Heeger, K. M. [Yale University]

Publications and source records attributed to Heeger, K. M. [Yale University].

Reconstruction of cosmic-ray muon events with CUORE

We report the in-situ 3D reconstruction of through-going muons in the CUORE experiment, a cryogenic calorimeter array searching for neutrinoless double beta (0vββ) decay, leveraging the segmentation of the detector. Due to the slow time response of the detector, time-of-flight estimation is not feasible. Therefore, the track reconstruction is performed using a multi-objective optimization algorithm that relies on geometrical information from the detector as a whole. We measure the integral flux of cosmic-ray muons underground at the Laboratori Nazionali del Gran Sasso, and find our value to be in good agreement with other experiments that have performed a similar measurement. To our knowledge, this work represents the first demonstration of 3D particle tracking and reconstruction of through-going muons with per-event angular determination in a millikelvin cryogenic detector array. The analysis performed for this work will be critical for validating the muon-related background in CUPID, a next-generation 0vββ experiment, and for follow-up studies on detector response and on delayed products induced by cosmic-ray muons.

Adams, D. Q. [University of South Carolina]↗

Sensitivity of the CUPID experiment to $0\nu \beta \beta$ decay of 100 Mo

CUPID is a next-generation bolometric experiment to search for neutrinoless double-beta decay ($0\nu \beta \beta$ ) of 100 Mo using Li 2 MoO 4 scintillating crystals. It will operate 1596 crystals at ~10 mK in the CUORE cryostat at the Laboratori Nazionali del Gran Sasso in Italy. Each crystal will be facing two Ge-based bolometric light detectors for α rejection. We compute the discovery and the exclusion sensitivity of CUPID to $0\nu \beta \beta$ in a Frequentist and a Bayesian framework. This computation is done numerically based on pseudo-experiments. For the CUPID baseline scenario, with a background and an energy resolution of 1.0 x 10 –4 counts/keV/kg/yr and 5 keV FWHM at the Q-value, respectively, this results in a Bayesian exclusion sensitivity (90% c.i.) of $\hat{T}_{1/2} > 1.6 \times 10^{27} \ \textrm{yr}$, corresponding to the effective Majorana neutrino mass of $\hat{m}_{\beta \beta } < \ 9.6$ – 28 meV. The Frequentist discovery sensitivity (3σ ) is $\hat{T}_{1/2}= 1.0 \times 10^{27} \ \textrm{yr}$, corresponding to $\hat{m}_{\beta \beta }= \ 12$ – 36 meV.

Alfonso, K. [Virginia Polytechnic Institute and St↗

Exploring the keV-scale physics potential of CUORE

We present the analysis techniques developed to explore the keV-scale energy region of the Cryogenic Underground Observatory for Rare Events (CUORE) experiment, based on more than 2 metric ton yr of data collected over five years. By prioritizing a stricter selection over a larger exposure, we are able to optimize data selection for thresholds at 10 keV and 3 keV with 691 kg yr and 11 kg yr of data, respectively. We study how the performance varies among the 988-detector array with different detector characteristics and data-taking conditions. We achieve an average baseline resolution of 2.54 ±0.14 keV FWHM and 1.18 ±0.02 keV FWHM for the data selection at 10 keV and 3 keV, respectively. The analysis methods employed reduce the overall background by about an order of magnitude, reaching 2.06±0.05 counts/(keV kg days) and 16±2 counts/(keV kg days) at the thresholds of 10 keV and 3 keV. We evaluate for the first time the near-threshold reconstruction efficiencies of the CUORE experiment, and find these to be 50 ±2% and 26 ±4% at 10 keV and 3 keV, respectively. This analysis provides crucial insights into rare decay studies, new physics searches, and keV-scale background modeling with CUORE. We demonstrate that ton-scale cryogenic calorimeters can operate across a wide energy range, from keV to MeV, establishing their scalability as versatile detectors for rare event and dark matter physics. These findings also inform the optimization of future large mass cryogenic calorimeters to enhance the sensitivity to low-energy phenomena.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Publisher Erratum: A gravity-based mounting approach for large-scale cryogenic calorimeter arrays

