Design and characterization of a phonon-mediated cryogenic particle detector with an eV-scale threshold and 100 keV-scale dynamic range

We present the design and characterization of a cryogenic phonon-sensitive Si detector exploiting the Neganov-Tromov-Luke effect to detect single-charge excitations. This device achieved 2.65(2) eV phonon energy resolution when operated without a voltage bias across the crystal and a corresponding charge resolution of 0.03 electron-hole pairs at 100 V bias. With a continuous-readout data acquisition system and an oine optimum-filter trigger, we obtain a 9.2 eV threshold with a trigger rate of the order of 20 Hz. The detector's energy scale is calibrated up to 120 keV using an energy estimator based on the pulse area. The high performance of this device allows its application to different fields where excellent energy resolution, low threshold, and large dynamic range are required, including dark matter searches, precision measurements of coherent neutrino-nucleus scattering, and ionization yield measurements.

Ren, R↗

Constraints on Lightly Ionizing Particles from CDMSlite

The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) achieved effcient detection of very small recoil energies in its germanium target, resulting in sensitivity to Lightly Ionizing Particles (LIPs) in a previously unexplored region of charge, mass, and velocity parameter space. We report first direct-detection limits on the vertical intensity of cosmogenically-produced LIPs with an electric charge smaller than e/(3x10^5), as well as the strongest limits for charge <= e/160, with a minimum vertical intensity of 1.36 x 10^-7 cm^-2s^-1sr^-1 at charge e/160. These results apply over a wide range of LIP masses (5 MeV/c^2 to 100 TeV/c^2) and cover a wide range of beta-gamma values (0.1--10^6), thus excluding non-relativistic LIPs with beta-gamma as small as 0.1 for the first time.

Alkhatib, I↗

Light Dark Matter Search with a High-Resolution Athermal Phonon Detector Operated Above Ground

We present limits on spin-independent dark matter-nucleon interactions using a 10.6 g silicon athermal phonon detector with a baseline energy resolution of 4.92 +/- 0.01 eV. This exclusion analysis sets the most stringent dark matter-nucleon cross-section limits for masses from 87--140 MeV/c^2 , with a raw exposure of 9.9 g d acquired at an above-ground facility. This work illustrates the scientic potential of athermal phonon sensors with eV-scale energy resolution for future dark matter searches.

Alkhatib, I↗

Constraints on dark photons and axionlike particles from the SuperCDMS Soudan experiment

We present an analysis of electron recoils in cryogenic germanium detectors operated during the SuperCDMS Soudan experiment. The data are used to set new constraints on the axioelectric coupling of axion-like particles and the kinetic mixing parameter of dark photons, assuming the respective species constitutes all of the galactic dark matter. This study covers the mass range from 40 eV/$c^2$ to 500 eV/$c^2$ for both candidates, excluding previously untested parameter space for masses below ~1 keV/$c^2$. For the kinetic mixing of dark photons, values below $10^{-15}$ are reached for particle masses around 100 eV/$c^2$; for the axioelectric coupling of axion-like particles, values below $10^{-12}$ are reached for particles with masses in the range of a few-hundred eV/$c^2$.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Millikelvin Cryogenics at Fermilab

Millikelvin cryogenics is an emergent area for Fermilab with broad applications in particle detection for the cosmic frontier and quantum information science. Fermilab Cryogenic Engineering currently supports multiple experiments, including the SuperCDMS SNOLAB and ADMX dark matter experiments, along with several millikelvin test facilities. More programs are expected to come online in future.

43 PARTICLE ACCELERATORS↗