Search NASA⌕ Search

Engineering topics

Hill, Deborah

Publications and source records attributed to Hill, Deborah.

The Completion of Surrogate Testing for Low-Temperature TEX and a Look Towards the Future

To address the mounting need for below room temperature nuclear data validation, the Low-Temperature Thermal Epithermal eXperiments (LT-TEX) have been designed. Validation of low-temperature neutron cross sections is necessary to verify any operation at temperatures below room temperature which is typically observed in environments far from the equator. For example, a fissile material transportation truck may routinely observe ambient temperatures down to -40°C, which is the lower temperature bound of the normal conditions of transportation defined in the United States Title 10 Code of Federal Regulations §71.71c2. Additionally, sub-room temperature benchmarks can validate newly produced cross sections, that include novel thermal scattering laws, from North Carolina State University.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

TEX-HEU: Integral Experiment Execution with Polyethylene at Very Low Temperatures

The low-temperature variant of the TEX HEU (called Low-Temperature TEX or sometimes LT TEX) campaign is a highly anticipated and necessary experimental series by the greater nuclear science community. Fundamentally, the need for low-temperature integral experiments is required to perform validation of cross sections below room temperature. There has been substantial international interest in low-temperature benchmarks to validate below room temperature cross sections, namely talks given at the 2019 International Conference on Nuclear Criticality (ICNC): UK (Watson, 2019), France (Milin, 2019), and UK (Gan & Wilson, 2019). Additionally, NCSP funded thermal scattering laws (TSLs) were produced by North Carolina State University and require low-temperature benchmarks to validate them. Validation of low-temperature cross sections is also necessary for criticality safety applications. One particularly important application is to ensure that during transportation, fissile materials must remain subcritical under normal ambient conditions which is defined as temperatures down to -40°C/°F by the United States 10 CRF 71 as well as a regulation put forward by the International Atomic Energy Agency (IAEA).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

IER-479/547: Low-Temperature TEX Surrogate Testing and Reflector Design [Slides]

This lecture includes a look into progress in surrogate testing. This includes a new chiller that has been fabricated and testing that has resumed. Additional tests are being conducted, including: using formed aluminum gaskets, extended testing with natural uranium, testing with pseudo-spindle, testing with no vacuum. This lecture includes a look into the Reflector Design. Results for detailed model are consistent with results presented in CED-2. Calculations provide flexibility in the physical design of the reflectors (e.g. reflector segment widths and heights). Provided initial CAD models of reflector components.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IER-479/547: Low-Temperature TEX Final Design and Surrogate Measurements [Slides]

This presentation covers the final design, and measurements of the Low-Temperature TEX. Visual Diagrams of the apparatus and detailed part explanations are included. Neutronic calculations for Low-Temperature TEX was performed. Six configurations were proposed. Thermal analysis for the boundary cases was performed. Thermal testing with surrogate materials has been underway and testing will resume shortly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress Towards the Reality of Low-Temperature Critical Experiments with Low-Temperature TEX

Integral benchmarks for criticality safety do not exist below room temperature. Incredible support for below room temperature benchmarks is present across the international community. Validation of low-temperature neutron cross sections is necessary to verify any operation at temperatures below room temperature which is typically observed in environments far from the equator. For example, a fissile material transportation truck may routinely observe ambient temperatures down to -40°C, which is the lower temperature bound of the normal conditions of transportation defined in the United States Title 10 Code of Federal Regulations §71.71c2. Similarly, the IAEA, which contains 176 member states, has the same requirement for subcriticality for fissile material transportation. Additionally, sub-room temperature benchmarks can validate newly produced cross sections, that include novel thermal scattering laws, from North Carolina State University. A six-case experiment designed based off the TEX-HEU baseline experiments has been proposed utilizing a chilled vacuum chamber capable of cooling the HEU stack down to -50°C. The six proposed configurations span the entire neutron fission energy range and can be tested at intermediate temperatures between room temperature and -40°C. Of the six configurations, the fastest case utilizes nearly 135 kg of HEU. Understanding the system is required prior to critical experiment operations. In order to test the functionality of the system, testing with surrogate fuel materials has been conducted. The following discusses the design of the low temperature TEX (LT-TEX) experiment as well as the progress made via surrogate testing towards a reality in which low-temperature integral benchmarks exist in the International Criticality Safety Benchmark Evaluation Project (ICSBEP).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Towards an Era of Low-Temperature Integral Critical Experiments: Surrogate Testing of Low-Temperature TEX Configurations

