Search NASA⌕ Search

Engineering topics

Henning, R.

Publications and source records attributed to Henning, R..

At least 37 records · Page 2

$$\alpha $$-event characterization and rejection in point-contact HPGe detectors

Abstract P-type point contact (PPC) HPGe detectors are a leading technology for rare event searches due to their excellent energy resolution, low thresholds, and multi-site event rejection capabilities. We have characterized a PPC detector’s response to $$\alpha $$ α particles incident on the sensitive passivated and p $$^+$$ + surfaces, a previously poorly-understood source of background. The detector studied is identical to those in the Majorana Demonstrator experiment, a search for neutrinoless double-beta decay ( $$0\nu \beta \beta $$ 0 ν β β ) in $$^{76}$$ 76 Ge. $$\alpha $$ α decays on most of the passivated surface exhibit significant energy loss due to charge trapping, with waveforms exhibiting a delayed charge recovery (DCR) signature caused by the slow collection of a fraction of the trapped charge. The DCR is found to be complementary to existing methods of $$\alpha $$ α identification, reliably identifying $$\alpha $$ α background events on the passivated surface of the detector. We demonstrate effective rejection of all surface $$\alpha $$ α events (to within statistical uncertainty) with a loss of only 0.2% of bulk events by combining the DCR discriminator with previously-used methods. The DCR discriminator has been used to reduce the background rate in the $$0\nu \beta \beta $$ 0 ν β β region of interest window by an order of magnitude in the Majorana Demonstrator and will be used in the upcoming LEGEND-200 experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Signatures of muonic activation in the Majorana Demonstrator

Experiments searching for very rare processes such as neutrinoless double-beta decay require a detailed understanding of all sources of background. Signals from radioactive impurities present in construction and detector materials can be suppressed using a number of well-understood techniques. Background from in situ cosmogenic interactions can be reduced by siting an experiment deep underground. However, the next generation of such experiments have unprecedented sensitivity goals of 10 28 years half-life with background rates of 10 -5 cts/(keV kg yr) in the region of interest. To achieve these goals, the remaining cosmogenic background must be well understood. In the work presented here, Majorana Demonstrator data are used to search for decay signatures of metastable germanium isotopes. Contributions to the region of interest in energy and time are estimated using simulations and compared to Demonstrator data. Correlated time-delayed signals are used to identify decay signatures of isotopes produced in the germanium detectors. A good agreement between expected and measured rate is found and different simulation frameworks are used to estimate the uncertainties of the predictions. The simulation campaign is then extended to characterize the background for the LEGEND experiment, a proposed tonne-scale effort searching for neutrinoless double-beta decay in 76 Ge .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Search for double-β decay of 76 Ge to excited states of 76 Se with the Majorana Demonstrator

The M AJORANA DEMONSTRATOR is a neutrinoless double-β decay search consisting of a low-background modular array of high-purity germanium detectors, ~2/3 of which are enriched to 88% in 76 Ge. The experiment is also searching for double-beta decay of 76 Ge to excited states (e.s.) in 76 Se. 76 Ge can decay into three daughter states of 76 Se, with clear event signatures consisting of a ββ-decay followed by the prompt emission of one or two γ rays. This results with high probability in multi-detector coincidences. In this work, the granularity of the DEMONSTRATOR detector array enables powerful discrimination of this event signature from backgrounds. Using 41.9 kg yr of isotopic exposure, the DEMONSTRATOR has set world leading limits for each e.s. decay of 76 Ge, with 90% CL lower half-life limits in the range of (0.75–4.0) × 10 24 yr. In particular, for the 2ν transition to the first 0 + e.s. of 76 Se, a lower half-life limit of 7.5 × 10 23 yr at 90% CL was achieved.

