Search NASA⌕ Search

Engineering topics

Holloway, Michael Andrew

Publications and source records attributed to Holloway, Michael Andrew.

Response to Comment on “Radiation-Belt Remediation Using Space-Based Antennas and Electron Beams” by G. Ganguli and C. Crabtree

Ganguli and Crabtree have written a comment about a recent article by the authors listed above on radiation-belt remediation. They have objected to our evaluation of the Naval Research Laboratory’s chemical release concept which states that this concept may be impractical due to an apparently low overall efficiency. In their comment, they provide a scientific argument and refer to the published literature to counter our statement. Here, in this response, we provide more details on our numerical calculations and experimental results which led to this evaluation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Space-Borne Electron Accelerator Design

Renewed interest in active experiments with relativistic particle beams in space has led to the development of solid-state radio-frequency (RF) linear accelerators (linac) that can deliver MeV electron beams but operate with low-voltage DC power supplies. The solid-state RF amplifiers used to drive the accelerator are known as high-electron mobility transistors (HEMTs), and at C-band (5–6 GHz) are capable of generating up to 500 watts of RF power at 10% duty factor in a small package, i.e., the size of a postage stamp. In operation, the HEMTs are powered with 50 V DC as their bias voltage; they thus can tap into the spacecraft batteries or electrical bus as the primary power source. In this paper we describe the initial testing of a compact space-borne RF accelerator consisting of individual C-band cavities, each independently powered by a gallium nitride (GaN) HEMT. We show preliminary test results that demonstrate the beam acceleration in a single C-band cavity powered by a single HEMT operating at 10% duty factor. An example of active beam experiments in space that could benefit from the HEMT-powered accelerators is the proposed Magnetosphere-Ionosphere Connection (CONNEX) experiment (Dors et al., 2017).

43 PARTICLE ACCELERATORS↗

Beam Diagnostics Report for the Thermal Test Conducted on 3/9/2016

The thermal test OTR data revealed several issues with the beam focus and the target window itself. The oxidation of the target window and the prominence of a scratch across the center of the window makes it impossible to accurately measure the beam profile and size.

43 PARTICLE ACCELERATORS↗

Report on the Radiation Effects Testing of the Infrared and Optical Transition Radiation Camera Systems

Presented in this report are the results tests performed at Argonne National Lab in collaboration with Los Alamos National Lab to assess the reliability of the critical 99 Mo production facility beam monitoring diagnostics. The main components of the beam monitoring systems are two cameras that will be exposed to radiation during accelerator operation. The purpose of this test is to assess the reliability of the cameras and related optical components when exposed to operational radiation levels. Both X-ray and neutron radiation could potentially damage camera electronics as well as the optical components such as lenses and windows. This report covers results of the testing of component reliability when exposed to X-ray radiation. With the information from this study we provide recommendations for implementing protective measures for the camera systems in order to minimize the occurrence of radiation-induced failure within a ten month production run cycle.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IR Camera Report for the 7 Day Production Test

The following report gives a summary of the IR camera performance results and data for the 7 day production run that occurred from 10 Sep 2015 thru 16 Sep 2015. During this production run our goal was to see how well the camera performed its task of monitoring the target window temperature with our improved alignment procedure and emissivity measurements. We also wanted to see if the increased shielding would be effective in protecting the camera from damage and failure.

43 PARTICLE ACCELERATORS↗

Water Cooled Mirror Design

This design is intended to replace the current mirror setup being used for the NorthStar Moly 99 project in order to monitor the target coupon. The existing setup has limited movement for camera alignment and is difficult to align properly. This proposed conceptual design for a water cooled mirror will allow for greater thermal transfer between the mirror and the water block. It will also improve positioning of the mirror by using flexible vacuum hosing and a ball head joint capable of a wide range of motion. Incorporating this design into the target monitoring system will provide more efficient cooling of the mirror which will improve the amount of diffraction caused by the heating of the mirror. The process of aligning the mirror for accurate position will be greatly improved by increasing the range of motion by offering six degrees of freedom.

42 ENGINEERING↗

Production Facility SCADA Design Report

The following report covers FY 14 activities to develop supervisory control and data acquisition (SCADA) system for the Northstar Moly99 production facility. The goal of this effort is to provide Northstar with a baseline system design.

42 ENGINEERING↗

Exploring Alternative Non-contact temperature measurements for 99 Mo production facility NorthStar FY14 Activity 5, Deliverable 2

We have conducted an experiment to explore an alternative non-contact method of measuring the Inconel target window temperature. This experiment involves using a standard color camera to observe the visible light emitted from the Inconel target window at high heat in order to estimate the window temperature. The safety limit to prevent target window failure is 700 °C and therefore we need a reliable and accurate method of measuring temperature especially in the range of 600 °C to 700 °C if it is to replace the IR camera. In this temperature range the window will emit a significant amount of black body radiation within the visible range and hence the idea of using a color camera. The goal is to see if the shift in window color (determined by the RBG pixel values of the camera) as the target window is heated to 700 °C can be calibrated to the temperature.The reasons for exploring this as an alternative to an IR are camera are: significant cost reduction and potentially less complicated to calibrate.

42 ENGINEERING↗