Search NASA⌕ Search

Engineering topics

Herwig, Kenneth W

Publications and source records attributed to Herwig, Kenneth W.

At least 19 records

Overview of the conceptual design of the future VENUS beamline at the Spallation Neutron Source

VENUS will be a world-class neutron-imaging instrument that will uniquely utilize the Spallation Neutron Source (SNS) time-of-flight (TOF) capabilities to measure and characterize objects across several length scales (mm to m). When completed, VENUS will provide academia, industry and government laboratories with the opportunity to advance scientific research in areas such as energy, materials, additive manufacturing, geosciences, transportation, engineering, plant physiology, biology, etc. It is anticipated that a good portion of the VENUS user community will have a strong engineering/industrial research focus. Installed at Beamline 10 (BL10), VENUS will be a 25-m neutron imaging facility with the capability to fully illuminate (i.e., umbra illumination) a 20 cm x 20 cm detector area. The design allows for a 28 cm x 28 cm field of view when using the penumbra to 80% of the full illumination flux. A sample position at 20 m will be implemented for magnification measurements. The optical components are comprised of a series of selected apertures, T0 and bandwidth choppers, beam scrapers, a fast shutter to limit sample activation, and flight tubes filled with Helium. Techniques such as energy selective, Bragg edge and epithermal imaging will be available at VENUS

instrument design↗

Overview of the Neutron Radiography and Computed Tomography at the Oak Ridge National Laboratory and Applications

The Oak Ridge National Laboratory (ORNL) Neutron Sciences Directorate (NScD) has installed a neutron imaging (NI) beam line at the High Flux Isotope Reactor (HFIR) cold guide hall. The CG-1D beam line produces cold neutrons for a broad range of user research spanning from engineering to material research, additive manufacturing, vehicle technologies, archaeology, biology, and plant physiology. Recent efforts have focused on increasing flux and spatial resolution. A series of selected engineering applications is presented here. Historically and for more than four decades, neutron imaging (NI) facilities have been installed exclusively at continuous (i.e. reactor-based) neutron sources rather than at pulsed sources. This is mainly due to (1) the limited number of accelerator-based facilities and therefore the fierce competition for beam lines with neutron scattering instruments, (2) the limited flux available at accelerator-based neutron sources and finally, (3) the lack of high efficiency imaging detector technology capable of time-stamping pulsed neutrons with sufficient time resolution. Recently completed high flux pulsed proton-driven neutron sources such as the ORNL Spallation Neutron Source (SNS) at ORNL and the Japanese Spallation Neutron Source (JSNS) of the Japan Proton Accelerator Research Complex (J-PARC) in Japan produce high neutron fluxes that offer new and unique opportunities for NI techniques. Pulsed-based neutron imaging facilities RADEN and IMAT are currently being built at J-PARC and the Rutherford National Laboratory in the U.K., respectively. ORNL is building a pulsed neutron imaging beam line called VENUS to respond to the U.S. based scientific community. A team composed of engineers, scientists and designers has developed a conceptual design of the future VENUS imaging instrument at the SNS.

additive manufacturing↗

Optimizing moderator dimensions for neutron scattering at the spallation neutron source

In this work, we investigate the effect of neutron moderator dimensions on the performance of neutron scattering instruments at the Spallation Neutron Source (SNS). In a recent study of the planned second target station at the SNS facility, we have found that the dimensions of a moderator play a significant role in determining its surface brightness. A smaller moderator may be significantly brighter over a smaller viewing area. One of the immediate implications of this finding is that for modern neutron scattering instrument designs, moderator dimensions and brightness have to be incorporated as an integrated optimization parameter. Here, we establish a strategy of matching neutron scattering instruments with moderators using analytical and Monte Carlo techniques. In order to simplify our treatment, we group the instruments into two broad categories: those with natural collimation and those that use neutron guide systems. For instruments using natural collimation, the optimal moderator selection depends on the size of the moderator, the sample, and the moderator brightness. The desired beam divergence only plays a role in determining the distance between sample and moderator. For instruments using neutron optical systems, the smallest moderator available that is larger than the entrance dimension of the closest optical element will perform the best (assuming, as is the case here that smaller moderators are brighter)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Instrument performance study on the short and long pulse options of the second Spallation Neutron Source target station

