Search NASA⌕ Search

Engineering topics

Hoard, John W.

Publications and source records attributed to Hoard, John W..

Online Control of Process Variance Using Feedback

For many stochastic control problem formulations, design objectives typically include constraining the covariance of the outputs of the system. Recent engineering challenges have demonstrated an interest in controlling system output covariances to a setpoint. However, open-loop control of system output covariance can be exceptionally challenging when the system has significant plant uncertainties. This paper explores closed-loop control of the system’s output covariance using a windowed variance function. The stochastic nature of the windowed variance feedback means that root locus and other classical control design techniques cannot be immediately used. Expected value analysis is used to generate transfer functions for the average response of such systems, and the results are used to design controllers. Stochastic simulations are presented to verify the analytical results and make other observations concerning closed-loop variance control.

Bieniek, Mitchell↗

CFD Analysis Of Particle Transport In Axi-Symmetric Tubes Under The Influence Of Thermophoretic Force

In this study, we developed two frameworks to investigate the thermophoretic particulate deposition in non-isothermal tube flows conveying particles ranging from 10 to 300 nm; a one dimensional model where the variables are assumed to be uniform in each cross section perpendicular to the tube axis and an axi-symmetric model where the aforementioned assumption is relaxed. In the one dimensional model, the rate of mass deposition along the inner surface of the tube is computed based on the local thermophoretic velocity of the particulate phase at the wall. This velocity is proportional to the radial gradient of the temperature at the wall and is calculated via some empirical correlations for heat transfer in tube flows. In the axi-symmetric model, the rate of deposition is computed through the Fick s law after solving the species transport equation for the solid phase. We included the formation of the soot layer through moving the gas solid interface in both models. The tube effectiveness (the ratio of actual heat transfer to the maximum possible heat transfer) decreases due to the formation of the layer. Model outputs including deposited mass along the tube wall and the tube effectiveness drop have been compared against experiments. While the computed results through both models agree with the trend of experimental data, the axi-symmetric results are closer to the experiments in most cases. The calculated deposited mass is smaller (and closer to experiments) for the axi-symmetric model compared to the one dimensional model in all cases. This indicates that the axi-symmetric model estimates the deposited mass more accurately.

Abarham, Mehdi↗

Numerical Modeling and Experimental Investigations of EGR Cooler Fouling in a Diesel Engine

EGR coolers are mainly used on diesel engines to reduce intake charge temperature and thus reduce emissions of NOx and PM. Soot and hydrocarbon deposition in the EGR cooler reduces heat transfer efficiency of the cooler and increases emissions and pressure drop across the cooler. They may also be acidic and corrosive. Fouling has been always treated as an approximate factor in heat exchanger designs and it has not been modeled in detail. The aim of this paper is to look into fouling formation in an EGR cooler of a diesel engine. A 1-D model is developed to predict and calculate EGR cooler fouling amount and distribution across a concentric tube heat exchanger with a constant wall temperature. The model is compared to an experiment that is designed for correlation of the model. Effectiveness, mass deposition, and pressure drop are the parameters that have been compared. The results of the model are in a good agreement with the experimental data.

33 ADVANCED PROPULSION SYSTEMS↗

MODELING OF THERMOPHORETIC SOOT DEPOSITION ANDHYDROCARBON CONDENSATION IN EGR COOLERS

EGR coolers are effective to reduce NOx emissions from diesel engines due to lower intake charge temperature. EGR cooler fouling reduces heat transfer capacity of the cooler significantly and increases pressure drop across the cooler. Engine coolant provided at 40-90 C is used to cool EGR coolers. The presence of a cold surface in the cooler causes particulate soot deposition and hydrocarbon condensation. The experimental data also indicates that the fouling is mainly caused by soot and hydrocarbons. In this study, a 1-D model is extended to simulate particulate soot and hydrocarbon deposition on a concentric tube EGR cooler with a constant wall temperature. The soot deposition caused by thermophoresis phenomena is taken into account the model. Condensation of a wide range of hydrocarbon molecules are also modeled but the results show condensation of only heavy molecules at coolant temperature. Thermal properties of fouled layer are calculated based on mass fraction of deposited soot and hydrocarbons. The experiments with the same conditions ran to validate the model. Hot EGR gases flow through the inner pipe and the coolant circulates around it in the outer pipe to keep a constant wall temperature. Effectiveness, deposited soot mass, condensed hydrocarbon mass, and pressure drop across the cooler are the parameters that have been compared. The results of the model are in a reasonably good agreement with the experimental results although there are some fields that need to be studied in future to improve the model.

33 ADVANCED PROPULSION SYSTEMS↗