Search NASA⌕ Search

Engineering topics

Holtkamp, David B.

Publications and source records attributed to Holtkamp, David B..

Comparison of Simultaneous Shock Temperature Measurements from Three Different Pyrometry Systems

Pyrometry is one of the most prevalent techniques for measuring temperature in shock physics experiments. However, the challenges of applying pyrometry in such highly dynamic environments produces multiple sources of uncertainty that require investigation. An outstanding question is the degree of agreement between different pyrometers and different experiments. Here we report a series of novel plate impact experiments with simultaneous thermal radiance measurements using three different multi-wavelength optical pyrometry systems, each with different spatial and temporal resolutions, on samples shocked to identical states. We compare the temperatures measured by each system and their associated uncertainties using a number of emissivity assumptions. The results shown that the measurements from all three systems agree within uncertainty. Furthermore, some non-thermal light contamination was observed despite a number of prevention measures.

36 MATERIALS SCIENCE↗

Photonic Doppler Velocimetry Probe Designed with Stereo Imaging

The velocity distribution of an imploding curved surface is measured with a miniature fiber-optic probe. The probe uses fiber matrix arrays that are focused onto different regions of this curved surface. A pyramid reflector deflects the interrogation onto specific regions of this curved surface. The fiber arrays record velocity along several hundred lines of sight with sub-nanosecond resolution. Reflected light from each spot on the moving surface is Doppler shifted with a small portion of this light propagating backwards through the launching fiber. The reflected light is mixed with a reference laser in a technique called Photonic Doppler velocimetry, providing continuous time records. Within the probe, seven groups of miniature optical relay lenses are grouped into a close-packed array, allowing the interrogation of seven regions of interest. A six-faceted pyramid reflector with a conical hole drilled into its center is used to direct the light beams onto different regions. To minimize back reflections, the fiber matrix arrays are index matched onto the first relay lens made of fused silica. The optical lens design minimizes the laser beam diameters and also provides excellent imaging capabilities. Therefore, two of the fiber matrix arrays are replaced by coherent bundles for stereo imaging recorded by a high-speed framing camera. This requires additional cutouts of the pyramid reflector to allow imaging overlap. Six additional 1.5 mm diameter incoherent bundles are attached to the edges of the pyramid reflector and are used for illumination. Precision metrology on the direction cosines of the trajectories is measured to satisfy environmental requirements for vibration and temperature.

photonic doppler velocimetry, PDV, pyramid reflect↗

Ejecta model development at pRad (u)

In July 2009 we fielded three explosively (HE) driven Richtmyer-Meshkov instability experiments at the LANSCE Proton Radiography Facility (pRad), and in August of 2009 we fielded one flyer plate experiment on the pRad 40 mm powder gun. One HE experiment was done in vacuum, and the other two within four atmospheres of noble gasses: Xe and Ne. These two gases were chosen to study the viscous effects on ejecta formation. It is unexpected, but the viscosity {eta} of Ne is twice that of Xe, and, due to the atomic mass difference between the two, the kinematic viscosity ({eta}/{rho}) of Ne is about ten times that of Xe. The results showed that ejecta formation is sensitively linked to the gas density, which implies that the Weber number is more important in ejecta formation than the Reynolds number.

99 GENERAL AND MISCELLANEOUS↗