Search NASA⌕ Search

Engineering topics

Hok, Saphon

Publications and source records attributed to Hok, Saphon.

Assessment of two benzylation strategies for the analysis of nerve-agent derived ethyl- and pinacolyl methyl phosphonic acids in sandy loam soil by GC–MS

Despite their prohibition by the Chemical Weapons Convention, nerve agents (NAs) remain in use against military and civilian targets. Due to their high reactivity, NAs readily degrade to phosphonic acids, making them important markers in the inspection of areas of presumed NA use. In this work, we assess the use of benzylation to modify ethyl- and pinacolyl methylphosphonic acids, degradation products of VX and Soman respectively, for their efficient detection in a soil matrix at ~10 and ~1 μg/g using GC–MS. The soil matrix, Sandy Loam (SL), was chosen for its ubiquitous nature, complex composition with silica particles embedded in clay, and low organic content. In this study, we demonstrate that benzylation via benzyl bromide yields a LOD = 25.6 ng/mL for benzylated-EMPA and LOD = 30.1 ng/mL for benzylated-PMPA. This is superior to the use of p-methoxybenzyl trichloroacetimidate in providing stable phosphonic acid ester derivatives for analysis. A base-modified procedure for p-methoxybenzylation was explored in this study yielding a LOD = 29.1 ng/mL for p-methoxybenzylated-EMPA and LOD = 39.8 ng/mL for p-methoxybenzylated-PMPA. Both benzylation pathways (benzyl bromide and p-methoxybenzyl trichloroacetimidate) can be used to yield phosphonic acid derivatives that provide further confirmation of these Soman and VX degradation products in soil samples in investigative scenarios. The work herein represents the first application of benzylation methods for the analysis of these NA markers in the acidic, silicon-based SL soil.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determination of Synthetic Opioids Belonging to the Fentanyl Class in Silt Using Electron Ionization Gas Chromatography-Mass Spectrometry (GC-MS).

An extraction protocol from silt sediment of fentanyl and three analogs: acetylfentanyl, thiofentanyl and acetylthiofentanyl, spiked at two concentrations each and separately (at ~1 and ~10 µg/g), is described. In addition, the identity of the fentanyls preliminarily identified by electron ionization gas chromatography-mass spectrometry (EI-GC-MS) analysis, can be corroborated by reacting each opioid in the silt’s extract with 2,2,2-trichloroethoxycarbonyl chloride (Troc-Cl). Further, reaction between Troc-Cl and each opioid generates two unique products that can be used to retrospectively identify the original opioid therefore serving as a corroborating tool for known opioids as well as new, unknown fentanyl analogs.

60 APPLIED LIFE SCIENCES↗

Evaluation of Subetadex-α-methyl, a Polyanionic Cyclodextrin Scaffold, as a Medical Countermeasure against Fentanyl and Related Opioids

Subetadex-α-methyl (SBX-Me), a modified, polyanionic cyclodextrin scaffold, has been evaluated for its utilization as a medical countermeasure (MCM) to neutralize the effects of fentanyl and related opioids. Initial in vitro toxicity assays demonstrate that SBX-Me has a nontoxic profile, comparable to the FDA-approved cyclodextrin-based drug Sugammadex. Pharmacokinetic analysis showed rapid clearance of SBX-Me with an elimination half-life of ~7.4 h and little accumulation in major organs. SBX-Me was also evaluated for its ability to counteract the effects of fentanyl, carfentanil, and remifentanil in rats. Recovery times in rats exposed to sublethal fentanyl doses were found to be shorter when treated with SBX-Me after opioid exposure. The recovery times were reduced from ~35 to ~17 min for fentanyl, ~172 to ~59 min for carfentanil, and ~18 to ~12 min for remifentanil. SBX-Me increased the elimination half-life for fentanyl and remifentanil from 5.37 to 6.42 h and 8.24 to 9.74 h, respectively. These data support SBX-Me as a solid platform from which further research can be launched for the development of a MCM against the effects of fentanyl and its analogs. Furthermore, the data suggests that SBX-Me and other analogs are attractive candidates as broad spectrum opioids targeting MCMs.

