Search NASA⌕ Search

Engineering topics

Hensel, Steve J.

Publications and source records attributed to Hensel, Steve J..

3013 Surveillance Program Interim Summary Report (FY16-FY21)

The K-Area Documented Safety Analysis (DSA) requires the facility participate in the SRS Site Surveillance Program as a part of Shipping Package Qualification and Storage Surveillance Program. The Site Surveillance Program outlines activities for field surveillance and laboratory tests that demonstrate the 3013 containers meet the functional performance requirements described in the DSA. The SRS Surveillance Program also supports the complex-wide Integrated Surveillance Program (ISP) for 3013 containers in accordance with DOESTD-3013. The purpose of this report is to provide a summary of the SRS portion of the surveillance program activities from FY16 through FY21 and formally communicate the interpretation of these results by the Surveillance Program Authority (SPA).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Selection of 3013 Containers for Field Surveillance (FY 2021 Update)

This Update is the ninth in a series of reports that document the binning and sample selection of 3013 containers for the Field Surveillance program as part of the Integrated Surveillance Program. The last Update was in 2016. This Update documents changes to the binning and changes to the random and engineering judgment samples since 2016. This Update also documents field surveillance activities since 2016 and describes plans to complete random sampling in 2025. In addition, this Update describes a new effort to collect surveillance data as part of down blending operations and updates assumptions about Advanced Recovery and Integrated Extraction System (ARIES) 3013 containers.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Pressurization Analysis for Heating of a Screw Top Utility Can Loaded With Plutonium Oxide Powder by a 1273 K Fire

The documented safety analysis for the Savannah River National Laboratory (SRNL) evaluates the consequences of a postulated 1273 K fire in a glovebox. The radiological dose consequences for a pressurized release of plutonium oxide powder during such a fire depend on the maximum pressure that is attained inside the oxide storage containers. The oxide storage configuration selected for analysis is can/bag/can, comprised of oxide powder inside an 8.38 × 10 -6 m 3 stainless steel B vial inside 0.006 kg of polyethylene bagging inside a one-quart screw top utility can of the type commonly used to package solvents or rubber cements. To enable evaluation of the dose consequences, temperature and pressure transients have been calculated for exposure of a typical set of storage containers to the fire. The pressurization analysis credits venting to and from the B vial but does not credit venting or leakage from the can. Due to the low rate of venting from the B vial into the can gas space, the can pressure is nearly independent of the B vial pressure. Calculated maximum pressures are compared to the utility can burst pressure. In lieu of a structural analysis of the utility cans, burst pressures and leakage rates were measured using compressed nitrogen gas. The measured gauge burst pressure was 0.250 ± 0.043 MPa. The measured burst pressures are lower than the calculated maximum pressure due to fire exposure, indicating that the utility cans could burst during exposure to a 1273 K fire.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Analysis of Venting of a Resin Slurry

A resin slurry venting analysis was conducted to address safety issues associated with over-pressurization of ion exchange columns used in the plutonium uranium redox extraction (PUREX) process at the U. S. Department of Energy’s (DOE’s) Savannah River Site (SRS). If flow to these columns were inadvertently interrupted, an exothermic runaway reaction could occur between the ion exchange resin and the nitric acid used in the feed stream. The nitric acid-resin reaction generates significant quantities of noncondensable gases, which would pressurize the column. To prevent the column from rupturing during such events, rupture disks are installed on the column vent lines. The venting analysis models accelerating rate calorimeter (ARC) tests and data from tests that were performed in a vented test vessel with a rupture disk. The tests showed that the pressure inside the test vessel continued to increase after the rupture disk opened, though at a slower rate than prior to the rupture. The increase in the vessel pressure is modeled as a transient phenomenon associated with expansion of the resin slurry/gas mixture upon rupture of the disk. It is postulated that the maximum pressure at the end of this expansion is limited by energy minimization to approximately 1.5 times the rupture disk burst pressure. The magnitude of this pressure increase is consistent with the measured pressure transients. The results of this analysis demonstrate the need to allow for a margin between the design pressure and the rupture disk burst pressure in similar applications.

