Search NASA⌕ Search

Engineering topics

Herrera, Jeremy

Publications and source records attributed to Herrera, Jeremy.

Catalytic Removal of Oxygen and Pollutants in Exhaust Gases from Pressurized Oxy-Combustors

The primary goal of this project was to develop and validate advanced catalytic materials and systems for purifying the flue gas generated from pressurized oxy-combustors in an effort to achieve the purity specifications of carbon dioxide (CO 2 ) streams required by the U.S. Department of Energy (USDOE) for application in enhanced oil recovery. The technology has shown great potential for improving energy efficiency, simplifying process complexity, and lowering costs compared with current state-of-the-art oxy-combustion flue gas purification technologies. Laboratory studies were conducted for the development, characterization, and screening of metal catalysts for residual oxygen (O 2 ) reduction with methane (CH 4 ) and multifunctional carbon catalysts for combined nitrogen oxides (NO x ), sulfur oxides (SO x ), and mercury (Hg) removal. A bench-scale reverse-flow fixed-bed (RFFB) reactor and a trickle-bed direct-contact cooler (DCC) reactor capable of treating 15 standard liters per min of pressurized oxy-combustion flue gas were fabricated and tested with both a simulated flue gas in the laboratory and a slipstream of actual flue gas at a 100 kW th Staged, Pressurized Oxy-Combustion (SPOC) pilot facility. Process simulation and techno-economic studies were performed to evaluate the energy efficiency and cost of the developed catalytic flue gas purification process integrated into a conceptual 550-MWe SPOC power plant. The goal and objectives of the project have been successfully accomplished. A cobalt-manganese (CoMn) oxide catalyst was developed and demonstrated in the bench-scale RFFB reactor in either a reverse-flow or one-direction flow mode of operation that met the success criterion of performance for residual O 2 reduction. A carbon catalyst was developed and demonstrated in the bench-scale DCC reactor that met the success criterion of performance for combined NO x /SO x /Hg removal. Slipstream testing of the integrated DCC-RFFB system at the SPOC pilot facility demonstrated stable operation and verified the superior performance obtained in the laboratory. The techno-economic analysis showed that a 550-MWe SPOC plant integrated with the catalytic flue gas purification process would result in costs of electricity of $\$$96.94/MWh and $\$$80.27/MWh in two assessed cases compared with $\$$91.07/MWh reported for the USDOE’s Current Technology Case, which generated only a partially pure CO 2 stream. On the basis of the results and findings from this project, scale-up studies of materials production and system demonstration and optimization studies of reactors and processes are recommended at the next stage of technology development.

20 FOSSIL-FUELED POWER PLANTS↗

Numerical Simulation of AFP Nip Point Temperature Prediction for Complex Geometries

Material placement at the ideal nip point temperature over complex surfaces with uniformity across the width of the compaction rollers results in optimized part properties for Automated Fiber Placement (AFP) processes. However, current AFP systems utilize heat control models and methodologies, based on multiple process parameters such as feed-rate and orientation, that are mostly open-loop. Here, infrared (IR) heater input is calibrated as a function of process parameters during machine qualification. This work presents a numerical simulation to predict arrayed-infrared (AIR) emitter radiation onto a substrate that includes view factor implementation, IR radiative heat flow calculation, energy rate balance, and a transient heat transfer model. The purpose of this numerical model is to predict nip point temperature on complex surfaces, serving as a baseline for a new arrayed-infrared (AIR) thermoset heater to improve AFP process control. It is anticipated that this simulation will accurately control the temperature for high-speed AFP layup of complex geometries. An anticipated result of an AIR heater system is that material calibration and testing will be reduced as temperature is instantaneously monitored and controlled. Therefore, temperature across the roller width will be uniform during placement of complex parts, independent of their geometry.

Xia, Kaishu↗