Chemistry↗

Use of carbonyldiimidazole as a derivatization agent for the detection of pinacolyl alcohol, a forensic marker for Soman, by EI-GC–MS and LC-HRMS in official OPCW proficiency test matrices

Pinacolyl alcohol (PA), a key forensic marker for the nerve agent Soman (GD), is a particularly difficult analyte to detect by various analytical methods. In this work, we have explored the reaction between PA and 1,1'-carbonyldiimidazole (CDI) to yield pinacolyl 1H-imidazole-1-carboxylate (PIC), a product that can be conveniently detected by gas chromatography–mass spectrometry (GC–MS) and liquid chromatography-high-resolution mass spectrometry (LC-HRMS). Regarding its GC–MS profile, this new carbamate derivative of PA possesses favorable chromatographic features such as a sharp peak and a longer retention time (RT = 16.62 min) relative to PA (broad peak and short retention time, RT = 4.1 min). Additionally, the derivative can also be detected by LC-HRMS, providing an avenue for the analysis of this chemical using this technique where PA is virtually undetectable unless present in large concentrations. From a forensic science standpoint, detection of this low molecular weight alcohol signals the past or latent presence of the nerve agent Soman (GD) in a given matrix (i.e., environmental or biological). The efficiency of the protocol was tested separately in the analysis and detection of PA by EI-GC–MS and LC-HRMS when present at a 10 μg/mL in a soil matrix featured in the 44th PT and in a glycerol-rich liquid matrix featured in the 48th Official Organization for the Prohibition of Chemical Weapons (OPCW) Proficiency Test when present at a 5 μg/mL concentration. In both scenarios, PA was successfully transformed into PIC, establishing the protocol as an additional tool for the analysis of this unnatural and unique nerve agent marker by GC–MS and LC-HRMS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Practical benzylation of N,N -substituted ethanolamines related to chemical warfare agents for analysis and detection by Electron Ionization Gas Chromatography-Mass Spectrometry

The benzylation of three, low-molecular weight N,N-disubstituted ethanolamines related to chemical warfare agents (CWAs) to furnish derivatives with improved Gas Chromatography-Mass Spectrometry (GC-MS) profiles is described. Due to their low molecular weight and polar nature, N,N-disubstituted ethanolamines are notoriously difficult to detect by routine GC-MS analyses during Organisation for the Prohibition of Chemical Weapons (OPCW) proficiency tests (PTs), particularly in scenarios when they are present at low levels (~1-10 ppm) amidst more abundant interferences. Our studies revealed that the optimal derivatization conditions involved the treatment of the ethanolamine with benzyl bromide in the presence of an inorganic base (e.g., Na 2 CO 3 ) in dichloromethane at 55 °C for 2 hours. This optimized set of conditions were then successfully applied to the derivatization of N,N-dimethylethanolamine, N,N-diethylethanolamine and N,N-diisopropylethanolamine present separately at 1 and 10 μg/mL concentrations in a glycerol-rich matrix sample featured in the 48 th OPCW PT. The benzylated derivatives of the three ethanolamines possessed retention times long enough to clear the massive glycerol-containing matrix interferences. In conclusion, the protocol herein is introduced as an alternative method for derivatization of these CWA and pharmaceutically important species and should find broad applicability in laboratories where their routine forensic analysis is carried out.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Compound Specific Stable Isotope Signatures of Chemical Threat Agents: Incapacitants

In year 2 of this project (2017), our group focused on determining the causes of isotopic signatures in fentanyl. In order to better predict isotopic signatures in fentanyl, we analyzed the nitrogen isotope compositions of two key intermediates of fentanyl, NPP and ANPP. In addition, we analyzed additional fentanyl products produced using the Valdez route, along with five other alternative fentanyl routes. A new, more sensitive GC-C-IRMS method has been developed, which allows for compound specific isotope analysis of Chemical Attribution Signatures (CAS) in fentanyl.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Unsaturated Sulfur Crown Ethers Can Extract Mercury(II) and Show Promise for Future Copernicium(II) Studies: A Combined Experimental and Computational Study

