NSLS-II Linac Klystron Filament Failure Analysis
The NSLS-II linear accelerator uses the TH2100A klystron tube. One tube has failed with broken window with less than 8000 hours. The tuning (impedance matching) posts were clearly bent, indicating that this tube had a mismatch at the window that was tuned out at the factory. None of our other tubes arrived like this. It is not clear if this was a contributing factor to the failure. This tube was purchased by BNL and installed after linac commissioning to verify operation. Tube delivered with linac held as spare and re-installed when this tube failed.