Search NASASearch

Engineering topics

Hlanze, Philani

Publications and source records attributed to Hlanze, Philani.

Virtual refrigerant charge sensor for variable-speed heat pumps based on feature selection

The refrigerant charge level in heat pump systems significantly impacts their energy efficiency. Virtual refrigerant charge (VRC) sensing technology has been comprehensively investigated and well-established due to its lower cost compared to physical sensors. However, the previous VRC research often relied on expert judgment and physical reasoning for their variable selection, which can potentially select redundant (or highly correlated) or insignificant features, and it is also primarily focused on single-speed systems. To address these challenges, this study proposes a VRC algorithm for variable-speed heat pumps that selects features through a rigorous feature selection method in combination with physical insights. We also propose a piecewise linear model structure segmented by subcooling temperature to accurately predict charge levels, particularly when subcooling temperatures are substantially low. The proposed algorithm was evaluated using experimental data of a residential R410A heat pump, and the performance was compared with two baseline VRC algorithms. The results are: (1) The proposed algorithm outperforms for the case with subcooling temperature less than 1 °C. (2) The proposed algorithm achieves a tested mean absolute percentage error (MAPE) of 4.23%, and improves the overall accuracy for cooling conditions by approximately 60%, compared with the two baseline algorithms. (3) The proposed algorithm uses two fewer features and improves the accuracy for undercharge cooling conditions by 68.0%, compared with baseline algorithm 2. These improvements enhance prediction accuracy and prevent overfitting, providing a more reliable refrigerant charge level prediction and helping improve the heat pump energy efficiency.

Liang, Chenjiyu

Seasonal performance evaluation of zero-superheat active refrigerant charge control for variable-speed heat pumps

Heat pumps account for a significant portion of electricity consumption in buildings, making their energy efficiency a critical area of research. Control optimization is recognized as an effective approach for enhancing the efficiency of building HVAC systems. Specifically, since the efficiency of heat pumps increases with reduced superheat and the optimal refrigerant charge level varies with operating conditions, zero-superheat active charge control is a promising strategy to maximize the system’s COP. However, due to its complexity, this control strategy remains in the research phase and has only been tested under limited operating conditions. This paper proposes a methodology to evaluate the seasonal performance improvement of zero-superheat active charge control across a full range of heating conditions in buildings. The methodology includes the development of an optimal controller that utilizes an accumulator to store excess refrigerant and manages the active charge level at zero superheat through subcooling control, as well as the creation of a detailed physics-based heat pump model. Targeted a 3-ton variable-speed heat pump with R410A refrigerant, we selected ten U.S. cities representing different climate regions for seasonal performance evaluation. Our simulations indicate that, depending on the climate conditions, the optimal control strategy could achieve energy savings ranging from 5.8 % to 8.0 % over the entire heating season. These results suggest that zero-superheat active charge control, combined with coordinated compressor and fan speeds, could substantially improve the energy efficiency of heat pump systems while maintaining the required heating capacity.

Guo, Fangzhou