Benchmark for evaluation and validation of reactor simulations (BEAVRS)

Advances in parallel computing have made possible the development of high-fidelity tools for the design and analysis of nuclear reactor cores, and such tools require extensive verification and validation. This paper introduces BEAVRS, a new multi-cycle full-core Pressurized Water Reactor (PWR) depletion benchmark based on two operational cycles of a commercial nuclear power plant that provides a detailed description of fuel assemblies, burnable absorbers, in-core fission detectors, core loading patterns, and numerous in-vessel components. This benchmark enables analysts to develop extremely detailed reactor core models that can be used for testing and validation of coupled neutron transport, thermal-hydraulics, and fuel isotopic depletion. The benchmark also provides measured reactor data for Hot Zero Power (HZP) physics tests, boron letdown curves, and three-dimensional in-core flux maps from fifty-eight instrumented assemblies. Initial comparisons between calculations performed with MIT's OpenMC Monte Carlo neutron transport code and measured cycle 1 HZP test data are presented, and these results display an average deviation of approximately 100 pcm for the various critical configurations and control rod worth measurements. Computed HZP radial fission detector flux maps also agree reasonably well with the available measured data. All results indicate that this benchmark will be extremely useful in validation of coupled-physics codes and uncertainty quantification of in-core physics computational predictions. The detailed BEAVRS specification and its associated data package is hosted online at the MIT Computational Reactor Physics Group web site (http://crpg.mit.edu/), where future revisions and refinements to the benchmark specification will be made publicly available. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Description and Sensitivity Analysis of the SOLSE/LORE-2 and SAGE III Limb Scattering Ozone Retrieval Algorithms

The SOLSE (Shuttle Ozone Limb Sounding Experiment) and LORE (Limb Ozone Retrieval Experiment) instruments are scheduled for reflight on Space Shuttle flight STS-107 in July 2002. In addition, the SAGE III (Stratospheric Aerosol and Gas Experiment) instrument will begin to make limb scattering measurements during Spring 2002. The optimal estimation technique is used to analyze visible and ultraviolet limb scattered radiances and produce a retrieved ozone profile. The algorithm used to analyze data from the initial flight of the SOLSE/LORE instruments (on Space Shuttle flight STS-87 in November 1997) forms the basis of the current algorithms, with expansion to take advantage of the increased multispectral information provided by SOLSE/LORE-2 and SAGE III. We also present detailed sensitivity analysis for these ozone retrieval algorithms. The primary source of ozone retrieval error is tangent height misregistration (i.e., instrument pointing error), which is relevant throughout the altitude range of interest, and can produce retrieval errors on the order of 10-20 percent due to a tangent height registration error of 0.5 km at the tangent point. Other significant sources of error are sensitivity to stratospheric aerosol and sensitivity to error in the a priori ozone estimate (given assumed instrument signal-to-noise = 200). These can produce errors up to 10 percent for the ozone retrieval at altitudes less than 20 km, but produce little error above that level.

Loughman, R.↗

The GPS radio occulation technique

Radio occultation observations represent a planetary-scale optics experiment in which the atmosphere acts as a lens and alters the propagation velocity and paths of microwave signals passing through it.

pressure geopotential height water vapor GPS clima↗

Micro-optics technology and sensor systems applications

The current generation of electro-optical sensors utilizing refractive and reflective optical elements require sophisticated, complex, and expensive designs. Advanced-technology-based electro-optical sensors of minimum size and weight require miniaturization of optical, electrical, and mechanical devices with an increasing trend toward integration of various components. Micro-optics technology has the potential in a number of areas to simplify optical design with improved performance. This includes internally cooled apertures, hybrid optical design, microlenses, dispersive multicolor microlenses, active dither, electronically controlled optical beam steer, and microscopic integration of micro-optics, detectors, and signal processing layers. This paper describes our approach to the development of micro-optics technology with our main emphasis for sensors applications.

Gal, George↗

Measurements of microlens performance

We present results of laboratory evaluations of several microlens types that have been designed and fabricated at the Lockheed Research and Development Division. The microlenses include wideband and dispersive types, in isolation and in arrays, and fabricated with binary or grayscale methods. Different lens pixel geometries are considered, including square, hexagonal, and skewed microlenses. We describe our micro-optics laboratory testbed which has been designed for the evaluation of individual lenslets or 2D arrays at selected spectral wavelengths. Measurement capabilities include focal length, point-spread functions, wavefront quality, and modulation transfer functions. Our present effort focuses on the results of point spread function measurements and their comparison with design predictions.

Shough, D.↗

Theory of dispersive microlenses

A dispersive microlens is a miniature optical element which simultaneously focuses and disperses light. Arrays of dispersive mircolenses have potential applications in multicolor focal planes. They have a 100 percent optical fill factor and can focus light down to detectors of diffraction spot size, freeing up areas on the focal plane for on-chip analog signal processing. Use of dispersive microlenses allows inband color separation within a pixel and perfect scene registration. A dual-color separation has the potential for temperature discrimination. We discuss the design of dispersive microlenses and present sample results for efficient designs.

Herman, B.↗

Water vapor measurements in the 0.94 micron absorption band - Calibration, measurements and data applications

This paper describes methods and presents results for sensing the columnar content of atmospheric water vapor via differential solar transmission measurements in and adjacent to the 0.94-micron water-vapor absorption band. Calibration and measurement techniques are presented for obtaining the water vapor transmission from the radiometer measurements. Models are also presented for retrieving the columnar water vapor amount from the estimated transmission. Example retrievals are presented for radiometer measurements made during the 1986 Arizona Monsoon Season to track temporal variations in columnar water vapor amount.

Reagan, J. A.↗

An extension to the Chahine method of inverting the radiative transfer equation

An extension of the Chahine relaxation method (1970) for inverting the radiative transfer equation is presented. This method is superior to the original method in that it takes into account in a realistic manner the shape of the kernel function, and its extension to nonlinear systems is much more straightforward. A comparison of the new method with a matrix method due to Twomey (1965), in a problem involving inference of vertical distribution of ozone from spectroscopic measurements in the near ultraviolet, indicates that in this situation this method is stable with errors in the input data up to 4%, whereas the matrix method breaks down at these levels. The problem of non-uniqueness of the solution, which is a property of the system of equations rather than of any particular algorithm for solving them, remains, although it takes on slightly different forms for the two algorithms.

Twomey, S.↗