In the originally published version of this article, several errors were identified in the author list and acknowledgements section. These have now been corrected as follows: Corrections to the Author List: Barrera has been corrected to Barresi. Copello (affiliation 18) has been corrected to Copello (affiliation 19). F. De Domizio has been corrected to S. Di Domizio. Figueros-Feliciamo has been corrected to Figueroa-Feliciano. Mancarella (affiliations 8, 17) has been corrected to Mancarella (affiliations 8, 18). Manenti (affiliations 18, 19) has been corrected to Manenti (affiliations 19, 20). Mayer (affiliations 3, 20, 31) has been corrected to Mayer (affiliations 3, 21, 31). Pagot has been corrected to Pageot. Puranam (affiliation 20) has been corrected to Puranam (affiliation 21). O. Penek has been corrected to Ö. Penek. L. Pettinacci has been corrected to V. Pettinacci. P. Pirro has been corrected to S. Pirro. Previtale has been corrected to Previtali. Rappoldi (affiliation 18) has been corrected to Rappoldi (affiliation 19). Raselli (affiliation 18) has been corrected to Raselli (affiliation 19). Rizzoli (affiliations 8, 17) has been corrected to Rizzoli (affiliations 8, 18). Rossella (affiliation 18) has been corrected to Rossella (affiliation 19). Correction to the Acknowledgements Section: The following grant numbers were missing and have now been added: This work was supported by NSF-PHY-2412377 and NSF-PHY-1913374. Additionally, on page 11, Section 5, second line, the chemical formula was incorrectly given as Li 2 MO 4 . The correct formula is Li 2 MoO 4 . The original article has been updated to reflect these corrections. The publisher apologizes for the inconvenience.

Alfonso, K. [Virginia Polytechnic Institute and St↗

Publisher Erratum: CUPID, the Cuore upgrade with particle identification

Publisher Erratum: Eur. Phys. J. C (2025) 85:737 https://doi.org/10.1140/epjc/s10052-025-14352-1 The author M. Pavan (affiliations 9 and 10) was missing from the published author list. The online version of the article has been updated to include the author. Additionally, affiliations 4 and 17 have been corrected to reflect the proper institutional order. The publisher apologizes for the inconvenience caused.

Alfonso, K. [Virginia Polytechnic Institute and St↗

Prototype reactor-antineutrino detector based on 6 Li-doped pulse-shape-discriminating plastic scintillator

An aboveground 60-kg reactor-antineutrino detector prototype, comprising a two-dimensional array of 36 6 ⁢Li-doped pulse-shape-sensitive plastic scintillator bars, is described. Each bar is 50 cm long with a square cross section of 5.5 cm. Doped with 6 ⁢Li at 0.1% by mass, the detector is capable of identifying correlated energy depositions for the detection of reactor antineutrinos via the inverse-𝛽-decay (IDB) reaction. Each bar is wrapped with a specular reflector that directs photons toward photomultiplier tubes mounted at both ends of the bar. Here, this paper highlights the construction, key features, and main performance characteristics of the system. The system, which relies on multiple observables such as pulse-shape discrimination, energy, position, and timing, is capable of detecting IBD-like neutron-correlated backgrounds, long-lived decay chains, and cosmogenic isotopes.

Physics↗

A gravity-based mounting approach for large-scale cryogenic calorimeter arrays

Cryogenic calorimeters are among the leading technologies for searching for rare events. The CUPID experiment is exploiting this technology to deploy a tonne-scale detector to search for neutrinoless double-beta decay of 100 Mo. The CUPID collaboration proposed an innovative approach to assembling cryogenic calorimeters in a stacked configuration, held in position solely by gravity. This gravity-based assembly method is unprecedented in the field of cryogenic calorimeters and offers several advantages, including relaxed mechanical tolerances and simplified construction. To assess and optimize its performance, we constructed a medium-scale prototype hosting 28 Li 2 MoO 4 crystals and 30 Ge light detectors, both operated as cryogenic calorimeters at the Laboratori Nazionali del Gran Sasso (Italy). Despite an unexpected excess of noise in the light detectors, the results of this test proved (i) a thermal stability better than ±0.5 mK at 10 mK, (ii) a good energy resolution of Li 2 MoO 4 cryogenic calorimeters, (6.6 ± 2.2) keV FWHM at 2615 keV, and (iii) a Li 2 MoO 4 light yield measured by the closest light detector of 0.36 keV/MeV, sufficient to guarantee the particle identification requested by CUPID.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Half-Life and Precision Shape Measurement of the 2⁢𝜈⁢𝛽⁢𝛽 Decay of 130 Te

