Engineering topics
Hitlin, D. G.
Publications and source records attributed to Hitlin, D. G..
Observation of the Decay D 0 → K − π + e + e −
Not Available
Search for a Stable Six-Quark State at BABAR
Not Available
Study of the reactions e + e − → π + π − π 0 π 0 π 0 and π + π − π 0 π 0 η at center-of-mass energies from threshold to 4.35 GeV using initial-state radiation
Not Available
Measurement of the γ * γ * → η ′ transition form factor
Not Available
Search for the decay mode B 0 → p p p ¯ p ¯
Not Available
Measurement of the spectral function for the τ − → K − K S ν τ decay
Not Available
Study of ϒ ( 1 S ) radiative decays to γ π + π − and γ K + K −
Not Available
Study of the process e + e − → π + π − η using initial state radiation
Not Available
The Mu2e undoped CsI crystal calorimeter
We present the Mu2e experiment at Fermilab will search for Charged Lepton Flavor Violating conversion of a muon to an electron in an atomic field. The Mu2e detector is composed of a tracker, an electromagnetic calorimeter and an external system, surrounding the solenoid, to veto cosmic rays. The calorimeter plays an important role to provide: a) excellent particle identification capabilities; b) a fast trigger filter; c) an easier tracker track reconstruction. Two disks, located downstream of the tracker, contain 674 pure CsI crystals each. Each crystal is read out by two arrays of UV-extended SiPMs. The choice of the crystals and SiPMs has been finalized after a thorough test campaign. A first small scale prototype consisting of 51 crystals and 102 SiPM arrays has been exposed to an electron beam at the BTF (Beam Test Facility) in Frascati. Lastly, although the readout electronics were not final, results show that the current design is able to meet the timing and energy resolution required by the Mu2e experiment.
The Mu2e Calorimeter Final Technical Design Report
Since the first version of the Mu2e TDR released at the beginning of 2015, the Mu2e Calorimeter system has undergone a long list of changes to arrive to its final design. These changes were primarily caused by two reasons: (i) the technology choice between the TDR proposed solution of BaF2 crystals readout with solar blind Avalanche Photodiodes (APDs) and the backup option of CsI crystals readout with Silicon Photomultipliers (SiPM) has been completed and (ii) the channels numbering, the mechanical system and the readout electronics were substantially modified while proceeding with engineering towards the final project. This document updates the description of the calorimeter system adding the most recent engineering drawings and tecnical progresses.
Quality Assurance on Undoped CsI Crystals for the Mu2e Experiment
The Mu2e experiment is constructing a calorimeter consisting of 1,348 undoped CsI crystals in two disks. Each crystal has a dimension of 34 x 34 x 200 mm 3 , and is readout by a large area silicon PMT array. A series of technical specifications was defined according to physics requirements. Preproduction CsI crystals were procured from three firms: Amcrys, Saint-Gobain and Shanghai Institute of Ceramics. We report the quality assurance on crystal's scintillation properties and their radiation hardness against ionization dose and neutrons. With a fast decay time of 30 ns and a light output of more than 100 p.e./MeV measured with a bi-alkali PMT, undoped CsI crystals provide a cost-effective solution for the Mu2e experiment.
Measurement of the e + e - → π + π - π 0 π 0 cross section using initial-state radiation at BABAR
Here, the process e + e – →π + π – 2π 0 γ is investigated by means of the initial-state radiation technique, where a photon is emitted from the incoming electron or positron. Using 454.3 fb –1 of data collected around a center-of-mass energy of √s=10.58 GeV by the BABAR experiment at SLAC, approximately 150000 signal events are obtained. The corresponding nonradiative cross section is measured with a relative uncertainty of 3.6% in the energy region around 1.5 GeV, surpassing all existing measurements in precision. Using this new result, the channel’s contribution to the leading order hadronic vacuum polarization contribution to the anomalous magnetic moment of the muon is calculated as (gπ + π – 2π 0 μ –2)/2=(17.9 ± 0.1 stat ± 0.6 syst )×10–10 in the energy range 0.85 GeV < E CM < 1.8 GeV. In the same energy range, the impact on the running of the fine-structure constant at the Z 0 -pole is determined as Δαπ + π – 2π 0 (M 2 Z )=(4.44 ± 0.02 stat ± 0.14 syst ) × 10 –4 . Furthermore, intermediate resonances are studied and especially the cross section of the process e + e – →ωπ 0 →π + π – 2π 0 is measured.