42 ENGINEERING↗

Gas composition observed by destructive examination of 3013 containers

The Department of Energy’s Integrated Surveillance and Monitoring Program implements requirements to measure gas pressure and gas composition during destructive examination of 3013 containers as required by DOE’s 3013 Standard. Gas pressures and gas compositions measured by the Program during destructive examination of 3013 containers from 2007 to 2017 are reported here. The maximum gas pressure within the population of containers that have undergone destructive examination was 299 kPa (43.4 psia) and this container had 0.52 wt% moisture which is higher than the Standard allows. The majority of containers have essentially no gas pressurization. Hydrogen was quantifiable above the measurement uncertainty in less than half (47 out of 114) of the containers that have undergone destructive examination. The amount of hydrogen that is generated within the sealed 3013 containers is always less than the amount predicted by the 3013 Standard’s pressure equation with the maximum observed hydrogen fraction (observed moles of hydrogen/predicted moles of hydrogen) of 0.18. It is recommended that for the purposes of calculating a maximum hydrogen pressure using the 3013 equation, a correction to the amount of hydrogen produced from decomposition of the water be incorporated. The pressure (or moles) of H 2 should be reduced by multiplying by a hydrogen fraction as described in the text. Helium and nitrogen are the other major constituents. Oxygen which is initially present in nearly all of the containers undergoing destructive examination was consumed to low values in all cases. The highest observed oxygen concentration was 1.7%, and in this case the H 2 concentration was essentially zero. Other minor gases observed in some cases included CO 2 with maximum content of 3.5%, CO with maximum content of 0.8%, N 2 O with maximum content of 1.4%, and CH 4 with maximum content of 0.4%.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Benchmarking of Improved DPAC Transient Deflagration Analysis Code

The deflagration pressure analysis code (DPAC) has been upgraded for use in modeling hydrogen deflagration transients. The upgraded code is benchmarked using data from vented hydrogen deflagration tests conducted at the HYDRO-SC Test Facility at the University of Pisa. DPAC originally was written to calculate peak pressures for deflagrations in radioactive waste storage tanks and process facilities at the Savannah River Site. Upgrades include the addition of a laminar flame speed correlation for hydrogen deflagrations and a mechanistic model for turbulent flame propagation, incorporation of inertial effects during venting, and inclusion of the effect of water vapor condensation on vessel walls. In addition, DPAC has been coupled with chemical equilibrium with applications (CEA), a NASA combustion chemistry code. The deflagration tests are modeled as end-to-end deflagrations. As a result, the improved DPAC code successfully predicts both the peak pressures during the deflagration tests and the times at which the pressure peaks.

42 ENGINEERING↗

Analysis of Powder Airborne Release Fractions for Vessel Ruptures

The Department of Energy handbook for airborne releases from nonreactor nuclear facilities bases its bounding airborne release fraction (ARF) for pressurized powders on tests conducted at Pacific Northwest Laboratory (PNL). An analysis is presented that correlates the ARF from these tests. The amount of powder that becomes airborne is correlated in terms of an adjusted airborne release fraction (AARF) equal to the product of the powder entrainment from the powder bed and the ratio of the total vessel volume to the volume occupied by the powder bed. Powder entrainments and release fractions at low pressures are correlated using a fluidized bed analogy. The analysis shows that the entrainment is enhanced by a sonic shock if the pressure prior to the rupture exceeds approximately 33 psig. A secondary, three-dimensional shock is predicted to occur at an initial pressure of approximately 332 psig. A correlation based on this analysis is used to predict the ARF for ruptures of vessels containing plutonium oxide. It is assumed that the oxide is pressurized by hydrogen that is radiolytically generated from adsorbed moisture.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Flammability Analysis For Actinide Oxides Packaged In 9975 Shipping Containers

Packaging options are evaluated for compliance with safety requirements for shipment of mixed actinide oxides packaged in a 9975 Primary Containment Vessel (PCV). Radiolytic gas generation rates, PCV internal gas pressures, and shipping windows (times to reach unacceptable gas compositions or pressures after closure of the PCV) are calculated for shipment of a 9975 PCV containing a plastic bottle filled with plutonium and uranium oxides with a selected isotopic composition. G-values for radiolytic hydrogen generation from adsorbed moisture are estimated from the results of gas generation tests for plutonium oxide and uranium oxide doped with curium-244. The radiolytic generation of hydrogen from the plastic bottle is calculated using a geometric model for alpha particle deposition in the bottle wall. The temperature of the PCV during shipment is estimated from the results of finite element heat transfer analyses.

42 ENGINEERING↗

Benchmarking Of Improved DPAC Transient Deflagration Analysis Code

The transient deflagration code DPAC (Deflagration Pressure Analysis Code) has been upgraded for use in modeling hydrogen deflagration transients. The upgraded code is benchmarked using data from vented hydrogen deflagration tests conducted at the HYDRO-SC Test Facility at the University of Pisa. DPAC originally was written to calculate peak deflagration pressures for deflagrations in radioactive waste storage tanks and process facilities at the Savannah River Site. Upgrades include the addition of a laminar flame speed correlation for hydrogen deflagrations and a mechanistic model for turbulent flame propagation, incorporation of inertial effects during venting, and inclusion of the effect of water vapor condensation on vessel walls. In addition, DPAC has been coupled with CEA, a NASA combustion chemistry code. The deflagration tests are modeled as end-to-end deflagrations. The improved DPAC code successfully predicts both the peak pressures during the deflagration tests and the times at which the pressure peaks.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