Search NASA⌕ Search

Engineering topics

Higdon, N. S.

Publications and source records attributed to Higdon, N. S..

Tropospheric water vapor measurements with an airborne lidar system

A differential absorption lidar system has been developed for the remote measurement of atmospheric water vapor and aerosol distributions from an aircraft. The first extensive observations of H2O and aerosols in the lower troposphere made with this system are briefly discussed.

Browell, E. V.↗

Airborne lidar observations in the wintertime Arctic stratosphere - Polar stratospheric clouds

Polar stratospheric cloud (PSC) distributions in the wintertime Arctic stratosphere and their optical characteristics were measured with a multiwavelength airborne lidar system as part of the 1989 Airborne Arctic Stratospheric Expedition. PSCs were observed on 10 flights between January 6 and February 2, 1989, into the polar vortex. The PSCs were found in the 14-27 km altitude range in regions where the temperatures were less than 195 K. Two types of aerosols with different optical characteristics (Types 1a and 1b) were observed in PSCs thought to be composed of nitric acid trihydrate. Water ice PSCs (Type 2) were observed to have high scattering ratios (greater than 10) and high aerosol depolarizations (greater than 10 percent) at temperatures less than 190 K.

Browell, E. V.↗

Raman-shifted dye laser for water vapor DIAL measurements

For improved DIAL measurements of water vapor in the upper troposphere or lower stratosphere, narrowband (about 0.03/cm) laser radiation at 720- and 940-nm wavelengths was generated by stimulated Raman scattering (SRS), using the narrow linewidth (about 0.02/cm) output of a Nd:YAG-pumped dye laser. For a hydrogen pressure of 350 psi, the first Stokes conversion efficiencies to 940 nm were 20 percent and 35 percent, when using a conventional and waveguide Raman cell, respectively. The linewidth of the first Stokes line at high cell pressures, and the inferred collisional broadening coefficients, agree well with those previously measured in spontaneous Raman scattering.

Grossmann, B. E.↗

Linewidth characteristics of Raman-shifted dye laser output at 720 and 940 nm

Raman conversion efficiency and line broadening are reported for Stokes operation at 720 and 940 nm, with hydrogen and deuterium as the Raman source, and using an Nd:YAG pumped Quanta-Ray PDL-2 dye laser. The dye laser linewidth is 0.2/cm (FWHM) with the grating alone as an intracavity element, and the conversion efficiency at 400 psi was found to be 40 and 20 percent for outputs of 720 and 940 nm, respectively. Pressure broadening coefficients of (9.2 + or - 0.9) x 10 to the -5th per cm/psi for hydrogen, and 7.7 x 10 to the -5th per cm/psi for deuterium, were obtained in good agreement with previous results. The linewidth at the first Stokes wavelength was shown to be determined by pressure broadening in the Raman medium.

Grossmann, B. E.↗

Linewidth characteristics of Raman-shifted dye laser output at 720 and 940 nm

Existing DIAL systems for water vapor measurements in the troposphere operate at wavelengths near 720 nm. The use of stronger water vapor absorption lines in the range 930 to 960 nm will significantly improve DIAL measurements in the upper troposphere and lower stratosphere where water vapor concentrations are low. The generation of light at 940 nm using a frequency doubled Nd:YAG pumped dye laser is inefficient due to the small absorption if infrared dyes at the pump wavelength. However, 940 nm generation utilizing stimulated Raman scattering of dye lasers is attractive because of a potentially high conversion efficiency plus the possibility of retaining the narrow linewidth available from some dye lasers. The Raman conversion efficiency and line broadening are presented for first Stokes operation at 720 and 940 nm using hydrogen and deuterium as the Raman media.

Grossmann, B. E.↗

Linewidth characteristics of Raman-shifted dye laser output at 720 and 940 nm

A compact and simple simultaneous multi-wavelength dye laser cavity was developed for a differential absorption technique. Dielectric multilayer interference filters were inserted inside the cavities as tuning elements, and two types of a DIAL system were constucted by using the dye laser tuned with dielectric multilayer filters to measure NO2 concentration. The usefulness of this dye laser was clarified for the differential absoroption technique in outdoor experiments. Some basic designs of the laser cavity with these filters to get simultaneously multi-wavelength output are summarized.

Grossmann, B. E.↗

A blackbody-pumped CO2-N2 transfer laser

A compact blackbody-pumped CO2-N2 transfer laser was constructed and the significant operating parameters were investigated. Lasing was achieved at 10.6 microns by passing preheated N2 through a 1.5-mm-diameter nozzle to a laser cavity where the N2 was mixed with CO2 and He. An intrinsic efficiency of 0.7 percent was achieved for an oven temperature of 1473 K and N2 oven pressure of 440 torr. The optimum laser cavity consisted of a back mirror with maximum reflectivity and an output mirror with 97.5-percent reflectivity. The optimum gas mixture was 1CO2/.5He/6N2. The variation of laser output was measured as a function of oven temperature, nozzle diameter, N2 oven pressure, He and CO2 partial pressures, nozzle-to-oven separation, laser cell temperature, and output laser mirror reflectivity. With these parameters optimized, outputs approaching 1.4 watts were achieved.

Deyoung, R. J.↗