Search NASA⌕ Search

Engineering topics

Hobbs, Kirby P.

Publications and source records attributed to Hobbs, Kirby P..

The impact of gas purity on observed reactivity with NO using inductively coupled plasma tandem mass spectrometry

Interference removal in inductively coupled plasma tandem mass spectrometry (ICP-MS/MS) is strongly dependent on the gas selected for use within the collision/reaction cell. There has been little investigation on the effects that reaction gas impurities may have on the resulting spectra. The reactivity of 60 elements was evaluated using nitric oxide (NO 99.5%) with and without a gas purifier to reduce H 2 O impurities to <100 pptV. Experiments were performed using V, Ce, Tl and Th to investigate the effects of purified NO at various flowrates (0.22–1.49 mL min -1 ). Purified NO was shown to significantly mitigate oxy-hydride interferences, improve total ion sensitivity (notable at high gas flows), and shift product distributions advantageously. The reduction in oxy-hydride species results in a product distribution favoring the major expected products, where signals were shown to increase by an order of magnitude. Reduced background and increased signal for the major expected products provides avenues for improving various analytical applications of ICP-MS/MS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Separation of gold from irradiated actinide material utilizing a 2- thenoyltrifluoroacetone extraction resin

Post-detonation nuclear forensics capabilities depend on the ability to rapidly isolate radionuclides to improve measurement quality. In this work an extraction chromatography resin was developed utilizing the extractants thenoyltrifluoroacetone and 1-octanol supported on Eichrom prefilter resin. Here the resin was tested in nitric and hydrochloric acid matrices. In nitric acid matrices the resin is able to extract zirconium, while in hydrochloric acid matrices it is possible to extract iron and gallium. In all acid conditions tested gold is retained but can be removed from the column with a 10% thiourea rinse.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Assessing Gas-Phase Ion Reactivity of 50 Elements with NO and the Direct Application for 239 Pu in Complex Matrices Using ICP-MS/MS

Understanding the reactivity of metal cations with various reaction gases in ICP-MS/MS is important to determine the best gas to use for a given analyte/interference pair. In this study, nitric oxide (NO) was investigated as the reaction gas following previous experimental designs. The reactions with 50 elements were investigated to examine periodic trends in reactivity, validate theoretical modeling of reaction enthalpies as a method to screen reactant gases, and provide a baseline for potential in-line gas separation methods. ICP-MS/MS studies involving actinides are typically limited to Th, U and Pu, with analyses of Np and Am rarely reported in the literature. To date, only two previous methods have investigated the use of NO in ICP-MS/MS analyses. To showcase the utility of NO, a method was developed to measure 239 Pu in the presence of environmental matrix constituent and other actinides, like what could be expected from post-detonation debris, with no chemical separation prior to analysis. 239 Pu + was reacted to form 239 Pu 16 O + , eliminating interferences derived from the sample matrix by measuring 239 Pu + intensity at m/z = 255 ( 239 Pu 16 O + ). To validate NO for 238 U 1 H + interference removal in environmental matrices, standard reference materials were diluted to 1 mg per gram of solution and spiked to 0.05 pg/g of 239 Pu and 1 µg/g 238 U (Pu/U = 5 x 10 -8 ). Measured 239 Pu concentrations were within 6% of the spiked value. In conclusion, these results demonstrate that reliable 239 Pu measurements can be made at levels relevant to nuclear forensics without the need for extensive chemical matrix separation prior to analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The importance of ion kinetic energy for interference removal in ICP-MS/MS

Here, the effect of ion kinetic energy on gas phase ion reactivity with ICP-MS/MS was investigated in order to explore tuning strategies for interference removal. The collision/reaction gases CO 2 , N 2 O and O 2 were used to observe the ion product distribution for 48 elements using an Agilent tandem ICP-MS (ICP-MS/MS) as a function of reaction gas flow rate (pressure) and ion kinetic energy. The kinetic energy of the incident ion was varied by adjusting the octopole bias (V oct ). The three gases all form oxides (MO + ) as the primary product with differing reaction enthalpies that result in distinct differences in the ion energies required for reaction with product ion distributions that vary with Voct. Consequently, by varying the ion kinetic energy (i.e., V oct ), differences in interference reactivity can be used to achieve maximum separation. Three practical application examples were reported to demonstrate how the ion kinetic energy can be varied to achieve the ideal ion product distribution for interference resolution: CO 2 for the removal of 238 U in Pu analyses, CO 2 for the removal of 40 Ar 16 O vs. 56 Fe, and O 2 for the removal of Sm in Eu analyses, analogous to Pu/Am. The results demonstrate how the starting ion energy defined by V oct is an important factor to fully leverage the utility of any given reaction gas to remove interferences in the mass spectrum using ICP-MS/MS.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Control of iodine and tellurium for use in domestic molybdenum-99 production efforts

Three initial proof-of-concept experiments were performed to test the removal of I and Te from solutions containing Mo for potential abatement during chemical processing to purify 99 Mo. All three proof-of-concept experiments produced results indicating that further optimization could provide methods for I and/or Te abatement from multiple matrices. Decamp and Happel (2013) describe the use of CL resin from Eichrom Technologies loaded with Ag + combined with Amberlite XAD-4 in the chromatographic separation of irradiated fission products in 1 M HNO 3 to separate iodine species where iodide and iodate react with Ag + and I2 adheres to the Amberlite resin. The method worked well under processing conditions in a medical isotope facility although many separation methods use higher concentrations of HNO 3 which could adversely impact the Ag + loading. The experiment performed here used a roughly 2 mL column of CL resin loaded with Ag + and Amberlite XAD-4 to separate µg quantities of I, Te, and Mo in 3 M HNO 3 .

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Erratum: Production and validation of scintillating structural components from low-background Poly(ethylene naphthalate)

Regretfully, the author list of the original paper did not contain the members of the groups being responsible for the HPGe screening, Radon emanation measurement and ICPMS surface characterization works. As the work performed is to be considered more than “just service work”, the authors together with the members of these groups have decided to amend the authors list. At publication the following authors were not included in the author list: • From Pacific Northwest National Laboratory, Richland, WA, U.S.A.: E.W. Hoppe, I.J. Arnquist, K.P. Hobbs, A.D. French, M.L. diVacri • From INFN, Laboratori Nazionali del Gran Sasso, 67100 Assergi, Italy: M. Laubenstein • From M. Smoluchowski Institute of Physics, Jagiellonian University, 30-348 Krakow, Poland: G. Zuzel The metadata of the present erratum are already correct.

99 GENERAL AND MISCELLANEOUS↗