59 ≤ A ≤ 89↗

ADC Nonlinearity Correction for the Majorana Demonstrator

Imperfections in analog-to-digital conversion cannot be ignored when signal digitization requirements demand both wide dynamic range and high resolution, as is the case for the MAJORANA DEMONSTRATOR 76 Ge neutrinoless double beta decay search. Enabling the experiment's high-resolution spectral analysis and efficient pulse shape discrimination required careful measurement and correction of ADC nonlinearites. Here, a simple measurement protocol was developed that did not require sophisticated equipment or lengthy data taking campaigns. A slope-dependent hysteresis was observed and characterized. A correction applied to digitized waveforms prior to signal processing reduced the differential and integral nonlinearites by an order of magnitude, eliminating these as dominant contributions to the systematic energy uncertainty at the double-beta decay Q value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-time tracking of protein unfolding with time-resolved x-ray solution scattering

The correct folding of proteins is of paramount importance for their function, and protein misfolding is believed to be the primary cause of a wide range of diseases. Protein folding has been investigated with time-averaged methods and time-resolved spectroscopy, but observing the structural dynamics of the unfolding process in real-time is challenging. Here, we demonstrate an approach to directly reveal the structural changes in the unfolding reaction. We use nano- to millisecond time-resolved x-ray solution scattering to probe the unfolding of apomyoglobin. The unfolding reaction was triggered using a temperature jump, which was induced by a nanosecond laser pulse. We demonstrate a new strategy to interpret time-resolved x-ray solution scattering data, which evaluates ensembles of structures obtained from molecular dynamics simulations. We find that apomyoglobin passes three states when unfolding, which we characterize as native, molten globule, and unfolded. The molten globule dominates the population under the conditions investigated herein, whereas native and unfolded structures primarily contribute before the laser jump and 30 μs after it, respectively. The molten globule retains much of the native structure but shows a dynamic pattern of inter-residue contacts. Our study demonstrates a new strategy to directly observe structural changes over the cause of the unfolding reaction, providing time- and spatially resolved atomic details of the folding mechanism of globular proteins.

59 BASIC BIOLOGICAL SCIENCES↗

Results of the MAJORANA DEMONSTRATOR’s Search for Double-Beta Decay of 76 Ge to Excited States of 76 Se

The MAJORANA DEMONSTRATOR is searching for double-beta decay of 76 Ge to excited states (E.S.) in 76Se using a modular array of high purity Germanium detectors. 76 Ge can decay into three E.S.s of 76 Se. The E.S. decays have a clear event signature consisting of a ββ-decay with the prompt emission of one or two γ-rays, resulting in with high probability in a multi-site event. The granularity of the DEMONSTRATOR detector array enables powerful discrimination of this event signature from backgrounds. Using 21.3 kg-y of isotopic exposure, the DEMONSTRATOR has set world leading limits for each E.S. decay, with 90% CL lower half-life limits in the range of (0.56 – 2.1) • 10 24 y. In particular, for the 2v transition to the first 0 + E.S. of 76 Se, a lower half-life limit of 0.68 • 10 24 at 90% CL was achieved.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design improvements to cables and connectors in the Majorana Demonstrator

The Majorana Demonstrator is an experiment constructed to search for neutrinoless double-beta decays in germanium-76 and to demonstrate the feasibility to deploy a ton-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and 76 Ge-enriched germanium p-type point contact detectors totaling 44.1 kg, located at the 4850 level of the Sanford Underground Research Facility in Lead, South Dakota, USA. The Demonstrator uses custom high voltage cables to bias the detectors, as well as custom signal cables and connectors to read out the charge deposited at the point contact of each detector. These low-mass cables and connectors must meet stringent radio purity requirements while being subjected to thermal and mechanical stress. A number of issues have been identified with the currently installed cables and connectors. An improved set of cables and connectors for the Majorana Demonstrator are being developed with the aim of increasing their overall reliability and connectivity. In conclusion, we will discuss some of the issues encountered with the current cables and connectors as well as our improved designs and their initial performance.

