monitor air flow rate, the aethalometer calculates the mean BC content of the sampled air stream and provides on-the-spot readout.

54 ENVIRONMENTAL SCIENCES↗