Search NASA⌕ Search

Engineering topics

He, W

Publications and source records attributed to He, W.

SU-F-J-215: Non-Thermal Pulsed High Intensity Focused Ultrasound Therapy Combined with 5-Aminolevulinic Acid: An in Vivo Pilot Study

Purpose: It has recently been shown that non-thermal pulsed high intensity focused ultrasound (pHIFU) has a cell-killing effect. The purpose of the study is to investigate the sonosensitizing effect of 5-Aminolevulinic Acid (5-ALA) in non-thermal pHIFU cancer therapy. Methods: FaDu human head and neck squamous cell carcinoma cells were injected subcutaneously in the flanks of nude mice. After one to two weeks, the tumors reached the volume of 112 ± 8 mm3 and were assigned randomly into a non-thermal pHIFU group (n=9) and a non-thermal sonodynamic therapy (pHIFU after 5-ALA administration) group (n=7). The pHIFU treatments (parameters: 1 MHz frequency; 25 W acoustic power; 0.1 duty cycle; 60 seconds duration) were delivered using an InSightec ExAblate 2000 system with a GE Signa 1.5T MR scanner. The mice in the non-thermal sonodynamic group received 5-ALA tail-vein injection 4 hours prior to the pHIFU treatment. The tumor growth was monitored using the CT scanner on a Sofie-Biosciences G8 PET/CT system. Results: The tumors in this study grew very aggressively and about 60% of the tumors in this study developed ulcerations at various stages. Tumor growth delay after treatments was observed by comparing the treated (n=9 in pHIFU group; n=7 in sonodynamic group) and untreated tumors (n=17). However, no statistically significant differences were found between the non-thermal pHIFU and non-thermal sonodynamic group. The mean normalized tumor volume of the untreated tumors on Day 7 after their first CT scans was 7.05 ± 0.54, while the normalized volume of the treated tumors on Day 7 after treatment was 5.89 ± 0.79 and 6.27 ± 0.47 for the sonodynamic group and pHIFU group, respectively. Conclusion: In this study, no significant sonosensitizing effects of 5-ALA were obtained on aggressive FaDu tumors despite apparent tumor growth delay in some mice treated with non-thermal sonodynamic therapy.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP4-11: Monitoring Tumor Growth in Subcutaneous Murine Tumor Model in Vivo: A Comparison Between MRI and Small Animal CT

Purpose: The purpose of the study is to compare the volume measurement of subcutaneous tumors in mice with different imaging platforms, namely a GE MRI and a Sofie-Biosciences small animal CT scanner. Methods: A549 human lung carcinoma cells and FaDu human head and neck squamous cell carcinoma cells were implanted subcutaneously into flanks of nude mice. Three FaDu tumors and three A549 tumors were included in this study. The MRI scans were done with a GE Signa 1.5 Tesla MR scanner using a fast T2-weighted sequence (70mm FOV and 1.2mm slice thickness), while the CT scans were done with the CT scanner on a Sofie-Biosciences G8 PET/CT platform dedicated for small animal studies (48mm FOV and 0.2mm slice thickness). Imaging contrast agent was not used in this study. Based on the DICOM images from MRI and CT scans, the tumors were contoured with Philips DICOM Viewer and the tumor volumes were obtained by summing up the contoured area and multiplied by the slice thickness. Results: The volume measurements based on the CT scans agree reasonably with that obtained with MR images for the subcutaneous tumors. The mean difference in the absolute tumor volumes between MRI- and CT-based measurements was found to be −6.2% ± 1.0%, with the difference defined as (VMR – VCT)*100%/VMR. Furthermore, we evaluated the normalized tumor volumes, which were defined for each tumor as V/V{sub 0} where V{sub 0} stands for the volume from the first MR or CT scan. The mean difference in the normalized tumor volumes was found to be 0.10% ± 0.96%. Conclusion: Despite the fact that the difference between normal and abnormal tissues is often less clear on small animal CT images than on MR images, one can still obtain reasonable tumor volume information with the small animal CT scans for subcutaneous murine xenograft models.

