Search NASA⌕ Search

Engineering topics

Hertz, Edward

Publications and source records attributed to Hertz, Edward.

X-Ray Performance of Critical-angle Transmission Grating Prototypes for the Arcus Mission

Arcus is a proposed Explorer Class soft X-ray grating spectrometer. It aims to explore cosmic feedback by mapping hot gases within and between galaxies and galaxy clusters and characterizing jets and winds from supermassive black holes and to investigate the dynamics of protoplanetary disks and stellar accretion. Arcus features 12 m focal-length grazing-incidence silicon pore optics (SPO) developed for the Athena mission. Critical-angle transmission (CAT) gratings efficiently disperse high diffraction orders onto CCDs. We report new and improved X-ray performance results for Arcus-like CAT gratings, including a record resolving power for two coaligned CAT gratings. Multiple Arcus prototype grating facets were illuminated by an SPO at the PANTER facility. The facets consist of 32 × 32.5 mm 2 patterned silicon membranes, bonded to metal frames. The bonding angle is adjusted according to the measured average tilt angle of the grating bars in the membrane. Two simultaneously illuminated facets show a minor broadening of the Al-K α doublet in the 18th and 21st orders with the best-fit record effective resolving power of ${R}_{G}\approx {1.3}_{-0.5}^{+\infty }\times {10}^{4}$ (3σ), about three to four times the Arcus requirement. We measured the diffraction efficiency of quasi-fully illuminated gratings at O-K wavelengths in orders 4–7 in an Arcus-like configuration and compare results with synchrotron spot measurements. After corrections for geometrical effects and bremsstrahlung continuum, we find agreement between full and spot illumination at the two different facilities, as well as with the models used for Arcus effective area predictions. We find that these flight-like gratings meet the diffraction efficiency and greatly exceed the resolving power Arcus requires.

79 ASTRONOMY AND ASTROPHYSICS↗

Marshall Grazing Incidence X-Ray Spectrometer (MaGIXS)

Outline: Scientific motivation for MaGIXS (Marshall Grazing Incidence X-ray Spectrometer) - Demonstrate sensitivity of MaGIXS to determine high temperature plasma; Instrument design - Challenges involved; Instrument status - alignment and calibration.

Athiray, P. S.↗

On the Development of the Marshall Grazing Incidence X-ray Spectrograph (MaGIXS) Mirrors

The Marshall Grazing Incidence X-ray Spectrograph (MaGIXS) is a sounding rocket experiment that will obtain spatially resolved soft X-ray spectra of the solar corona from 0.5 - 2 keV. The optical system comprises a Wolter-I telescope mirror, a slit spectrograph, and a CCD camera. The spectrograph has a finite conjugate paraboloid pair, which re-images the slit, and a varied line-space planar reflection grating. Both the Wolter-I mirror and paraboloid pair are being fabricated at the NASA Marshall Space Flight Center (MSFC), using nickel replication. The MaGIXS mirror mandrels have been diamond turned, polished, and have yielded a set of engineering mirrors. Unlike other grazing incidence instruments, such as FOXSI, ART-XC, and IXPE, the MaGIXS prescriptions have large departure from a cone. This property exacerbates challenges with conventional lap polishing techniques and interferometric metrology. Here we discuss the progression of the optical surfaces of the mandrels through lap polishing, X-ray data from the replicated shells obtained in the MSFC Stray Light Facility (SLF), and our transition to using the ZEEKO computer numerical controlled (CNC) polisher for figure correction.

Champey, Patrick↗

On the Alignment and Focusing of the Marshall Grazing Incidence X-ray Spectrometer (MaGIXS)

The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) is a NASA sounding rocket instrument that is designed to observe soft X-ray emissions from 24 - 6.0 A (0.5 - 2.0 keV energies) in the solar atmosphere. For the rst time, high-temperature, low-emission plasma will be observed directly with 5 arcsecond spatial resolution and 22 mA spectral resolution. The unique optical design consists of a Wolter - I telescope and a 3-optic grazing- incidence spectrometer. The spectrometer utilizes a nite conjugate mirror pair and a blazed planar, varied line spaced grating, which is directly printed on a silicon substrate using e-beam lithography. The grating design is being nalized and the grating will be fabricated by the Massachusetts Institute of Technology (MIT) and Izentis LLC. Marshall Space Flight Center (MSFC) is producing the nickel replicated telescope and spectrometer mirrors using the same facilities and techniques as those developed for the ART-XC and FOXSI mirrors. The Smithsonian Astrophysical Observatory (SAO) will mount and align the optical sub-assemblies based on previous experience with similar instruments, such as the Hinode X-Ray Telescope (XRT). The telescope and spectrometer assembly will be aligned in visible light through the implementation of a theodolite and reference mirrors, in addition to the centroid detector assembly (CDA) { a device designed to align the AXAF-I nested mirrors. Focusing of the telescope and spectrometer will be achieved using the X-ray source in the Stray Light Facility (SLF) at MSFC. We present results from an alignment sensitivity analysis performed on the on the system and we also discuss the method for aligning and focusing MaGIXS.

solar↗