Search NASA⌕ Search

Engineering topics

Heeter, R.

Publications and source records attributed to Heeter, R..

National Opacity Program: Analysis of Opacity-relevant X-ray Emission Spectra (Milestone Report ID 7121)

We have produced high energy density iron plasmas at temperatures above 1 keV and electron densities exceeding 1023 cm -3 (~ 1 g/cm 3 ) using the Orion laser at the Atomic Weapons Establishment. These plasmas were created by irradiating 50 µm diameter layered targets with frequency doubled (λ = 527 nm), 1 ps laser pulses focused to a 100 µm diameter producing an irradiance of ~ 2 x 10 18 W/cm 2 . The buried layer targets consist of 160 nm iron sulfide (FeS), 60 nm potassium chloride (KCl), and 15 nm carbon. The combined layers are tamped on both sides with 3 µm of parylene-N. The x-ray emission from the plasma was measured using two time-resolved, and four time-integrated Bragg crystal spectrometers, as well as one time-integrated imaging system. One time-resolved x-ray spectrometer measured emission from L-shell transitions in highly charged iron, the other from K-shell transitions in helium-like S 14+ and hydrogen-like S 15+ . The time-integrated spectrometers are intensity-calibrated and measured emission from K-shell transitions in sulfur, potassium, chlorine, and both K-shell and L-shell transitions in iron. The density and temperature of the plasma were determined by modeling the x-ray spectra using different spectral and hydrodynamic modeling packages. A brief overview of the uncertainties associated with the measurements and models are presented. We also give an overview of our 1-D HYDRA-DCA radiation-hydrodynamics model and improvements for future work. Our results aid in assessing experimental uncertainties associated with plasma uniformity and with x-ray emission employed as diagnostics in opacity experiments at temperatures and densities not achievable elsewhere and represent a significant step in creating and diagnosing plasmas near LTE. These results are summarized as part of the completion requirements for milestone 7121

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MagLIFEP and MagLIFSNL

The MagLIF campaign operated by Sandia conducted a total of four shot days in FY17 (one on OMEGA and three on OMEGA-EP) aimed at characterizing the laser heating of underdense plasmas (D2, Ar) at parameters that are relevant to the Magnetized Liner Inertial Fusion (MagLIF) ICF scheme being pursued at Sandia National Laboratories [1] [2]. MagLIF combines fuel preheat, magnetization and pulsed power implosion to significantly relax the implosion velocity and pR required for self-heating. Effective fuel preheat requires coupling several kJ of laser energy into the 10 mm long, underdense (typically ne/nc<0.1) fusion fuel without introducing significant mix. Barriers to achieving this include the presence laser plasma instabilities (LPI) as laser energy is coupled to the initially cold fuel, and the presence of a thin, polyimide laser entrance hole (LEH) foil that the laser must pass through and that can be a significant perturbation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A broadband proton backlighting platform to probe shock propagation in low-density systems

A proton backlighting platform has been developed for the study of strong shock propagation in low-density systems in planar geometry. Electric fields at the converging shock front in inertial confinement fusion implosions have been previously observed, demonstrating the presence of—and the need to understand—strong electric fields not modeled in standard radiation-hydrodynamic simulations. In this planar configuration, long-pulse ultraviolet lasers are used to drive a strong shock into a gas-cell target, while a short-pulse proton backlighter side-on radiographs the shock propagation. Finally, the capabilities of the platform are presented here. Future experiments will vary shock strength and gas fill, to probe shock conditions at different Z and T e .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LBS GatlingGun13A

The High Energy Density Laboratory Physics (HEDLP)-funded Eagle nebula project, in collaboration with the LLNL/ University of Nevada Photoionization / Black Hole Physics effort, has successfully executed the first day of Laboratory Basic Science (LBS) Long Duration Radiator shots, performed at the University of Rochester Laboratory for Laser Energetics Omega EP Laser. This experiment employed a novel technique used a copper multi-hohlraum target with 3 hohlraum filled with a 4mg/cc TPX foam fill to act as a gas surrogate. Each hohlraum was driven with an Omega EP UV beam with either a 6ns pulse with 3.3kJ energy or 10ns pulse with 4.3 kJ. Each hohlraum was heated in succession to generate an 18ns or 30ns, 100 eV x-ray source for future laboratory astrophysics studies. The x-ray source was characterized with the CEA μDMX diagnostic and VISAR using a Quartz shock sample with a CH ablator over a single hohlraum. The Shot day was successful with six hohlraum shots on Omega EP with two 30ns x-ray drive shots. The data indicated that the novel foam-filled multi-hohlraum (‘Gatling Gun’) long –duration source performed as designed with all three hohlraums lighting up without significant inter-hohlraum interference (Figure 1). In addition the x-ray drive source was able to illuminate a Ti photoionization demonstration physics package with a 90 to 100 eV x-ray drive, generating Ti L-shell band radiation as expected. This source will next be applied to study ablation-driven hydrodynamics experiments relevant to the Eagle nebula and use the source and further develop the photoionization studies with a controlled 30ns x-ray source.

42 ENGINEERING↗

Laser-Driven Dynamic Hohlraums

A novel approach for laser-driven inertial confinement fusion is described, that of the laser-driven dynamic hohlraum. Combining direct and x-ray drive, the laser-driven dynamic hohlraum uses a radiatively collapsed shock to confine x-radiation and drive an inner capsule. Ignition is predicted for such a system on the National Ignition Facility. In this LDRD the laser-driven dynamic hohlraum was experimentally investigated on the Omega laser. In addition, the laser-driven dynamic hohlraum was investigated as a possible bright, short duration, continuum x-ray source suitable for opacity experiments. Results from these dynamic hohlraum experiments are presented, showing both agreement with and discrepancies with simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