The Spallation Neutron Source (SNS) facility at the Oak Ridge National Laboratory is designed with an upgrade option for a future low repetition rate, long wavelength second target station. This second target station is intended to complement the scientific capabilities of the 1.4 MW, 60 Hz high power first target station. Two upgrade possibilities have been considered, the short and the long pulse options. In the short pulse mode, proton extraction occurs after the pulse compression in the accumulator ring. The proton pulse structure is thus the same as that for the first target station with a pulse width of ∼0.7 μs. In the long pulse mode, protons are extracted as they are produced by the linac, with no compression in the accumulator ring. The time width of the uncompressed proton pulse is ∼1 ms. This difference in proton pulse structure means that neutron pulses will also be different. Neutron scattering instruments thus have to be designed and optimized very differently for these two source options which will directly impact the overall scientific capabilities of the SNS facility. In order to assess the merits of the short and long pulse target stations, we investigated a representative suit of neutron scattering instruments and evaluated their performance under each option. Our results indicate that the short pulse option will offer significantly better performance for the instruments and is the preferred choice for the SNS facility.

43 PARTICLE ACCELERATORS↗

IBIS: An inverse geometry Brillouin inelastic neutron spectrometer for the SNS

The high power target station at the Spallation Neutron Source (SNS) currently has about 20 completed neutron scattering instruments. With a broad coverage of the momentum transfer (Q)-energy (E) space, these instruments serve an extensive user community. In an effort to further expand the scientific capabilities of the SNS instrument suites, we propose a low background, inverse geometry Brillouin inelastic spectrometer for the SNS which will expand the Q-E coverage of the current instrument suite and facilitate the study of inelastic and quasi-elastic scatterings at low Q values. The possible location for the proposed instrument is either beamline 8 which views the decoupled water moderator, or beamline 14A, which views a cold, coupled super critical hydrogen moderator. The instrument parameters, optimizations, and performances at these two beamline locations are discussed.

43 PARTICLE ACCELERATORS↗

Polarized Neutron in Structural Biology Present and Future Outlook

Hydrogen has a strong polarization-dependent neutron scattering cross section. This property has been exploited in the study of soft matters, especially biological macromolecules. When a polarized neutron beam is scattered off a polarized hydrogenous sample, the otherwise large hydrogen incoherent cross section is drastically reduced while the coherent signal is significantly increased. Past experiments have demonstrated the potentials and benefits of polarized neutron scattering from soft materials. The main technical challenge of polarized neutron scattering from biological matters lies at sample polarization. Dynamic nuclear polarization is a proven yet rather sophisticated technique. Its complexity is one of the main reasons for the technique's slow adoption. The future of polarized neutron scattering in biology may rest largely in neutron protein crystallography. Polarization of protein crystals is much easier to accomplish, since protein crystals are typically rather small (<<1 mm) and only require small and easy- to-operate polarization apparatuses. In addition, the high resolution nature of neutron protein crystallography means that we will be able to study individual atoms using the polarized neutron scattering technique.