Measurement of the D * ( 2010 ) + - D + Mass Difference
Here, we measure the mass difference, Δm + , between the D* (2010) + and the D + using the decay chain D* (2010) + → D + π 0 with D + → K - π + π + . The data were recorded with the BABAR detector at center-of-mass energies at and near the Υ(4S) resonance, and correspond to an integrated luminosity of approximately 468 fb -1 . We measure Δm + = (140 601.0 ± 6.8 [stat] ± 12.9 [syst] ) keV . We combine this result with a previous BABAR measurement of Δm 0 ≡ m(D* (2010) + ) - m (D 0 ) to obtain Δm D = m (D + ) - m (D 0 ) = ( 4824.9 ± 6.8 [stat] ± 12.9 [syst]) keV . These results are compatible with and approximately five times more precise than the Particle Data Group averages.
Design, status and test of the Mu2e crystal calorimeter
The Mu2e experiment at Fermilab searches for the charged-lepton flavor violating neutrino-less conversion of a negative muon into an electron in the field of an aluminum nucleus. The dynamics of such a process is well modeled by a two-body decay, resulting in a monoenergetic electron with an energy slightly below the muon rest mass (104.967 MeV). The calorimeter of this experiment plays an important role to provide excellent particle identification capabilities and an online trigger filter while aiding the track reconstruction capabilities. The baseline calorimeter configuration consists of two disks each made with ~700 undoped CsI crystals read out by two large area UV-extended Silicon Photomultipliers. Furthermore, these crystals match the requirements for stability of response, high resolution and radiation hardness. In this paper we present the final calorimeter design.
Evidence for C P violation in B + → K * ( 892 ) + π 0 from a Dalitz plot analysis of B + → K S 0 π + π 0 decays
We report a Dalitz plot analysis of charmless hadronic decays of charged B mesons to the final state K 0 S π + π 0 using the full BABAR data set of 470.9 ± 2.8 million B¯B events collected at the Υ(4S) resonance. We measure the overall branching fraction and CP asymmetry to be B(B + → K 0 π + π 0 ) = (31.8 ± 1.8 ± 2.1 +6.0 –0.0 ) × 10 –6 and A CP (B + → K 0 π + π 0 ) = 0.07 ± 0.05 ± 0.03 +0.02 –0.03 , where the uncertainties are statistical, systematic, and due to the signal model, respectively. This is the first measurement of the branching fraction for B + → K 0 π + π 0 . We find first evidence of a CP asymmetry in B + → K*(892) + π 0 decays: A CP (B + → K*(892) + π 0 ) = –0.52 ± 0.14 ± 0.04 +0.04 –0.02 . The significance of this asymmetry, including systematic and model uncertainties, is 3.4 standard deviations. As a result, we also measure the branching fractions and CP asymmetries for three other intermediate decay modes.
Search for Invisible Decays of a Dark Photon Produced in e + e − Collisions at BaBar
Not Available
Measurement of the e + e - → K s 0 K ± π ∓ π 0 and K s 0 K ± π ∓ η cross sections using initial-state radiation
The processes e + e - → K$0\atop{S}$ K ± π ∓ π 0 and e + e - → K$0\atop{S}$ K ± π ∓ η are studied over a continuum of energies from threshold to 4 GeV with the initial-state photon radiation method. Using 454 fb -1 of data collected with the BABAR detector at the SLAC PEP-II storage ring, the first measurements of the cross sections for these processes are obtained. The intermediate resonance structures from K* 0 (Kπ) 0 , K *(892) ± (Kπ) ∓ , and K$0\atop{S}$K ± ρ ∓ are studied. Lastly, the J / ψ is observed in all of these channels, and corresponding branching fractions are measured.