Search NASA⌕ Search

Engineering topics

Holt, S.

Publications and source records attributed to Holt, S..

Construction of precision wire readout planes for the Short-Baseline Near Detector (SBND)

The Short-Baseline Near Detector time projection chamber is unique in the design of its charge readout planes. These anode plane assemblies (APAs) have been fabricated and assembled to meet strict accuracy and precision requirements: wire spacing of 3 mm ± 0.5 mm and wire tension of 7 N ± 1 N across 3,964 wires per APA, and flatness within 0.5 mm over the 4 m × 2.5 m extent of each APA . Here, we describe the design, manufacture and assembly of these key detector components, with a focus on the quality assurance at each stage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal detection of X-rays

The development of calorimeters is described in terms of their proposed application to sounding-rocket investigations of cosmic X-ray sources. The fundamental theory of the energy resolution of the devices is given, and general discussions are presented regarding the limitations associated with the materials used and available thermometer types. Also given are data describing electrical nonlinearity as a function of temperature, thermistor sensitivity, and heat capacity, as well as data regarding the excess noise that aids in the conduction process. Cryogenic calorimeters based on doped semiconductor thermistors are found to be limited, although thermal detectors have important applications to high-resolution laboratory spectroscopy. Electrical nonlinearity and the excess noise are found to be important for obtaining optimum heat capacity in the thermistor.

Mccammon, D.↗

Spectroscopy of two BL Lacertae objects

As part of a continuing program of observations of Bl Lac objects, the IUE cameras were used to look at PKS 0548-322 and PKS 2155-304. The spectra obtained are well described by power laws with alpha approximately 0.8 in each case. For each object, one set of simultaneous X-ray data was obtained using the solid state spectrometer (SSS) on the Einstein Observatory. These data show that the power law extends from ultraviolet frequencies into the X-ray regime, although it steepens slightly for PKS 2155-304. Both objects are variable in the ultraviolet and/or X-ray; in neither case does the small spectral variability appear to correlate with the intensity variability. The overall spectrum of these objects is interpreted in light of a synchrotron self-Compton model with relativistic beaming.

Urry, C. M.↗

Extended-bandwidth X-ray observations of Cygnus X-1

An energy- and time-resolved observation of Cyg X-1, sensitive from 0.15 to 20 keV, is reported which was performed to investigate the spectrum and time variability of the flux at low X-ray energies. Data in the band from 1.5 to 42 keV, obtained in two previous rocket flights, are reanalyzed to search for any energy dependence of the time signature. No such energy dependence is found, so the explanation of the observed low-energy excess of Cyg X-1 as emission from an extended region separate from the high-energy source is rendered untenable. The evident stability of the power-law spectrum of Cyg X-1 through the observed shot-noise variation is shown to suggest that the spectrum has a Comptonization origin. It is concluded that there is no obvious analogy to be made between Cyg X-1 and X-ray bursters.

Priedhorsky, W.↗

Elemental abundances in a type I SNR

The solid state spectrometer on the HEAO-2 X-ray observatory observed the X-ray spectrum of Tycho's SNR. The observations show a relative excess of line emission from Si, S, and Ar by or = 6 compared to that expected from a plasma of solar composition in collisional equilibrium and by a factor of or = 3 compared to Cas A. Similar excesses are not found for line emission from Mg and Fe. The data suggest that the SN observed by Tycho in 1572 produced significant amounts of Si group elements but did not eject large amounts of Fe as predicted by some models of Type I SN events.

Becker, R. H.↗

The cosmic X-ray experiment aboard HEAO-1

The cosmic X-ray experiment aboard the HEAO-1 observatory is described, The instrument consists of six gas proportional counters of three types nominally covering the energy ranges of 0.15 keV, 1.2-20 keV, and 2.5-60 keV. The two low energy detectors have about 400 sq cm open area each while the four others have about 800 sq cm each. A novel feature of this experiment is the dual field of view collimators that allow the unambiguous determination of instrument internal background and diffuse X-ray brightness. Instrument characteristics and early performance are discussed.

Rothschild, R.↗

The cosmic X-ray experiment aboard HEAO-1

The HEAO-1 A-2 experiment, designed to study the large scale structure of the galaxy and the universe at X-ray energies is described. The instrument consists of six gas proportional counters of three types nominally covering the energy ranges of 0.15-3 keV, 1.2-20 keV, and 2.5-60 keV. The two low energy detectors have about 400 sq cm open area each while the four others have about 800 sq cm each. Dual field of view collimators allow the unambiguous determination of instrument internal background and diffuse X-ray brightness. Instrument characteristics and early performance are discussed.

Rothschild, R. E.↗

The fluctuating and isotropic components of the cosmic X-ray background

Spatial fluctuations in the surface brightness of the extragalactic hard X-ray sky that are characteristic of distant unresolved discrete sources as well as the possible clumpiness of a hot universal plasma are being studied with the HEAO-1 A-2 experiment. The energy spectrum for this fluctuating component is directly compared to that of the isotropic background. The spectra of identified extragalactic objects recently obtained with experiments aboard both OSO-8 and HEAO-1 are used for examining the contribution of such sources to this fluctuating component of the background.

Boldt, E.↗

OSO-8 X-ray observations of AM Herculis

Results are reported for hard X-ray observations of the binary system AM Her, which were coincident with soft X-ray and ground-based optical measurements. In the 2-60-keV band, variability was detected with an eclipse during phases 0.5 to 0.7 with respect to the 0.12892-day optical minima, synchronous with the known soft X-ray eclipse. The 2-60-keV uneclipsed flux was 9.5 by 10 to the -10th power erg/sq cm per sec, of which 86% lies above 10 keV. Thus, AM Her contains a hard source located near the similarly eclipsed soft X-ray source. The X-ray data are interpreted in terms of thermal bremsstrahlung from accretion onto a white dwarf.

Swank, J.↗

What is special about Cygnus X-1 - Black holes in theory and observation: X-ray observations

Of the eight X-ray sources now known which may be associated with binary stellar systems, Cygnus X-1 is the most likely candidate for being a black hole. The X-ray evidence from several experiments is reviewed, with special emphasis on those characteristics which appear to distinguish Cygnus X-1 from other compact X-ray emitting objects. Data are examined within the context of a model in which millisecond bursts (Rothschild et al., 1974) are superposed on shot-noise fluctuations (Terrell, 1972) arising from 'events' of durations on the order of a second. Possible spectral-temporal correlations are investigated which indicate new measurements that need to be made in future experiments.

Boldt, E.↗