Search NASA⌕ Search

Engineering topics

Henderson, Roger

Publications and source records attributed to Henderson, Roger.

Production of NBL PO plutonium isotopic standards CRM 136A, CRM 137A, and CRM 138A

Lawrence Livermore National Laboratory (LLNL) produced approximately 1 mg units of purified Pu from the parent New Brunswick Laboratory (NBL) certified reference materials (CRM) 137, 136 and 138 isotopic standards for the NBL Program Office (NBL PO) as detailed in the revised project plan. As stated in the plan, three representative units of each material were dispensed at the same time to be characterized at LLNL and provide informational values for the quantity of Pu and progeny nuclides in each unit. NBL PO intends to collect and evaluate isotopic measurement data from multiple laboratories and certify these materials as new isotopic standards C137A, C136A, and C138A, respectively. Soon after production eleven units of each analytical standard were shipped to other analytical laboratories for the certification effort, and 121, 119, and 119 units of C137A, C136A and C138A, respectively were shipped to Mickey Finch at Y12 NBL distribution center in November 2024 (30-gallon drum, TID 003777 PRL 7000005043). Residual purified Pu from the effort is being stored indefinitely in B332 at LLNL. Detailed methods can be found in the production plan, and this report describes and documents aspects of the production effort that are not in or were modified from the original production plan.

and nuclear chemistry↗

Measurement of the Prompt Fission Neutron Spectrum from 800 keV to 10 MeV for 240 Pu($sf$) and for the 240 Pu($n,f$) Reaction Induced by Neutrons of Energy from 1-20 MeV

The presence of 240 Pu in nuclear fuels for reactors has resulted in high uncertainties in the results of reactor and nuclear transmutation calculations because of deficiencies in 240 Pu-related nuclear data. Specifically for the prompt fission neutron spectrum (PFNS) of 240 Pu, there is only one neutron-induced, ($n,f$), measurement at 0.85 MeV incident neutron energy and only one complete spontaneous fission, ($sf$), measurement. This limited availability of data does not sufficiently guide nuclear data evaluations of these quantities. Here we report on a measurement of both the 240 Pu($sf$) and the 240 Pu($n,f$) PFNS, both over the emitted neutron energy range of 0.79–10.0 MeV, and from incident neutron energies of 1.0–20.0 MeV for the ($n,f$) reaction. Measurements were made with a hemispherical array of liquid scintillators at the high-energy Los Alamos Neutron Science Center white neutron source at the Weapons Neutron Research facility as part of the joint LANL-LLNL Chi-Nu experimental campaign to measure actinide fission neutron spectra. These measurements are the first of their kind, and provide clear experimental evidence for second-chance fission, third-chance fission, and pre-equilibrium neutron emission processes in neutron-induced fission of 240 Pu, and are the first ever measurements above 1 MeV incident neutron energy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the 238 U( n,f ) prompt fission neutron spectrum from 10 keV to 10 MeV induced by neutrons with 1.5–20 MeV energy

With the recent emergence of fast nuclear reactors, there has been a corresponding increasing interest in 238 U-related nuclear data. However, while existing literature data span much of the energy ranges of interest for the prompt fission neutron spectrum (PFNS) for neutron-induced fission of 238U, most literature data sets are highly correlated, and thus new, independent measurements of this quantity are needed. In this work, we report the results of a new measurement of the 238 U PFNS at the Los Alamos Neutron Science Center for incident neutron energies from 1.5–20.0 MeV, and outgoing neutron energies of 0.01–10.0 MeV. With some notable exceptions, the present results generally agree with existing literature data, especially with regard to features relating to multichance fission and pre-equilibrium features in the PFNS, thus adding confidence to existing nuclear data evaluations and filling in gaps of knowledge at previously unmeasured incident neutron energies. This result is the third in a series of PFNS measurements by the Chi-Nu collaboration now spanning all three major actinides, 239 Pu, 235 U, and 238 U. Thus, for the first time, we report reliable experimental PFNS ratios and average PFNS energy comparisons for measurements of all three of these isotopes including accurate correlations between the different, but correlated experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

