Laser measurement of the spectral extinction coefficients of fluorescent, highly absorbing liquids

A conceptual method is developed to deduce rapidly the spectral extinction coefficient of fluorescent, highly absorbing liquids, such as crude or refined petroleum oils. The technique offers the advantage of only requiring one laser wavelength and a single experimental assembly and execution for any specific fluorescent liquid. The liquid is inserted into an extremely thin wedge-shaped cavity for stimulation by a laser from one side and flurescence measurement on the other side by a monochromator system. For each arbitrarily selected extinction wavelength, the wedge is driven slowly to increasing thicknesses until the fluorescence extinguishes. The fluorescence as a function of wedge thickness permits a determination of the extinction coefficient using an included theoretical model. When the monochromator is set to the laser emission wavelength, the extinction coefficient is determined using the usual on-wavelength signal extinction procedure.

Hoge, F. E.↗

Application of the NASA airborne oceanographic lidar to the mapping of chlorophyll and other organic pigments

Laser fluorosensing techniques used for the airborne measurement of chlorophyll a and other naturally occurring waterborne pigments are reviewed. Previous experiments demonstrating the utility of the airborne oceanographic lidar (AOL) for assessment of various marine parameters are briefly discussed. The configuration of the AOL during the NOAA/NASA Superflux experiments is described. The participation of the AOL in these experiments is presented and the preliminary results are discussed. The importance of multispectral receiving capability in a laser fluorosensing system for providing reproducible measurements over wide areas having spatial variations in water column transmittance properties is addressed. This capability minimizes the number of truthing points required and is usable even in shallow estuarine areas where resuspension of bottom sediment is common. Finally, problems encountered on the Superflux missions and the resulting limitations on the AOL data sets are addressed and feasible solutions to these problems are provided.

Hoge, F. E.↗

Airborne simultaneous spectroscopic detection of laser-induced water Raman backscatter and fluorescence from chlorophyll a and other naturally occurring pigments

The airborne laser-induced spectral emission bands obtained simultaneously from water Raman backscatter and the fluorescence of chlorophyll and other naturally occurring waterborne pigments are reported here for the first time. The importance of this type data lies not only in its single-shot multispectral character but also in the application of the Raman line for correction or calibration of the spatial variation of the laser penetration depth without the need for in situ water attenuation measurements. The entire laser-induced fluorescence and Raman scatter emissions resulting from each separate 532-nm 10-nsec laser pulse are collected and spectrally dispersed in a diffraction grating spectrometer having forty photomultiplier tube detectors. Results from field experiments conducted in the North Sea and the Chesapeake Bay/Potomac River are presented. Difficulties involving the multispectral resolution of the induced emissions are addressed, and feasible solutions are suggested together with new instrument configurations and future research directions.

Hoge, F. E.↗

Absolute tracer dye concentration using airborne laser-induced water Raman backscatter

The use of simultaneous airborne-laser-induced dye fluorescence and water Raman backscatter to measure the absolute concentration of an ocean-dispersed tracer dye is discussed. Theoretical considerations of the calculation of dye concentration by the numerical comparison of airborne laser-induced fluorescence spectra with laboratory spectra for known dye concentrations using the 3400/cm OH-stretch water Raman scatter as a calibration signal are presented which show that minimum errors are obtained and no data concerning water mass transmission properties are required when the laser wavelength is chosen to yield a Raman signal near the dye emission band. Results of field experiments conducted with an airborne conical scan lidar over a site in New York Bight into which rhodamine dye had been injected in a study of oil spill dispersion are then indicated which resulted in a contour map of dye concentrations, with a minimum detectable dye concentration of approximately 2 ppb by weight.

Hoge, F. E.↗

The current status of airborne laser fluorosensing

Airborne laser fluorosensors have been used to identify and quantify specific substances in the aquatic environment. It has been shown that the sensor can identify and classify oil films. If the extinction coefficient is known then the thickness of thinner films (less than 20 micrometers) may be calculated. The intensity of the water Raman signal is proportional to the water volume sampled by the sensor and hence an effective attenuation coefficient for the water can be calculated. The same Raman measurement provides the normalization necessary to map chlorophyll and dye concentrations using the intensity of their respective fluorescence signatures.

Oneil, R. A.↗

Oil film thickness measurement using airborne laser-induced water Raman backscatter

The use of laser-induced water Raman backscatter for remote thin oil film detection and thickness measurement is reported here for the first time. A 337.1-nm nitrogen laser was used to excite the 3400-cm-1 OH stretch band of natural ocean water beneath the oil slick from an altitude of 150 m. The signal strength of the 381-nm water Raman backscatter was always observed to depress when the oil was encountered and then return to its original undepressed value after complete aircraft traversal of the floating slick. After removal of background and oil fluorescence contributions, the ratio of the depressed-to-undepressed airborne water Raman signal intensities, together with laboratory measured oil extinction coefficients, is used to calculate the oil film thickness.