60 APPLIED LIFE SCIENCES↗

Characterization of Pt-Au and Ni-Au Clusters on TiO2(110)

The surface composition and properties of Pt-Au and Ni-Au clusters on TiO{sub 2}(110) have been studied by scanning tunneling microscopy (STM), low energy ion scattering (LEIS) and soft X-ray photoelectron spectroscopy (sXPS). STM studies show that bimetallic clusters are formed during sequential deposition of the two metals, regardless of the order of deposition. At the 2 ML of Au/2 ML of Pt or Ni coverages studied here, the second metal contributes to the growth of existing clusters rather than forming new pure metal clusters. LEIS experiments demonstrate that the surfaces of the bimetallic clusters are almost 100% Au when 2 ML of Au is deposited on top of 2 ML of Pt or Ni. However, a much larger fraction of Pt or Ni (50 and 20%, respectively) remains at the surface when 2 ML of Pt or Ni is deposited on 2 ML of Au, most likely due to limited diffusion of atoms within the clusters at room temperature. According to sXPS investigations, the binding energies of the metals in the bimetallic clusters are shifted from those observed for pure metal clusters; the Pt(4f{sub 7/2}) and Ni(3p{sub 3/2}) peaks are shifted to lower binding energies while the position of the Au(4f{sub 7/2}) peak is dominated by surface core level shifts. Pure Pt clusters as well as 0.4 ML of Au on 2 ML of Pt clusters reduce the titania support upon encapsulation after annealing to 800 K, whereas 2 ML of Au on 2 ML of Pt clusters do not reduce titania, presumably because there is no Pt at the surface of the clusters. Pure Ni clusters are also known to become encapsulated upon heating, but the reduction of titania is much less extensive compared to that of pure Pt clusters.

36 MATERIALS SCIENCE↗

Cyclotron maser radiation from inhomogeneous plasmas

Cyclotron maser instabilities are important in space, astrophysical, and laboratory plasmas. While extensive work has been done on these instabilities, most of it deals with homogeneous plasmas with uniform magnetic fields while in practice, of course, the systems are generally inhomogeneous. Here we expand on our previous work [R. A. Cairns, I. Vorgul, and R. Bingham, Phys. Rev. Lett. 101, 215003 (2008)] in which we showed that localized regions of instability can exist in an inhomogeneous plasma and that the way in which waves propagate away from this region is not necessarily obvious from the homogeneous plasma dispersion relation. While we consider only a simple ring distribution in velocity space, because of its tractability, the ideas may point toward understanding the behavior in the presence of more realistic distributions. The main object of the present work is to move away from consideration of the local dispersion relation and show how global growing eigenmodes can be constructed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Generation of 3 GW microwave pulses in X-band from a combination of a relativistic backward-wave oscillator and a helical-waveguide compressor

The phenomenon of passive compression of frequency-modulated (FM) pulses in a dispersive media (DM) was used to increase the peak microwave power up to the multigigawatt level. A helically corrugated waveguide was used as the DM, while a relativistic X-band backward-wave oscillator (RBWO) with a descending-during-the-pulse accelerating voltage served as a source of FM pulses. Compression of pulses down to a halfwidth of 2.2 ns accompanied by a 4.5-fold power increase up to a value of about 3.2 GW has been demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Numerical investigation of auroral cyclotron maser processes

When a mainly rectilinear electron beam is subject to significant magnetic compression, conservation of magnetic moment results in the formation of a horseshoe shaped velocity distribution. It has been shown that such a distribution is unstable to cyclotron emission and may be responsible for the generation of auroral kilometric radiation--an intense rf emission sourced at high altitudes in the terrestrial auroral magnetosphere. Particle-in-cell code simulations have been undertaken to investigate the dynamics of the cyclotron emission process in the absence of cavity boundaries with particular consideration of the spatial growth rate, spectral output and rf conversion efficiency. Computations reveal that a well-defined cyclotron emission process occurs albeit with a low spatial growth rate compared with waveguide bounded simulations. The rf output is near perpendicular to the electron beam with a slight backward-wave character reflected in the spectral output with a well defined peak at 2.68 GHz, just below the relativistic electron cyclotron frequency. The corresponding rf conversion efficiency of 1.1% is comparable to waveguide bounded simulations and consistent with the predictions of kinetic theory that suggest efficient, spectrally well defined emission can be obtained from an electron horseshoe distribution in the absence of radiation boundaries.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Millimeter wave generation from a pseudospark-sourced electron beam

Experimental studies of the production and propagation of an electron beam from a multigap pseudospark discharge are presented. From a three-gap pseudospark, a beam up to 680 A was measured at the anode at an applied dc voltage of 23 kV. This beam can propagate downstream as far as 20 cm in a gaseous environment with no guiding magnetic field, which confirms that the transport of the electron beam was based on the neutralization of the space charge of the electron beam due to the ionization of the gas molecules by the beam itself. The beam is of very small size of 1-3 mm in diameter and is ideal to drive high frequency radiation. Higher energy electron beam pulses were generated using a 14-gap pseudospark discharge powered by a cable pulser capable of producing 120 ns duration and 170 kV voltage pulses. The beam measured had a current of up to 110 A. Interactions between the produced beam and a Ka-band Cherenkov maser and a W-band backward wave oscillator slow wave structure were simulated and designed. Millimeter wave pulses were detected from the Cherenkov maser and backward wave oscillator beam-wave interaction experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laboratory Reproduction of Auroral Magnetospheric Radio Wave Sources