LANL/LLNL 240 Pu( n,f ) Prompt Fission Neutron Spectrum Measurement (Q4 FY2022 Progress Report)

The report details the joint LANL/LLNL measurement of the 240 Pu( n,f ) prompt fission neutron spectrum (PFNS) for incident neutron energies from 1–20 MeV. A summary of the experimental setup, including details of the parallel-plate avalanche counter (PPAC) used for this experiment, beam time awarded and received, and adaptations made for specifically for this experiment are described in Sec. II. Some preliminary results obtained with a portion of the total available statistics from the executed experiment are then described in Sec. III with a discussion of potential benefits and losses if more data were collected. Finally, some primary tasks remaining to convert these data to final results are discussed in Sec. IV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the U 235 ( n , f ) prompt fission neutron spectrum from 10 keV to 10 MeV induced by neutrons of energy from 1 MeV to 20 MeV

The characterization of fission-driven nuclear systems primarily relies on calculations of neutron-induced chain reactions, and these calculations require evaluated nuclear data as input. Calculation accuracy heavily depends on input nuclear data evaluation accuracy, and thus high precision on the experimental input to the nuclear data evaluation is essential for fundamental quantities like the energy spectrum of neutrons emitted from neutron-induced fission (i.e., the prompt fission neutron spectrum, PFNS). Despite decades of measurement efforts, prior to the measurements described in this work there were only three literature data sets for the 235 U(n,f) PFNS at incident neutron energies above 1.0 MeV considered reliable for inclusion in nuclear data evaluations and no reliable data sets above 3.0 MeV incident neutron energy. In this work we report on new measurements of the 235 U(n,f) PFNS spanning a grid of 1.0–20.0 MeV in incident neutron energy and 0.01–10.0 MeV in outgoing (PFNS) neutron energy. These measurements were carried out at the Weapons Neutron Research facility at the Los Alamos Neutron Science Center and used a multifoil parallel-plate avalanche counter target with both a Li-glass and a liquid scintillator detector array in separate experiments to span the quoted outgoing neutron energy ranges. The PFNS results are shown in terms of the energy spectra themselves as well as the average PFNS energy $(\langle{E}\rangle)$ and ratios of $\langle{E}\rangle$ at forward and backward angles. Here, the results are compared with literature data and selected nuclear data evaluations. Generally, the data agree with the ENDF/B-VIII.0 evaluation below 5.0-MeV incident neutron energy and more closely with the JEFF-3.3 evaluation above 5.0 MeV, though no evaluations considered for comparison in this work agree with the data across all of the incident and outgoing neutron energies shown, especially in regions where the third-chance fission process becomes available. Additionally, we show a ratio of the present PFNS results for 235 U(n, f) with a recent and highly correlated experiment to measure the 239 Pu(n, f) PFNS at the same experimental facility and with nearly identical equipment and analysis procedures. Many observations reported in this work are the first of their kind and represent significant advancements for knowledge of the 235 U(n, f) PFNS.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

NBL Pu CRM (Phase 1 Progress Report)

Several 100 μg aliquots of NBL CRM 137 Pu sulfate tetrahydrate were prepared in 20 mL glass vials at some time in the past and are expected to have similar chemical composition and similar concentrations of contaminants as the bulk 250 mg CRM 137 Pu sulfate tetrahydrate units. Thus, these units were characterized and used to test Pu purification chemistry to be employed on the larger unit. For preliminary characterization, the residue of bottle 6 was dissolved in 4 M HNO3/0.01 M HF and transferred quantitatively to a pre-weighed 30 mL Savillex Teflon vial with a total solution mass of approximately 18 g. A gravimetric aliquot was removed from this solution for characterization and the remaining solution was dried down and reconstituted in 8 M HNO 3 to test the anion exchange purification column.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