United States and IAEA regulations for the transportation of radioactive materials require that fissile materials must be subcritical under expected ambient temperatures ranging from -40°C to 38°C. While historical experiments have been conducted at room and elevated temperatures, no criticality integral benchmarks exist for temperatures below room temperature. The Low-Temperature Thermal Epithermal eXperiments (LT-TEX) aim to provide benchmark evaluations down to -40°C. The LT-TEX design incorporates stacked HEU plates interspersed with varying thicknesses of polyethylene disks to provide varying levels of moderation, with five configurations at 20°C having already been benchmarked. A novel vacuum/cryogenic chamber was fabricated to contain the LT-TEX configurations in a thermally isolated environment and cool it to -40°C. Prior to testing with fissile materials, testing with surrogate fuel plates was performed to characterize the thermal properties of the system, ensure no condensation forms on the stack, and to test that the uranium plates would not warp, or fracture during the thermal cycling. Surrogate testing has characterized the cryogenic chamber and verified its viability to perform the benchmark experiments, allowing for the next steps in the LT-TEX experimental campaign. The results of the surrogate testing are discussed and compared to heat transfer calculations performed as part of the experiment design process, to establish confidence in the thermal behavior of the system.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

IER-479: Final Design of Low-Temperature TEX Experiments [Slides]

This presentation discusses the final design of low-temperature Thermal Epithermal eXperiments (TEX) experiments. Designed to validate low temperature cross sections and crit safety analyses. The presentation includes discussion on Low-Temp TEX Chamber a Cryostat Chamber capable of cooling between room temp and -40c. Finally, the presentation touches on reactivity via separation where the need to know how the system will behave approaching critical as lifted into annular reflector is analyzed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Integral Experiment Final Design for Thermal/Epithermal eXperiments (TEX) using Highly Enriched Uranium with Polyethylene at Low Temperature (IER-479 CED-2 Report)

The goal of IER-479 is to design uranium critical experiments that can be used to validate low temperature cross sections and criticality safety analyses over multiple neutron energy regimes. Currently, there are no benchmarks in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) handbook at temperatures lower than room temperature (International Criticality Safety Benchmark Evaluation Project Handbook, 2019). However, there are many needs for validation of criticality safety analysis at lower temperatures, including meeting transportation requirements and operations conducted outside or in unheated facilities. Additionally, NCSP has funded North Carolina State (NCSU) to generate new thermal scattering laws, including at lower temperatures, and the lack of integral benchmarks impedes data testing of these new cross sections. To address these needs, this report will present a critical experiment design covering various fission energy regimes with a goal temperature of -40°C (-40°F), which is based on the lower bound of expected non-cryogenic operational temperatures. The goal of the U.S. Nuclear Criticality Safety Program’s (NCSP) Thermal/Epithermal eXperiments (TEX) is to design and conduct new critical experiments to address high priority nuclear data needs from the nuclear criticality safety and nuclear data communities. The TEX program includes two series of baseline experimental configurations, one based on plutonium fuel (plutonium-aluminum Zero Power Physics Reactor (ZPPR) plates) and the other based on uranium fuel (highly enriched uranium (HEU) plates), that are moderated with varying thickness of polyethylene to create assemblies which span the thermal, intermediate, and fast fission energy regimes. The configurations are designed to be easily modified (for example, to add diluent materials of interest) to allow for efficient generation of additional benchmark configurations and allow for added nuclear data testing utility when comparing modified configurations to baseline configurations. The goal of IER-479 is to use the TEX-HEU concept (stack of HEU plates and polyethylene moderators) to design a critical experiment that can be used to validate low temperature cross sections and criticality safety analyses.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