The unsaturated hexathia-18-crown-6 (UHT18C6) molecule was investigated for the extraction of Hg(II) in HCl and HNO3 media. This extractant can be directly compared to the recently studied saturated hexathia-18-crown-6 (HT18C6). The default conformation of the S lone pairs in UHT18C6 is endodentate, where the pocket of the charge density, according to the crystal structures, is oriented toward the center of the ring, which should allow better extraction for Hg(II) compared to the exodentate HT18C6. Batch study experiments showed that Hg(II) had better extraction at low acid molarity (ca. 99% in HCl and ca. 95% in HNO 3 ), while almost no extraction was observed above 0.4 M HCl and 4 M HNO 3 (<5%). Speciation studies were conducted with the goal of delineating a plausible extraction mechanism. Density functional theory calculations including relativistic effects were carried out on both Hg(II)-encapsulated HT18C6 and UHT18C6 complexes to shed light on the binding strength and the nature of bonding. Our calculations offer insights into the extraction mechanism. In addition to Hg(II), calculations were performed on the hypothetical divalent Cn(II) ion, and showed that HT18C6 and UHT18C6 could extract Cn(II). Finally, the extraction kinetics were explored to assess whether this crown can extract the short-lived Cn(II) species in a future online experiment.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Compounds for central reactivation of organophosphorus-based compound-inhibited acetylcholinesterase and/or inactivation of organophosphorus-based acetylcholinesterase inhibitors and related compositions methods and systems for making and using them

Described herein are oxime compounds capable of inactivating OP-based AChE inhibitors, crossing the blood brain barrier (BBB), and/or reactivation of OP-inhibited acetylcholinesterase (AChE) and related methods, systems and compositions for inactivation of one or more OP-based AChE inhibitors, therapeutic and/or prophylactic treatment of an individual, and/or decomposition of OP-based AChE inhibitors for decontamination.

Valdez, Carlos A.↗

Development of a CNS-permeable reactivator for nerve agent exposure: an iterative, multi-disciplinary approach

Nerve agents have experienced a resurgence in recent times with their use against civilian targets during the attacks in Syria (2012), the poisoning of Sergei and Yulia Skripal in the United Kingdom (2018) and Alexei Navalny in Russia (2020), strongly renewing the importance of antidote development against these lethal substances. The current standard treatment against their effects relies on the use of small molecule-based oximes that can efficiently restore acetylcholinesterase (AChE) activity. Despite their efficacy in reactivating AChE, the action of drugs like 2-pralidoxime (2-PAM) is primarily limited to the peripheral nervous system (PNS) and, thus, provides no significant protection to the central nervous system (CNS). This lack of action in the CNS stems from their ionic nature that, on one end makes them very powerful reactivators and on the other renders them ineffective at crossing the Blood Brain Barrier (BBB) to reach the CNS. In this report, we describe the use of an iterative approach composed of parallel chemical and in silico syntheses, computational modeling, and a battery of detailed in vitro and in vivo assays that resulted in the identification of a promising, novel CNS-permeable oxime reactivator. Additional experiments to determine acute and chronic toxicity are ongoing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Acylation as a successful derivatization strategy for the analysis of pinacolyl alcohol in a glycerol-rich matrix by GC-MS: application during an OPCW Proficiency Test

A derivatization protocol based on the acylation of pinacolyl alcohol (PA), an important marker for the nerve agent soman, is presented. The procedure provides a convenient means of detecting, by gas chromatography-mass spectrometry (GC-MS), PA when present at a low concentration in a complex glycerol/alcohol-rich matrix. While there are only two reports describing the specific analysis of PA in matrices at low concentrations, the protocol described herein represents the first of its kind in the analysis of PA in a highly reactive matrix. Two alternative paths for the protocol’s execution are presented. The first involves the direct derivatization of the PA with either acetyl or benzoyl chloride; both reactions yield ester products with significantly different retention times than those of the interferences of the reactive glycerol-rich matrix and in areas of the GC-chromatogram featuring lower levels of matrix interferences. A second procedure involved an initial diethyl ether/aqueous extraction of the matrix; while the extraction was found to substantially remove many of the hydrophilic matrix components and improve the overall derivatization, it also led to some loss of PA available for the derivatization. Both protocols were applied to the successful derivatization and analysis of PA by GC-MS when present at a 5 μg.mL -1 concentration in a glycerol-rich matrix sample administered during the 48th Proficiency Test administered by the Organisation for the Prohibition of Chemical Weapons (OPCW).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simulated X-Ray Radiographic Performance of a Bismuth-Loaded PVT Array