Here, we present a new measurement of the 2⁢𝜈⁢𝛽⁢𝛽 half-life of 130 Te (𝑇$^{2⁢𝜈}_{1/2}$) using the first complete model of the CUORE data, based on 1038 kg yr of collected exposure. Thanks to optimized data selection, we achieve a factor of two improvement in precision, obtaining 𝑇$^{2⁢𝜈}_{1/2}$ = (9.32⁢$^{+0.05}_{−0.04}$⁢stat⁢ $^{+0.07}_{−0.07}$⁢syst)×10 20 yr. The signal-to-background ratio is increased by 70% compared to our previous results, enabling the first application of the improved 2⁢𝜈⁢𝛽⁢𝛽 formalism to 130 Te . Within this framework, we determine a credibility interval for the effective axial coupling in the nuclear medium as a function of nuclear matrix elements. We also extract values for the higher-order nuclear matrix element ratios: second-to-first and third-to-first. The second-to-first ratio agrees with nuclear model predictions, while the third-to-first ratio deviates from theoretical expectations. These findings provide essential tests of nuclear models and key inputs for future 0⁢𝜈⁢𝛽⁢𝛽 searches.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

CUPID, the Cuore upgrade with particle identification

CUPID, the CUORE Upgrade with Particle Identification, is a next-generation experiment to search for neutrinoless double beta decay (0 νββ ) and other rare events using enriched Li 2 100 MoO 4 scintillating bolometers. It will be hosted by the CUORE cryostat located at the Laboratori Nazionali del Gran Sasso in Italy. The main physics goal of CUPID is to search for 0 νββ of 100 Mo with a discovery sensitivity covering the full neutrino mass regime in the inverted ordering scenario, as well as the portion of the normal ordering regime with lightest neutrino mass larger than 10 meV. With a conservative background index of 10 −4 cts/(keV·kg·yr), 240 kg isotope mass, 5 keV FWHM energy resolution at 3 MeV and 10 live-years of data taking, CUPID will have a 90% C.L. half-life exclusion sensitivity of 1.8 · 10 27 yr, corresponding to an effective Majorana neutrino mass ( m ββ ) sensitivity of 9–15 meV, and a 3σ discovery sensitivity of 1 · 10 27 yr, corresponding to an m ββ range of 12–21 meV.

Alfonso, K. [Virginia Polytechnic Institute and St↗

Comprehensive Measurement of the Reactor Antineutrino Spectrum and Flux at Daya Bay

This Letter reports the precise measurement of the reactor antineutrino spectrum and flux based on the full dataset of 4.7 ×10 6 inverse-beta-decay candidates collected at Daya Bay near detectors. Expressed in terms of the inverse-beta-decay yield per fission, the antineutrino spectra from all reactor fissile isotopes and the specific 235 U and 239 Pu isotopes are measured with 1.3%, 3%, and 8% uncertainties, respectively, near the 3 MeV spectrum peak in reconstructed energy, reaching the best precision in the world. The total antineutrino flux and isotopic 235 U and 239 Pu fluxes are precisely measured to be 5.84 ± 0.07, 6.16 ± 0.12, and 4.16 ± 0.21 in units of 10 −43 cm 2 /fission. These measurements are compared with the Huber-Mueller model, the reevaluated conversion model based on the Kurchatov Institute measurement, and the latest summation model (SM2023). Furthermore, the Daya Bay flux shows good consistency with the Kurchatov Institute and SM2023 models but disagrees with the Huber-Mueller model. The Daya Bay spectrum, however, disagrees with all model predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reactor antineutrino directionality measurement with the PROSPECT-I detector

The PROSPECT-I detector has several features that enable measurement of the direction of a compact neutrino source. Here, in this paper, a detailed report on the directional measurements made on electron antineutrinos emitted from the High Flux Isotope Reactor is presented. With an estimated true neutrino (reactor to detector) direction of φ = 40.8° ± 0.7° and θ= 98.6° ± 0.4°, the PROSPECT-I detector is able to reconstruct an average neutrino direction of φ = 39.4° ± 2.9° and θ = 97.6° ± 1.6°. This measurement is made with approximately 48 000 Inverse Beta Decay signal events and is the most precise directional reconstruction of reactor antineutrinos to date.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for Fractionally Charged Particles with CUORE

The Cryogenic Underground Observatory for Rare Events (CUORE) is a detector array comprised by 988 5 cm × 5 cm × 5 cm TeO 2 crystals held below 20 mK, primarily searching for neutrinoless double-beta decay in 130 Te. Unprecedented in size among cryogenic calorimetric experiments, CUORE provides a promising setting for the study of exotic throughgoing particles. Using the first tonne year of CUORE’s exposure, we perform a search for hypothesized fractionally charged particles (FCPs), which are well-motivated by various standard model extensions and would have suppressed interactions with matter. Across the searched range of charges 𝑒/24−𝑒/2 no excess of FCP candidate tracks is observed over background, setting leading limits on the underground FCP flux with charges 𝑒/24 −𝑒/5 at 90% confidence level. Using the low background environment and segmented geometry of CUORE, we establish the sensitivity of tonne-scale subkelvin detectors to diverse signatures of new physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