42 ENGINEERING↗

Search for neutrinoless double- β decay in Ge 76 with 26 kg yr of exposure from the Majorana Demonstrator

The MAJORANA Collaboration is operating an array of high purity Ge detectors to search for the neutrinoless double-beta decay of $^{76}$Ge. The MAJORANA DEMONSTRATOR consists of 44.1 kg of Ge detectors (29.7 kg enriched to 88% in $^{76}$Ge) split between two modules constructed from ultra-clean materials. Both modules are contained in a low-background shield at the Sanford Underground Research Facility in Lead, South Dakota. We present updated results on the search for neutrinoless double-beta decay in $^{76}$Ge with $26.0\pm0.5$ kg-yr of enriched exposure. With the DEMONSTRATOR's unprecedented energy resolution of 2.53 keV FWHM at $Q_{\beta\beta}$, we observe one event in the region of interest with 0.65 events expected from the estimated background, resulting in a lower limit on the $^{76}$Ge neutrinoless double-beta decay half-life of $2.7\times10^{25}$ yr (90% CL) with a median sensitivity of $4.8\times10^{25}$ yr (90% CL). Depending on the matrix elements used, a 90% CL upper limit on the effective Majorana neutrino mass in the range of 200-433 meV is obtained. The measured background in the low-background configurations is $11.9\pm2.0$ counts/(FWHM t yr).

59 ≤ A ≤ 89↗

Recent results from the Majorana Demonstrator

The MAJORANA DEMONSTRATOR is an experiment constructed to search for Neutrinoless double-beta decay in 76Ge and to demonstrate the feasibility to deploy a large-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and 76Ge-enriched germanium detectors totalling 44.1 kg, operating on the 4850’ level of the Sanford Underground Research Facility in Lead, South Dakota, USA. Data acquisition in the commissioning phase began in June 2015, followed by data acquisition with the full detector array in August 2016. The ultralow background and record energy resolution achieved by the MAJORANA DEMONSTRATOR enable a sensitive neutrinoless double-beta decay search, as well as additional searches for physics beyond the Standard Model. I will discuss the design elements that enable these searches, along with our latest results, focusing on the neutrinoless double-beta decay search. I will also discuss the current status and the future plans of the MAJORANA DEMONSTRATOR, as well as the plans for a future tonne-scale 76Ge experiment.

Myslik, Jordan W.↗

Multisite event discrimination for the majorana demonstrator

The MAJORANA DEMONSTRATOR is searching for neutrinoless double-beta decay($0\nu\beta\beta$) in 76 Ge using arrays of point-contact germanium detectors operating at the Sanford Underground Research Facility. Background results in the $0\nu\beta\beta$ region of interest from data taken during construction, commissioning, and the start of full operations have been recently published. A pulse shape analysis cut applied to achieve this result, named AvsE , is described in this paper. This cut is developed to remove events whose waveforms are typical of multi-site energy deposits while retaining (90 ± 3.5)% of single-site events. This pulse shape discrimination is based on the relationship between the maximum current and energy, and tuned using 228 Th calibration source data. In conclusion, the efficiency uncertainty accounts for variation across detectors, energy, and time, as well as for the position distribution difference between calibration and $0\nu\beta\beta$ events, established using simulations.

59 ≤ A ≤ 89↗

The Majorana Demonstrator Status and Preliminary Results

The MAJORANA Collaboration is using an array of high-purity Ge detectors to search for neutrinoless double-beta decay in 76 Ge. Searches for neutrinoless double-beta decay are understood to be the only viable experimental method for testing the Majorana nature of the neutrino. Observation of this decay would imply violation of lepton number, that neutrinos are Majorana in nature, and provide information on the neutrino mass. The MAJORANA DEMONSTRATOR comprises 44.1 kg of p-type point-contact Ge detectors (29.7 kg enriched in 76 Ge) surrounded by a low-background shield system. The experiment achieved a high efficiency of converting raw Ge material to detectors and an unprecedented detector energy resolution of 2.5 keV FWHM at Q ββ . The MAJORANA collaboration began taking physics data in 2016. Here, this paper summarizes key construction aspects of the Demonstrator and shows preliminary results from initial data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Recent Results from the Majorana Demonstrator