Auroral Kilometric Radiation, AKR, occurs naturally in the polar regions of the Earth's magnetosphere where electrons are accelerated by electric fields into the increasing planetary magnetic dipole. Here conservation of the magnetic moment converts axial to rotational momentum forming a horseshoe distribution in velocity phase space. This distribution is unstable to cyclotron emissions and radiation is emitted in the X-mode. In the laboratory a 75-85kV electron beam of 5-40A was magnetically compressed by a system of solenoids. Results are presented for an electron beam gyrating at cyclotron frequencies of 4.42GHz and 11.7GHz resonating with near cut-off TE01 and TE03 modes respectively. Measurements of the electron transport combined with numerical simulations demonstrated that a horseshoe distribution function was formed in electron velocity space. Analysis of the experimental measurements allowed the inference of the 1D number density as a function of the electron beam pitch angle. The total power emitted experimentally was {approx}19-35 kW with a maximum RF emission efficiency of {approx}2%. These results were compared to those obtained numerically using a 2D PiC code KARAT with a maximum efficiency of 2% predicted for the same mode and frequency, consistent with astrophysical and theoretical results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Axis-encircling electron beam generation using a smooth magnetic cusp for gyrodevices

The generation of an annular-shaped axis-encircling electron beam using a smooth magnetic cusp was studied through numerical simulations and experiments for harmonic operation of a gyrodevice. Two magnetic coils were used to form a magnetic cusp located just downstream from the velvet cathode of an accelerator diode. An electron beam of current 34 A and voltage 130 kV with an adjustable velocity ratio {alpha} up to 1.2 was fully transported to the downstream uniform magnetic field region and used to drive a gyrotron traveling wave amplifier into saturation.

43 PARTICLE ACCELERATORS↗

Free-electron maser based on a cavity with two- and one-dimensional distributed feedback

The study of a coaxial free-electron maser (FEM) based on two-dimensional (2D) and one-dimensional (1D) distributed feedback, driven by a 70 mm diameter, annular electron beam is presented. A new cavity formed with 2D and 1D periodic lattices, positioned at the input and output of the interaction region, respectively, was used. It has been demonstrated that 2D distributed feedback in the input mirror allowed 8 mm radiation emitted from different parts of the electron beam to be synchronized. The FEM operating in the 35.9-38.9 GHz frequency region generated 65 MW, 150 ns duration millimeter wave pulses which contained {approx}10 J of energy in the pulse.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radio frequency resonator structure and diagnostic measurements for a laboratory simulation of Auroral Kilometric Radiation

Auroral Kilometric Radiation is emitted from regions of depleted plasma density in the Earth's polar magnetosphere. The radiation frequency is close to the local electron cyclotron frequency, polarized in the X-mode with an efficiency of {approx}1%, with power up to 1 GW. Kinetic analysis of the instability in the descending auroral flux indicated that the phenomena scaled with the cyclotron frequency. Therefore, an experimental reproduction of the auroral geometry has been created scaled to laboratory dimensions by raising the radiation frequency to the microwave range. The experiment transports a 75-85 keV electron beam through a region of increasing magnetic flux density, with a mirror ratio of up to 30. The experiments measured the mode, spectrum, power, and conversion efficiency of the emitted radiation as a function of the mirror ratio in two resonance regimes, with frequencies of 4.42 and 11.7 GHz. The microwave diagnostics and measurements will be presented in this paper.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental and theoretical studies of a coaxial free-electron maser based on two-dimensional distributed feedback

The first operation of a coaxial free-electron maser (FEM) based on two-dimensional (2D) distributed feedback has been recently observed. Analytical and numerical modeling, as well as measurements, of microwave radiation generated by a FEM with a cavity defined by coaxial structures with a 2D periodic perturbation on the inner surfaces of the outer conductor were carried out. The two-mirror cavity was formed with two 2D periodic structures separated by a central smooth section of coaxial waveguide. The FEM was driven by a large diameter (7 cm), high-current (500 A), annular electron beam with electron energy of 475 keV. Studies of the FEM operation have been conducted. It has been demonstrated that by tuning the amplitude of the undulator or guide magnetic field, modes associated with the different band gaps of the 2D structures were excited. The Ka-band FEM generated 15 MW of radiation with a 6% conversion efficiency, in good agreement with theory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