Search NASA⌕ Search

Engineering topics

Hembach, R.

Publications and source records attributed to Hembach, R..

Development of a high capacity variable conductance heat pipe.

The high-capacity, pressure-primed, tunnel-artery wick concept was used in a gas-controlled variable conductance heat pipe. A variety of techniques were employed to control the size of gas/vapor bubbles trapped within the artery. Successful operation was attained with a nominal 6-foot long, 1-inch diameter cold reservoir VCHP using ammonia working fluid and nitrogen control gas. The pipe contained a heat exchanger to subcool the liquid in the artery. Maximum transport capacity with a 46-inch effective length was 1200 watts level (more than 50,000 watt-inches) and 800 watts at 0.5-inch adverse tilt.

Kosson, R.↗

Design and test of a self-controlled heat pipe radiator.

A 15,000-W spacecraft waste heat rejection system utilizing heat pipe radiator panels has been investigated. Of the several concepts initially identified, a series system was selected for more in-depth analysis. As a demonstration of system feasibility, a nominal 500-W radiator panel has been designed, built, and bench tested. The panel, which is a module of the 15,000-W system, consists of a variable conductance heat pipe (VCHP) header, and six isothermalizer heat pipes attached to a radiator. The thermal load to the VCHP is supplied by a Freon 21 liquid loop via an integral heat exchanger. This paper describes the results of the system studies and the radiator design. Also presented are test data on the VCHP, heat exchanger and isothermalizer heat pipes.

Swerdling, B.↗

A tunnel wick 100,000 watt-inch heat pipe.

The tunnel wick is a new type of heat pipe artery which can prime in a gravity environment by temperature-induced pressure differences between interior and exterior. The paper discusses the concept and its application in the design of room-temperature high-transport-capacity heat pipes. The analytical model of the system is summarized; and performance data obtained with the aid of a related computer program is included. Test data verifying the concept is presented for several pipes, including an eight-foot-long, 0.9-inch ID heat pipe, using ammonia working fluid, with a transport capacity in excess of 150,000 watt-inches. A brief discussion of potential applications for this type of heat pipe includes a variable conductance device to serve as a radiator header and a high capacity heat transport system.

Kosson, R.↗