The MAJORANA Collaboration has completed construction and is now operating an array of high purity Ge detectors searching for neutrinoless double-beta decay ($0\nu\beta\beta$) in $^{76}$Ge. The array, known as the MAJORANA DEMONSTRATOR, is comprised of 44 kg of Ge detectors (30 kg enriched to 88% in $^{76}$Ge) installed in an ultra-low background compact shield at the Sanford Underground Research Facility in Lead, South Dakota. The primary goal of the DEMONSTRATOR is to establish a low-background design that can be scaled to a next-generation tonne-scale experiment. This work reports initial background levels in the $0\nu\beta\beta$ region of interest. Also presented are recent physics results leveraging P-type point-contact detectors with sub-keV energy thresholds to search for physics beyond the Standard Model; first results from searches for bosonic dark matter, solar axions, Pauli exclusion principle violation, and electron decay have been published. Finally, this work discusses the proposed tonne-scale $^{76}$Ge $0\nu\beta\beta$ LEGEND experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for Neutrinoless Double-ß Decay in 76Ge with the Majorana Demonstrator

The Majorana Collaboration is operating an array of high purity Ge detectors to search for neutrinoless double-beta decay in 76Ge. The Majorana Demonstrator is comprised of 44.8 kg (29.7 kg enriched in 76Ge) of Ge detectors in total, split between two modules contained in a low background shield at the Sanford Underground Research Facility in Lead, South Dakota. Here we present results from data taken during construction, commissioning, and the start of full operations. Given the unprecedented energy resolution at Q of 2.5 keV FWHM and the very low background with no observed candidate events in 10 kg yr of enriched Ge exposure, we find a lower limit on the half-life of 1:9 x 1025 yr (90% CL). This result constrains the effective Majorana neutrino mass to below 250 to 550 meV, depending on the matrix elements used. In our experimental configuration with the lowest background, the background is 4:0 +3:1(superscript) -2:5 (subscript) counts/(FWHM t yr) at 68% CL.

Aalseth, Craig E.↗

Contamination control and assay results for the Majorana Demonstrator ultra clean components

The Majorana Demonstrator is a neutrinoless double beta decay experiment utilizing enriched Ge-76 detectors in 2 separate modules inside of a common solid shield at the Sanford Underground Research Facility. The Demonstrator has utilized world leading assay sensitivities to develop clean materials and processes for producing ultra-pure copper and plastic components. This experiment is now operating, and initial data provide new insights into the success of cleaning and processing. Post production copper assays after the completion of Module 1 showed an increase in U and Th contamination in finished parts compared to starting bulk material. A revised cleaning method and additional round of surface contamination studies prior to Module 2 construction have provided evidence that more rigorous process control can reduce surface contamination. In conclusion, this article describes the assay results and discuss further studies to take advantage of assay capabilities for the purpose of maintaining ultra clean fabrication and process design.

36 MATERIALS SCIENCE↗

Low background materials and fabrication techniques for cables and connectors in the Majorana Demonstrator

Here, the Majorana Collaboration is searching for the neutrinoless double-beta decay of the nucleus 76 Ge. The Majorana Demonstrator is an array of germanium detectors deployed with the aim of implementing background reduction techniques suitable for a tonne scale 76 Ge-based search (the LEGEND collaboration). In the Demonstrator, germanium detectors operate in an ultra-pure vacuum cryostat at 80 K. One special challenge of an ultra-pure environment is to develop reliable cables, connectors, and electronics that do not significantly contribute to the radioactive background of the experiment. This paper highlights the experimental requirements and how these requirements were met for the Majorana Demonstrator, including plans to upgrade the wiring for higher reliability in the summer of 2018. Also described are requirements for LEGEND R&D efforts underway to meet these additional requirements

74 ATOMIC AND MOLECULAR PHYSICS↗