Search NASA⌕ Search

Engineering topics

Hen, O.

Publications and source records attributed to Hen, O..

At least 91 records · Page 5

The CLAS12 Backward Angle Neutron Detector (BAND)

The Backward Angle Neutron Detector (BAND) of CLAS12 detects neutrons emitted at backward angles of 155° to 175°, with momenta between 200 and 600 MeV$/c_0$. It is positioned 3-m upstream of the target, consists of 18 rows and 5 layers of 7.2-cm by 7.2-cm scintillator bars, and read out on both ends by PMTs to measure time and energy deposition in the scintillator layers. Between the target and BAND there is a 2-cm thick lead wall followed by a 2-cm veto layer to suppress gammas and reject charged particles. This paper discusses the component-selection tests and the detector assembly. Timing calibrations (including offsets and time-walk) were performed using a novel pulsed-laser calibration system, resulting in time resolutions better than 250 ps (150 ps) for energy depositions above 2 MeV (5 MeV). Cosmic rays and a variety of radioactive sources were used to calibration the energy response of the detector. Scintillator bar attenuation lengths were measured. We report the time resolution results in a neutron momentum reconstruction resolution, $δp/p$ < 1.5% for neutron momentum 200 ≤ $p$ ≤ 600 MeV/c. Final performance of the BAND with CLAS12 is shown, including electron–neutral particle timing spectra and a discussion of the off-time neutral contamination as a function of energy deposition threshold.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A method to determine the electric field of liquid argon time projection chambers using a UV laser system and its application in MicroBooNE

Liquid argon time projection chambers (LArTPCs) are now a standard detector technology for making accelerator neutrino measurements, due to their high material density, precise tracking, and calorimetric capabilities. An electric field (E-field) is required in such detectors to 2020 JINST 15 P07010 drift ionization electrons to the anode where they are collected. The E-field of a TPC is often approximated to be uniform between the anode and the cathode planes. However, significant distortions can appear from effects such as mechanical deformations, electrode failures, or the accumulation of space charge generated by cosmic rays. The latter effect is particularly relevant for detectors placed near the Earth’s surface and with large drift distances and long drift time. To determine the E-field in situ, an ultraviolet (UV) laser system is installed in the MicroBooNE experiment at Fermi National Accelerator Laboratory. The purpose of this system is to provide precise measurements of the E-field, and to make it possible to correct for 3D spatial distortions due to E-field non-uniformities. Here we describe the methodology developed for deriving spatial distortions, the drift velocity and the E-field from UV-laser measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probing Few-Body Nuclear Dynamics via H 3 and He 3 ( e , e ' p ) pn Cross-Section Measurements

Here, we report the first measurement of the (e, e' p) three-body breakup reaction cross sections in helium-3 ( 3 He) and tritium ( 3 H) at large momentum transfer ($\langle{Q^2}\rangle$ ≈ 1.9 (GeV/c) 2 ) and x B > 1 kinematics, where the cross section should be sensitive to quasielastic (QE) scattering from single nucleons. The data cover missing momenta 40 ≤ p miss ≤ 500 MeV/c that, in the QE limit with no rescattering, equals the initial momentum of the probed nucleon. The measured cross sections are compared with state-of-the-art ab-initio calculations. Overall good agreement, within ±20%, is observed between data and calculations for the full p miss range for 3 H and for 100 ≤ p miss ≤ 350 MeV/c for 3 He. Including the effects of rescattering of the outgoing nucleon improves agreement with the data at p miss > 250 MeV/c and suggests contributions from charge-exchange (SCX) rescattering. The isoscalar sum of 3 He plus 3 H, which is largely insensitive to SCX, is described by calculations to within the accuracy of the data over the entire pmiss range. This validates current models of the ground state of the three-nucleon system up to very high initial nucleon momenta of 500 MeV/c.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Calibration of the charge and energy loss per unit length of the MicroBooNE liquid argon time projection chamber using muons and protons

In this paper, we describe a method used to calibrate the position- and time-dependent response of the MicroBooNE liquid argon time projection chamber anode wires to ionization particle energy loss. The method makes use of crossing cosmic-ray muons to partially correct anode wire signals for multiple effects as a function of time and position, including cross-connected TPC wires, space charge effects, electron attachment to impurities, diffusion, and recombination. The overall energy scale is then determined using fully-contained beam-induced muons originating and stopping in the active region of the detector. Using this method, we obtain an absolute energy scale uncertainty of 2% in data. We use stopping protons to further refine the relation between the measured charge and the energy loss for highly-ionizing particles. This data-driven detector calibration improves both the measurement of total deposited energy and particle identification based on energy loss per unit length as a function of residual range. As an example, the proton selection efficiency is increased by 2% after detector calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Valence Structure from Nuclear Deep Inelastic Scattering