Zhao, Jinkui↗

The Dynamics of 1, 3 diphenylpropane Tethered to the Interior Pore Surfaces of MCM-41

The diffusive motions of covalently tethered 1, 3 diphenylpropane (DPP) via a silyl-aryl-ether linkage in the mesopores of MCM-41 were studied by quasielastic neutron scattering. The geometric effect of pore radius was investigated with samples having pores that ranged from 1.6 to 3.0 nm in diameter and highest achievable DPP grafting density. The effect of molecular crowding was investigated in 3.0 nm diameter pores for surface coverage ranging from 0.60 to 1.61 DPP/nm2. Temperature dependence was determined for large pore diameter samples from 240 K to 370 K. As the DPP molecules remain attached over this entire temperature range, data were analyzed in terms of a model of localized diffusion inside a sphere. Only the motions of the DPP hydrogen atoms were considered because of the high sensitivity of neutron scattering to the presence of hydrogen. As atoms far from the attachment point have a greater range of motion than those nearer the tether, the radius of the sphere limiting the motion of individual hydrogen atoms was allowed to increase based on the atom s distance from the tether point. Both smaller pore diameters and higher DPP surface coverage resulted in larger amplitude motion while the diffusion coefficient was greatest in the largest pores at highest surface coverage. These observations support a model where the DPP molecules prefer an orientation allowing close proximity to the MCM-41 pore surface and are forced into the pore interior by either the steric effect of small pore diameter or by increased competition for surface area at high molecule surface coverage.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Contrast variation in spin-echo small angle neutron scattering

The principle of using contrast variation spin-echo small angle neutron scattering (SESANS) technique for colloidal structural investigation is discussed. Based on the calculations of several model systems, we find that the contrast variation SESANS technique is not sensitive in detecting the structural characteristics of colloidal suspensions consisting of particles with uniform scattering length density profiles. However, its capability of resolving the structural heterogeneity, at both intra- and inter-colloidal length scales, is clearly demonstrated. The prospect of using this new technique to investigate the structural information that is difficult to be probed by other ways is also explored.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Structural Response of Polyelectrolyte Dendrimer toward the Molecular Protonation: The Inconsistence Revealed by SANS and NMR

Polyamidoamine (PAMAM) dendrimers and their charged state in deuterium oxide have been investigated with diffusion NMR and small angle neutron scattering (SANS) techniques. NMR measurement suggests that, upon increasing the molecular protonation by progressive acidification of solutions, significant variation of hydrodynamic radius, calculated by the Stokes-Einstein relation with given surface condition, is observed upon increasing the molecular protonation. However, comparative SANS experiment indicates little dependence of dendrimer global size, in terms of radius of gyration, on molecular protonation. This observed inconsistence indicates the necessity of incorporating the effect of molecular interface modification by dressed counterion, when dynamical measurements are used for determination the structural characteristics of ionic soft colloids even in a dilute enough suspension.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Neutrons for Catalysis: A Workshop on Neutron Scattering Techniques for Studies in Catalysis

This report summarizes the Workshop on Neutron Scattering Techniques for Studies in Catalysis, held at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) on September 16 and 17, 2010. The goal of the Workshop was to bring experts in heterogeneous catalysis and biocatalysis together with neutron scattering experimenters to identify ways to attack new problems, especially Grand Challenge problems in catalysis, using neutron scattering. The Workshop locale was motivated by the neutron capabilities at ORNL, including the High Flux Isotope Reactor (HFIR) and the new and developing instrumentation at the SNS. Approximately 90 researchers met for 1 1/2 days with oral presentations and breakout sessions. Oral presentations were divided into five topical sessions aimed at a discussion of Grand Challenge problems in catalysis, dynamics studies, structure characterization, biocatalysis, and computational methods. Eleven internationally known invited experts spoke in these sessions. The Workshop was intended both to educate catalyst experts about the methods and possibilities of neutron methods and to educate the neutron community about the methods and scientific challenges in catalysis. Above all, it was intended to inspire new research ideas among the attendees. All attendees were asked to participate in one or more of three breakout sessions to share ideas and propose new experiments that could be performed using the ORNL neutron facilities. The Workshop was expected to lead to proposals for beam time at either the HFIR or the SNS; therefore, it was expected that each breakout session would identify a few experiments or proof-of-principle experiments and a leader who would pursue a proposal after the Workshop. Also, a refereed review article will be submitted to a prominent journal to present research and ideas illustrating the benefits and possibilities of neutron methods for catalysis research.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A time-of-flight backscattering spectrometer at the Spallation Neutron Source, BASIS

