Search NASA⌕ Search

Engineering topics

Herzig, Howard

Publications and source records attributed to Herzig, Howard.

Effects of the LDEF orbital environment on the reflectance of optical mirror materials

Specimens of eight different optical mirror materials were flown in low earth orbit as part of the Long Duration Exposure Facility (LDEF) manifest to determine their ability to withstand exposure to the residual atomic oxygen and other environmental effects at those altitudes. Optical thin films of aluminum, gold, iridium, osmium, platinum, magnesium fluoride-overcoated aluminum and reactively deposited, silicon monoxide-protected aluminum, all of which were vacuum deposited on polished fused silica substrates, were included as part of Experiment S0010, Exposure of Spacecraft Coatings. Two specimens of polished, chemical vapor deposited (CVD) silicon carbide were installed in sites available in Experiment A0114, Interaction of Atomic Oxygen with Solid Surfaces at Orbital Altitudes, which included trays in two of the spacecraft bays, one on the leading edge and the other on the trailing edge. One of the silicon carbide samples was located in each of these trays. This paper will compare specular reflectance data from the preflight and postflight measurements made on each of these samples and attempt to explain the changes in light of the specific environments to which the experiments were exposed.

Herzig, Howard↗

Long-duration orbital effects on optical coating materials

We flew specimens of eight different optical coating materials in low earth orbit as part of the Long Duration Exposure Facility manifest to determine their ability to withstand exposure to the residual atomic 0 and other environmental effects at those altitudes. We included samples of Al, Au, Ir, Os, Pt, Al + MgF2, Al + SiO(x), and chemical-vapor-deposited SiC, representing reflective optical applications from the vacuum ultraviolet through the visible portions of the spectrum. We found that the majority of the materials suffered sufficient reflectance degradation to warrant careful consideration in the design of future space-flight instrumentation.

Herzig, Howard↗

Variability in the vacuum-ultraviolet transmittance of magnesium fluoride windows

Sample window materials tested during the development of a domed magnesium fluoride detector window for the Hubble Space Telescope's Imaging Spectrograph are noted to exhibit wide variability in VUV transmittance; a test program was accordingly instituted to maximize a prototype domed window's transmittance. It is found that VUV transmittance can be maximized if the boule from which the window is fashioned is sufficiently large to allow such a component to be cut from the purest available portion of the boule.

Herzig, Howard↗

Optical surface refurbishment in space environment

The potential use of the vacuum environment of space to clean contaminated mirror surfaces or generate Al mirror surfaces with high reflectance in the 80-200-nm region is discussed and illustrated with diagrams and graphs, reviewing previous studies and current experiment proposals. Consideration is given to (1) applying the atomic oxygen plasma environment of LEO to clean coated mirrors and (2) depositing freshly evaporated Al onto a mirror surface in vacuum, providing relatively long periods of high EUV reflectance before oxidation of the surface degrades performance: such a procedure could be performed as a maintenance measure or even incorporated into the design of a space observatory. A free-flying experiment is described which would produce and maintain an Al surface with controlled exposure to OH, H2O, and O2; demonstrate directed-beam Al deposition onto a simulated telescope/spectrometer surface; monitor instrument reflectance/sensitivity over time; and demonstrate in situ refurbishment of the degraded surface.

Heaney, James B.↗

Normal incidence reflectance of ion beam deposited SiC films in the EUV

Results are presented from an experimental investigation of the normal-incidence reflectance at 58.4, 92.0, and 121.6 nm wavelength of 30- and 80-nm-thick SiC films produced by ion-beam deposition on unheated 5 x 5-cm microscope slides. The films were deposited in the 2-m evaporator described by Bradford et al. (1969) with chamber base pressure 1 microtorr, operating pressure 40 microtorr, and a 50-62-mA 750-eV Ar ion beam; the reflectance measurements were obtained in the reflector-monochromator system described by Osantowski (1974). Reflectances of over 30 percent were found at 92 and 121.6 nm, almost equal to those of polished CVD films of SiC and degrading only slightly after aging for 4 months. It is suggested that ion-beam deposition may be the best low-temperature technique for coating EUV optics for space astronomy.

Keski-Kuha, Ritva A. M.↗

Broadband reflectance coatings for vacuum ultraviolet application

An experimental investigation has obtained results indicating that neither LaF3 nor LiYF4 are acceptable alternatives to MgF2 as coatings for vacuum-deposited aluminum mirrors from which high UV reflectance down to 1150 A is required. Nevertheless, LaF3 may prove useful in those specialized applications in which the suppression of lower wavelength emissions, such as the 1216-A hydrogen line, is desirable.

Herzig, Howard↗