Hoge, F. E.↗

Laser measurement of extinction coefficients of highly absorbing liquids

A coaxial dual-channel laser system has been developed for the measurement of extinction coefficients of highly absorbing liquids. An empty wedge-shaped sample cell is first translated laterally through a He-Ne laser beam to measure the differential thickness using interference fringes in reflection. The wedge cell is carefully filled with the oil sample and translated through the coaxially positioned dye laser beam for the differential attenuation or extinction measurement. Optional use of the instrumentation as a single-channel extinction measurement system and also as a refractometer is detailed. The system and calibration techniques were applied to the measurement of two crude oils whose extinction values were required to complete the analysis of airborne laser data gathered over four controlled spills.

Hoge, F. E.↗

Water depth measurement using an airborne pulsed neon laser system

The paper presents the water depth measurement using an airborne pulsed neon laser system. The results of initial base-line field test results of NASA airborne oceanographic lidar in the bathymetry mode are given, with water-truth measurements of depth and beam attenuation coefficients by boat taken at the same time as overflights to aid in determining the system's operational performance. The nadir-angle tests and field-of-view data are presented; this laser bathymetry system is an improvement over prior models in that (1) the surface-to-bottom pulse waveform is digitally recorded on magnetic tape, and (2) wide-swath mapping data may be routinely acquired using a 30 deg full-angle conical scanner.

Hoge, F. E.↗

Remote sensing of subsurface water temperature by laser Raman spectroscopy

This paper describes experimental remote sensing of subsurface water temperature using the Raman spectroscopic technique. By the use of a pulsed laser and range gating detection techniques, Raman scattering is analyzed as a function of depth in a radar-like echo mode, and thus subsurface profiles of temperature and transmission are obtained. Experiments are described in which Raman data using polarization spectroscopy has been obtained from a ship as a function of depth in ocean water near Grand Bahama Island. A spectral temperature accuracy of + or - 1 C has been obtained from this data in the first two optical attenuation lengths. Raman data obtained from ocean water using the NASA airborne oceanographic lidar is also presented.

Leonard, D. A.↗

Remote sensing of subsurface water temperature by Raman scattering

The application of Raman scattering to remote sensing of subsurface water temperature and salinity is considered, and both theoretical and experimental aspects of the technique are discussed. Recent experimental field measurements obtained in coastal waters and on a trans-Atlantic/Mediterranean research cruise are correlated with theoretical expectations. It is concluded that the Raman technique for remote sensing of subsurface water temperature has been brought from theoretical and laboratory stages to the point where practical utilization can now be developed.

Leonard, D. A.↗

Experimental remote sensing of subsurface temperature in natural ocean water

The first successful depth-resolved remote sensing measurements of subsurface ocean water temperature were obtained by spectral analysis of the 3400 per cm O-H stretching Raman band of liquid water. Raman spectral data were obtained from a research vessel at various depths from the surface to 10 meters below the surface in a tidal estuary. The temperature inferred from the spectra was consistent with ground truth temperature to within the shot noise limited accuracy of plus or minus 2 C. The performance of a future fully developed airborne laser Raman water temperature measurement system is estimated on the basis of these first tests.

Leonard, D. A.↗

Integrated laser/radar satellite ranging and tracking system

A laser satellite ranging system that is mounted upon and integrated with a microwave tracking radar is reported. The 1-pulse/sec ruby laser transmitter is attached directly to the radar's elevation axis and radiates through a new opening in the radar's parabolic dish. The laser photomultiplier tube receiver utilizes the radar's existing 20-cm diam f/11 boresight telescope and observes through a similar symmetrically located opening in the dish. The laser system possesses separate ranging system electronics but shares the radar's timing, computer, and data handling/recording systems. The basic concept of the laser/radar is outlined together with a listing of the numerous advantages over present singular laser range-finding systems. The developmental laser hardware is described along with preliminary range-finding results and expectations.

Hoge, F. E.↗

Expected Seasat-A scientific results

The higher accuracy and extended coverage of the SEASAT-A altimeter allows for the determinations of a highly refined geoid, of open ocean currents and circulations, of ocean subsurface topography, and of earth surface topography. The radar altimeter on SEASAT-A is also considered as a tracking station in orbit for range and range rate tracking work.

Hoge, F. E.↗

A slope reversal video processor having amplitude and pulse width discrimination.

A timing discriminator whose output is relatively insensitive to input pulse width and amplitude is described. The video-handling technique is known as slope reversal processing and is based on tapped delay line estimation methods. The concept, design, breadboard construction, and preliminary laboratory test results are reviewed. The processor system features (1) a peak input voltage dynamic range of 80x starting at 100 microvolts; (2) a four stage preamplifier/line-driver having a voltage gain of 2400x; (3) a tapped delay-line estimator implemented for slope reversal triggering by differential comparison; (4) a nominal plus or minus 2.5 nsec shift of the output trigger leading edge over the entire input voltage range, (5) up to 7 dB discrimination against pulse widths less than 35 nsec; and (6) up to one order of magnitude reduction in the false alarm rate compared to a constant fraction system.

Hoge, F. E.↗