Recent material advancements in organic plastic scintillators enable marked increases in material detection efficiency, light yield, and pulse shape discrimination properties. These advances may resolve significant capability gaps for lowcost, portable, and durable dual-particle imaging (DPI) systems for nuclear safety, security, and safeguard purposes. One such material, a 21% bismuth-loaded polyvinyl toluene (BiPVT), is computationally evaluated as a small, pixelated radiographic array using Monte Carlo N-Particle (MCNP) and Zemax OpticStudio, and it is compared to identical evaluations of EJ-200 and EJ-256 arrays. MCNP software enables estimates of particle interaction and energy deposition, while OpticStudio computes optical light transport within each material. Here, computational estimates of spatial resolution and relative light collection at 370 kVp are found to agree with experimental results for both EJ-200 and EJ-256 arrays, thereby validating predictions of the same for the BiPVT array. As such, for equivalent exposures at 370 kVp, a BiPVT array may provide ~20× the light collection expected from EJ-200 and ~10× that expected from EJ-256. Similar comparisons of estimated light collection are also computed at 150 and 270 kVp, and these results suggest that BiPVT will provide significantly improved performance over EJ-200 and EJ-256 across all energies practical for portable X-ray radiography.

42 ENGINEERING↗

Autonomously Responsive Membranes for Chemical Warfare Protection

Stimuli-responsive materials offer new opportunities to resolve long-standing material challenges and are rapidly gaining pivotal roles in diverse applications. For example, smart protective garments that rapidly transport water vapor and autonomously block chemical threats are expected to enable an effective new paradigm of adaptive personal protection. However, the incorporation of these seemingly incompatible properties into a single responsive system remains elusive. Herein, a bistable membrane that can rapidly, selectively, and reversibly transition from a highly breathable state in a safe environment to a chemically protective state when exposed to organophosphate threats such as sarin is demonstrated. Dynamic response to chemical stimuli is achieved through the physical collapse of an ultrathin copolymer layer on the membrane surface, which efficiently gates transport through membrane pores composed of single-walled carbon nanotubes (SWNTs). The adoption of nanometer-wide SWNTs for ultrafast moisture conduction enables a simultaneous boost in size-sieving selectivity and water-vapor permeability by decreasing nanotube diameter, thereby overcoming the breathability/protection trade-off that limits conventional membrane materials. Adaptive multifunctional membranes based on this platform greatly extend the active use of a protective garment and present exciting opportunities in many other areas including separation processes, sensing, and smart delivery.

36 MATERIALS SCIENCE↗

Performance of High Stopping Power Bismuth-Loaded Plastic Scintillators for Radiation Portal Monitors

Plastic scintillators are widely used in radiation portal monitors because of their low cost and availability in large sizes. However, due to their low density and low effective atomic number (Z), they offer low intrinsic efficiency and little spectroscopic information. The addition of high-Z constituents to these plastics can greatly increase both their total stopping power and the amount of photoelectric absorption, leading to full-energy deposition and thus useful gamma spectra. Herein, we present the performance of the latest formulation of Bi-loaded plastic scintillators showing their useful spectroscopic information up to relatively high energy (~1 MeV) due to their high stopping power compared to the current commercially available plastics. These Bi-loaded plastics use 20 weight percent (wt%) Bi-pivalate (8 wt% elemental Bi) dissolved in polyvinyltoluene (PVT) matrix and conventional fast fluors (~10 ns decay time). These Bi-loaded plastics achieve up to approximately 6000 photons/MeV and have been produced in sizes up to 17 in 3 . The performance of these Bi-loaded plastics is also demonstrated in the existing portal monitor hardware (Rapiscan Model TSA Trainer 770) showing the possibility to provide improved sensitivity as a drop-in replacement with continued scale-up.

42 ENGINEERING↗