Mechanisms of spin-flavor SU(6) symmetry breaking in Quantum Chromodynamics (QCD) are studied via an extraction of the free neutron structure function from a global analysis of deep inelastic scattering (DIS) data on the proton and on nuclei from $A = 2$ (deuterium) to 208 (lead). Modification of the structure function of nucleons bound in atomic nuclei (known as the EMC effect) are consistently accounted for within the framework of a universal modification of nucleons in short-range correlated (SRC) pairs. Our extracted neutron-to-proton structure function ratio $F_2^n/F_2^p$ becomes constant for $x_B \ge 0.6$, equalling $0.47 \pm 0.04$ as $x_B \rightarrow 1$, in agreement with theoretical predictions of perturbative QCD and the Dyson Schwinger equation, and in disagreement with predictions of the Scalar Diquark dominance model. Finally, we also predict $F_2^{^3\mathrm{He}}/F_2^{^3\mathrm{H}}$, recently measured, yet unpublished, by the MARATHON collaboration, the nuclear correction function that is needed to extract $F_2^n/F_2^p$ from $F_2^{^3\mathrm{He}}/F_2^{^3\mathrm{H}}$, and the theoretical uncertainty associated with this extraction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for heavy neutral leptons decaying into muon-pion pairs in the MicroBooNE detector

We present upper limits on the production of heavy neutral leptons (HNLs) decaying to $\mu \pi$ pairs using data collected with the MicroBooNE liquid-argon time projection chamber (TPC) operating at Fermilab. This search is the first of its kind performed in a liquid-argon TPC. We use data collected in 2017 and 2018 corresponding to an exposure of $2.0 \times 10^{20}$ protons on target from the Fermilab Booster Neutrino Beam, which produces mainly muon neutrinos with an average energy of $\approx 800$ MeV. HNLs with higher mass are expected to have a longer time-of-flight to the liquid-argon TPC than Standard Model neutrinos. The data are therefore recorded with a dedicated trigger configured to detect HNL decays that occur after the neutrino spill reaches the detector. We set upper limits at the $90\%$ confidence level on the element $\lvert U_{\mu4}\rvert^2$ of the extended PMNS mixing matrix in the range $\lvert U_{\mu4}\rvert^2<(6.6$-$0.9)\times 10^{-7}$ for Dirac HNLs and $\lvert U_{\mu4}\rvert^2<(4.7$-$0.7)\times 10^{-7}$ for Majorana HNLs, assuming HNL masses between $260$ and $385$ MeV and $\lvert U_{e 4}\rvert^2 = \lvert U_{\tau 4}\rvert^2 = 0$.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probing the core of the strong nuclear interaction

The strong nuclear interaction between nucleons (protons and neutrons) is the effective force that holds the atomic nucleus together. This force stems from fundamental interactions between quarks and gluons (the constituents of nucleons) that are described by the equations of quantum chromodynamics. However, as these equations cannot be solved directly, nuclear interactions are described using simplified models, which are well constrained at typical inter-nucleon distances but not at shorter distances. This limits our ability to describe high-density nuclear matter such as that in the cores of neutron stars. Here we use high-energy electron scattering measurements that isolate nucleon pairs in short-distance, high-momentum configurations, accessing a kinematical regime that has not been previously explored by experiments, corresponding to relative momenta between the pair above 400 mega electron volts per c (c, speed of light in vacuum). As the relative momentum between two nucleons increases and their separation thereby decreases, we observe a transition from a spin-dependent tensor force to a predominantly spin-independent scalar force. These results demonstrate the usefulness of using such measurements to study the nuclear interaction at short distances and also support the use of point-like nucleon models with two- and three-body effective interactions to describe nuclear systems up to densities several times higher than the central density of the nucleus.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reconstruction and Measurement of $\mathcal{O}$(100) MeV Energy Electromagnetic Activity from $\pi^0 \rightarrow \gamma\gamma$ Decays in the MicroBooNE LArTPC

We present results on the reconstruction of electromagnetic (EM) activity from photons produced in charged current νμ interactions with final state π0s. We employ a fully-automated reconstruction chain capable of identifying EM showers of &calO;(100) MeV energy, relying on a combination of traditional reconstruction techniques together with novel machine-learning approaches. These studies demonstrate good energy resolution, and good agreement between data and simulation, relying on the reconstructed invariant π0 mass and other photon distributions for validation. The reconstruction techniques developed are applied to a selection of νμ + Ar → μ + π0 + X candidate events to demonstrate the potential for calorimetric separation of photons from electrons and reconstruction of π0 kinematics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rejecting cosmic background for exclusive charged current quasi elastic neutrino interaction studies with Liquid Argon TPCs; a case study with the MicroBooNE detector

