Search NASA⌕ Search

Engineering topics

Healy, B.

Publications and source records attributed to Healy, B..

Bayesian model selection for GRB 211211A through multiwavelength analyses

ABSTRACT Although GRB 211211A is one of the closest gamma-ray bursts (GRBs), its classification is challenging because of its partially inconclusive electromagnetic signatures. In this paper, we investigate four astrophysical scenarios as possible progenitors for GRB 211211A: a binary neutron star merger, a black hole–neutron star merger, a core-collapse supernova, and an r-process enriched core collapse of a rapidly rotating massive star (a collapsar). We perform a large set of Bayesian multiwavelength analyses based on different models describing these scenarios and priors to investigate which astrophysical scenarios and processes might be related to GRB 211211A. Our analysis supports previous studies in which the presence of an additional component, likely related to r-process nucleosynthesis, is required to explain the observed light curves of GRB 211211A, as it cannot be explained solely as a GRB afterglow. Fixing the distance to about $350~\rm Mpc$, namely the distance of the possible host galaxy SDSS J140910.47+275320.8, we find a statistical preference for a binary neutron star merger scenario.

(transients:) gamma-ray bursts↗

Results from a multicenter prostate IMRT dosimetry intercomparison for an OCOG-TROG clinical trial

Purpose: A multi-institution dosimetry intercomparison has been undertaken of prostate intensity modulated radiation therapy (IMRT) delivery. The dosimetry intercomparison was incorporated into the quality assurance for site credentialing for the Trans-Tasman Radiation Oncology Group Prostate Fractionated Irradiation Trial 08.01 clinical trial.Methods: An anthropomorphic pelvic phantom with realistic anatomy was used along with multiplanar dosimetry tools for the assessment. Nineteen centers across Australia and New Zealand participated in the study.Results: In comparing planned versus measured dose to the target at the isocenter within the phantom, all centers were able to achieve a total delivered dose within 3% of planned dose. In multiplanar analysis with radiochromic film using the gamma analysis method to compare delivered and planned dose, pass rates for a 5%/3 mm criterion were better than 90% for a coronal slice through the isocenter. Pass rates for an off-axis coronal slice were also better than 90% except for one instance with 84% pass rate.Conclusions: Strengths of the dosimetry assessment procedure included the true anthropomorphic nature of the phantom used, the involvement of an expert from the reference center in carrying out the assessment at every site, and the ability of the assessment to detect and resolve dosimetry discrepancies.

61 RADIATION PROTECTION AND DOSIMETRY↗