We describe the design and current performance of the backscattering silicon spectrometer (BASIS), a time-of-flight backscattering spectrometer built at the spallation neutron source (SNS) of the Oak Ridge National Laboratory (ORNL). BASIS is the first silicon-based backscattering spectrometer installed at a spallation neutron source. In addition to high intensity, it offers a high-energy resolution of about 3.5 {mu}eV and a large and variable energy transfer range. These ensure an excellent overlap with the dynamic ranges accessible at other inelastic spectrometers at the SNS.

43 PARTICLE ACCELERATORS↗

Scattering functions of Platonic solids

The single-particle small-angle scattering properties of five Platonic solids, including the tetrahedron, hexahedron, octahedron, dodecahedron and icosahedron, are systematically investigated. For each given geometry, the Debye spatial autocorrelation function, pair distance distribution function and intraparticle structure factor (form factor) are calculated and compared with the corresponding scattering function of a spherical reference system. From the theoretical models, the empirical relationship between the dodecahedral and icosahedral structural characteristics and those of the equivalent spheres is found. Moreover, the single-particle scattering properties of icosahedral and spherical shells with identical volume are investigated, and the prospect of using different data analysis approaches to explore their structural differences is presented and discussed.

36 MATERIALS SCIENCE↗

pH Responsiveness of Polyelectrolyte Dendrimers: A Dynamical Perspective

Quasielastic neutron scattering (QENS) experiments were carried out to investigate the internal dynamics of aqueous (D2O) G5 PAMAM dendrimer solutions as a function of molecular protonation at room temperature. The localized motion was clearly exhibited in data analysis by being separated from the global translational diffusion. Our results unambiguously point out that with the molecular charge increased continuously the local motion is stably enhanced. The charge-induced local dynamics of dendrimer segments may correspond to their interaction with the surrounding counterions and water molecules. The outcome may provide significant information for the application of dendrimer-based packages as drug delivery vehicles.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Scattering functions of Platonic solids

In this report the single-particle scattering properties of five Platonic solids, including tetrahedron, hexahedron, octahedron, dodecahedron and icosahedron, are investigated in a systematic manner. For each given geometry, the Debye spatial autocorrelation function (r), pair distance distribution function (PDDF) p (r) and intraparticle structure factor (form factor) P (Q) are respectively calculated and compared to the corresponding scattering function of the spherical referential system. Based on our theoretical models, the empirical relationship between the dodecahedral and icosahedral structural characteristics and those of the equivalent spheres is found. Moreover, the single-particle scattering properties of the icosahedral and the spherical shells with the same volume are further investigated and the prospect of using different data analysis approaches to explore their structural difference is also presented and discussed.

36 MATERIALS SCIENCE↗

Intra-molecular Structural Change of PAMAM Dendrimers in Aqueous Solutions Revealed by Small Angle Neutron Scattering

Small-angle neutron scattering (SANS) experiments were carried out to investigate the structure of aqueous (D2O) G4 PAMAM dendrimer solutions as a function of molecular protonation and dendrimer concentration. Our results indicate unambiguously that, although the radius of gyration RG remains nearly invariant, the dendrimer radial density profile (r) decreases in the dendrimer core with a continuous increase in protonation. This discovery also suggests that RG, which is commonly adopted by numerous simulation and experimental works in describing the global dendrimer size, is not suitable as the index parameter to characterize the dendrimer conformation change. We also found that RG and (r), for dendrimers dissolved in both neutral and acidified solutions, remain nearly constant over the studied concentration range. We further demonstrate that the outcome of the widely used Guinier method is questionable for extracting RG in the concentration range studied. Our results reveal the polymer colloid structural duality as benchmarks for future experimental and theoretical studies and provide a critical step toward understanding drug encapsulation by ionic bonds.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