Cosmic ray (CR) interactions can be a challenging source of background for neutrino oscillation and cross-section measurements in surface detectors. We present methods for CR rejection in measurements of charged-current quasielastic-like (CCQE-like) neutrino interactions, with a muon and a proton in the final state, measured using liquid argon time projection chambers (LArTPCs). Using a sample of cosmic data collected with the MicroBooNE detector, mixed with simulated neutrino scattering events, a set of event selection criteria is developed that produces an event sample with minimal contribution from CR background. Depending on the selection criteria used a purity between 50% and 80% can be achieved with a signal selection efficiency between 50% and 25%, with higher purity coming at the expense of lower efficiency. While using a specific dataset from the MicroBooNE detector and selection criteria values optimized for CCQE-like events, the concepts presented here are generic and can be adapted for various studies of exclusive v μ CCQE interactions in LArTPCs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct Observation of Proton-Neutron Short-Range Correlation Dominance in Heavy Nuclei

We measured the triple coincidence$ A(e,e'np)$ and $A(e,e'pp)$ reactions on carbon, aluminum, iron, and lead targets at $Q$ 2 > 1.5 (GeV/c) 2 , $x$ $B$ > 1.1 and missing momentum > 400 MeV/c. This was the first direct measurement of both proton-proton (pp) and neutron-proton (np) short-range correlated (SRC) pair knockout from heavy asymmetric nuclei. For all measured nuclei, the average proton-proton ($pp$) to neutron-proton ($np$) reduced cross-section ratio is about 6%, in agreement with previous indirect measurements. Correcting for Single-Charge Exchange effects decreased the SRC pairs ratio to ~ 3%, which is lower than previous results. Comparisons to theoretical Generalized Contact Formalism (GCF) cross-section calculations show good agreement using both phenomenological and chiral nucleon-nucleon potentials, favoring a lower $pp$ to $np$ pair ratio. The ability of the GCF calculation to describe the experimental data using either phenomenological or chiral potentials suggests possible reduction of scale- and scheme-dependence in cross section ratios. Our results also support the high-resolution description of high-momentum states being predominantly due to nucleons in SRC pairs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design and construction of the MicroBooNE Cosmic Ray Tagger system

The MicroBooNE detector utilizes a liquid argon time projection chamber (LArTPC) with an 85 t active mass to study neutrino interactions along the Booster Neutrino Beam (BNB) at Fermilab. Additionally, with a deployment location near ground level, the detector records many cosmic muon tracks in each beam-related detector trigger that can be misidentified as signals of interest. To reduce these cosmogenic backgrounds, we have designed and constructed a TPC-external Cosmic Ray Tagger (CRT). This sub-system was developed by the Laboratory for High Energy Physics (LHEP), Albert Einstein center for fundamental physics, University of Bern. The system utilizes plastic scintillation modules to provide precise time and position information for TPC-traversing particles. Successful matching of TPC tracks and CRT data will allow us to reduce cosmogenic background and better characterize the light collection system and LArTPC data using cosmic muons. Here, we describe the design and installation of the MicroBooNE CRT system and provide an overview of a series of tests done to verify the proper operation of the system and its components during installation, commissioning, and physics data-taking.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of $\nu_\mu$-Ar multiplicity distributions observed by MicroBooNE to GENIE model predictions

We measure a large set of observables in inclusive charged current muon neutrino scattering on argon with the MicroBooNE liquid argon time projection chamber operating at Fermilab. We evaluate three neutrino interaction models based on the widely used GENIE event generator using these observables. The measurement uses a data set consisting of neutrino interactions with a final state muon candidate fully contained within the MicroBooNE detector. These data were collected in 2016 with the Fermilab Booster Neutrino Beam, which has an average neutrino energy of $800~\hbox {MeV}$ , using an exposure corresponding to $ 5.0\times 10^{19}$ protons-on-target. The analysis employs fully automatic event selection and charged particle track reconstruction and uses a data-driven technique to separate neutrino interactions from cosmic ray background events. We find that GENIE models consistently describe the shapes of a large number of kinematic distributions for fixed observed multiplicity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modified structure of protons and neutrons in correlated pairs

The atomic nucleus is made of protons and neutrons (nucleons), which are themselves composed of quarks and gluons. Understanding how the quark-gluon structure of a nucleon bound in an atomic nucleus is modified by the surrounding nucleons is an outstanding challenge. Although evidence for such modification-known as the EMC effect-was first observed over 35 years ago, there is still no generally accepted explanation for its cause. Recent observations suggest that the EMC effect is related to close-proximity short-range correlated (SRC) nucleon pairs in nuclei. Here we report simultaneous, high-precision measurements of the EMC effect and SRC abundances. We show that EMC data can be explained by a universal modification of the structure of nucleons in neutron-proton SRC pairs and present a data-driven extraction of the corresponding universal modification function. This implies that in heavier nuclei with many more neutrons than protons, each proton is more likely than each neutron to belong to an SRC pair and hence to have distorted quark structure. This universal modification function will be useful for determining the structure of the free neutron and thereby testing quantum chromodynamics symmetry-breaking mechanisms and may help to discriminate between nuclear physics effects and beyond-the-standard-model effects in neutrino experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