Search NASA⌕ Search

Engineering topics

Hoffman, W. F.

Publications and source records attributed to Hoffman, W. F..

Nulling Data Reduction and On-Sky Performance of the Large Binocular Telescope Interferometer

The Large Binocular Telescope Interferometer (LBTI) is a versatile instrument designed for high angular resolution and high-contrast infrared imaging (1.5-13 micrometers). In this paper, we focus on the mid-infrared (8-13 micrometers) nulling mode and present its theory of operation, data reduction, and on-sky performance as of the end of the commissioning phase in 2015 March. With an interferometric baseline of 14.4 m, the LBTI nuller is specifically tuned to resolve the habitable zone of nearby main-sequence stars, where warm exozodiacal dust emission peaks. Measuring the exozodi luminosity function of nearby main-sequence stars is a key milestone to prepare for future exo-Earth direct imaging instruments. Thanks to recent progress in wavefront control and phase stabilization, as well as in data reduction techniques, the LBTI demonstrated in 2015 February a calibrated null accuracy of 0.05% over a 3 hr long observing sequence on the bright nearby A3V star Beta Leo. This is equivalent to an exozodiacal disk density of 15-30 zodi for a Sun-like star located at 10 pc, depending on the adopted disk model. This result sets a new record for high-contrast mid-infrared interferometric imaging and opens a new window on the study of planetary systems.

circumstellar matter aEuro" techniques: interferom↗

Thermal stability of lightweight graphite glass sandwich reflectors for far infrared astronomy

Graphite fiber-reinforced glass matrix composites are being developed for a variety of structural applications requiring excellent thermomechanical stability. These materials are ideally suited for lightweight, high strength, thermally stable infrared mirrors because of their low density, low thermal expansion, high strength and stiffness, and their ability to be machined, replicated and figured using standard polishing techniques. These properties are particularly promising for applications such as a 3-meter balloon-borne far-infrared and submillimeter telescope mirror which must be both very lightweight and able to retain its figure accuracy when cycled between room temperature and its operating temperature of -50 C. This paper presents the results of a set of low temperature optical tests conducted to determine the figure stability of a 30-cm diameter, frit-bonded graphite/glass mirror in the +20 to -60 C temperature range using a 10.6 micron laser interferometer. The results indicate that the residual change in figure was less than 0.3 microns, rms.

Bluege, J. H.↗