Heyser, R. C.

Publications and source records attributed to Heyser, R. C..

Broadband Ultrasonic Transducers

New geometry spreads out resonance region of piezoelectric crystal. In new transducer, crystal surfaces made nonparallel. One surface planar; other, concave. Geometry designed to produce nearly uniform response over a predetermined band of frequencies and to attenuate strongly frequencies outside band. Greater bandwidth improves accuracy of sonar and ultrasonic imaging equipment.

Heyser, R. C.

Two-Element Transducer for Ultrasound

Separation of transmitting and receiving units improves probing of deep tissue. Ultrasonic transducer has dual elements to increase depth at which sonic images are made of biological tissue. Transducer uses separate transmitting and receiving elements, and frequency response of receiving element independently designed to accommodate attenuation of higher frequencies by tissue. New transducer intended for pulse-echo ultrasonic systems in which reflected sound pulses reveal features in tissue.

Lecroissette, D. H.

Containerless-Processing Module

High-temperature, containerless-processing module positions and melts molten glass or metal without contact with container wall. Fluid masses manipulated, stirred, and controlled by acoustic forces. Module provides photographic monitoring and transfer of solidified specimens to storage bins.

Wang, T. G.

Method for shaping and aiming narrow beams

A sonar method and apparatus is discribed which utilizes a linear frequency chirp in a transmitter/receiver having a correlator to synthesize a narrow beamwidth pattern from otherwise broadbeam transducers when there is relative velocity between the transmitter/receiver and the target. The chirp is so produced in a generator in bandwidth, B, and time, T, as to produce a time bandwidth product, TB, that is increased for a narrower angle. A replica of the chirp produced in a generator is time delayed and Doppler shifted for use as a reference in the receiver for correlation of received chirps from targets. This reference is Doppler shifted to select targets preferentially, thereby to not only synthesize a narrow beam but also aim the beam in azimuth and elevation.

Heyser, R. C.

Temperature and frequency dependence of ultrasonic attenuation in selected tissues

Ultrasonic attenuation over the frequency range of 1.5-10 MHz has been measured as a function of temperature for porcine liver, backfat, kidney and spleen as well as for a single specimen of human liver. The attenuation in these excised specimens increases nearly linearly with frequency. Over the temperature range of approximately 4-37 C the attenuation decreases with increasing temperature for most soft tissue studied.

Gammell, P. M.

Tissue identification by ultrasound

The ultrasonic properties of animal and human soft tissue were measured over the frequency range of 1.5 to 10.0 MHz. The method employed a swept-frequency, coherent technique known as time delay spectrometry. Measurements of attenuation versus frequency on liver, backfat, kidney, pancreas, spleen, breast, and other tissue were made. Considerable attention was paid to tissue handling and in determining the effects of fixing on the attenuation of ultrasound in the tissue.

Lecroissette, D. H.

Obtaining a tomographic image from transmission projections

Technique for obtaining tomographic images work directly in signal space and is used to find object configuration by simple summation of density values. Image is reconstructed by precise inverse of scanning. Signal values corresponding to density of projection are added as constant terms along line corresponding to original path between two probes that give rise to that density value.

Heyser, R. C.

Medical ultrasonic tomographic system

An electro-mechanical scanning assembly was designed and fabricated for the purpose of generating an ultrasound tomogram. A low cost modality was demonstrated in which analog instrumentation methods formed a tomogram on photographic film. Successful tomogram reconstructions were obtained on in vitro test objects by using the attenuation of the fist path ultrasound signal as it passed through the test object. The nearly half century tomographic methods of X-ray analysis were verified as being useful for ultrasound imaging.

Heyser, R. C.

A new ultrasonic imaging system using time delay spectrometry

A new method of forming a visual image by ultrasound is described. A shadowgraphic transmission image similar to an X-ray radiograph is produced by the application of a technique known as Time Delay Spectrometry. The system uses a repetitive frequency sweep with a linear relationship between frequency and time and the transmitting and receiving crystal are scanned in raster fashion about the subject. By electronic processing, an image may be built up which represents the energy transmitted through the specimen with a given time delay. An intensity modulated picture encompassing the full shades-of-gray capability of the recording system can be produced. A second type of image showing transmission time through the specimen may also be formed. Brightness changes in the displayed image in this case correspond to changes in the ultrasonic transmission time through the specimen.

Heyser, R. C.

Temperature control system with a pulse width modulated bridge

A temperature control system, which includes a modified wheatstone bridge with a resistive-capacitive (RC) circuit in one leg of the bridge, is disclosed. The RC circuit includes a resistor which provides an effective resistance as a function of its absolute resistance and the on-time to off-time ratio of pulses supplied to a switch connected across it. A sawtooth voltage is produced across the RC circuit. The voltage is compared with the voltage across a temperature sensor with heat being applied during each pulse period portion when the sawtooth voltage exceeds the voltage across the temperature sensor.

Heyser, R. C.

Transmission ultrasonography

Review of the results of the application of an advanced signal-processing technique, called time delay spectrometry, in obtaining soft tissue transmission images by transmission ultrasonography, both in vivo and in vitro. The presented results include amplitude ultrasound pictures and phase ultrasound pictures obtained by this technique. While amplitude ultrasonographs of tissue are closely analogous to X-ray pictures in that differential absorption is imaged, phase ultrasonographs represent an entirely new source of information based on differential time of propagation. Thus, a new source of information is made available for detailed analysis.

Heyser, R. C.

Time-adjusted variable resistor

Timing mechanism was developed effecting extremely precisioned highly resistant fixed resistor. Switches shunt all or portion of resistor; effective resistance is varied over time interval by adjusting switch closure rate.

Heyser, R. C.

Pulse-width-modulated device for precision temperature control

Temperature controller is described which reduces difference between temperature oscillations about control point. Standard temperature-sensitive resistor element is utilized which is highly stable and reproducible. Temperature sensing circuitry is conventional dc bridge with power supplied by battery or highly regulated supply source.

Heyser, R. C.