Search for low-mass electron-recoil dark matter using a single-charge sensitive SuperCDMS-HVeV Detector

We present constraints on low mass dark matter-electron scattering and absorption interactions using a SuperCDMS high-voltage eV-resolution (HVeV) detector. Data were taken underground in the NEXUS facility located at Fermilab with an overburden of 225 meters of water equivalent. The experiment benefits from the minimizing of luminescence from the printed circuit boards in the detector holder used in all previous HVeV studies. A blind analysis of $6.1\,\mathrm{g\cdot days}$ of exposure produces exclusion limits for dark matter-electron scattering cross-sections for masses as low as $1\,\mathrm{MeV}/c^2$, as well as on the photon-dark photon mixing parameter and the coupling constant between axion-like particles and electrons for particles with masses $>1.2\,\mathrm{eV}/c^2$ probed via absorption processes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modeling and Characterization of TES-Based Detectors for the Ricochet Experiment

Coherent elastic neutrino-nucleus scattering (CE nu NS) offers a valuable approach in searching for physics beyond the standard model. The Ricochet experiment aims to perform a precision measurement of the CE nu NS spectrum at the Institut Laue-Langevin nuclear reactor with cryogenic solid-state detectors. The experiment plans to employ an array of cryogenic thermal detectors, each with a mass of around 30 g and an energy threshold of below 100 eV. The array includes nine detectors read out by transition-edge sensors (TES). These TES-based detectors will also serve as demonstrators for future neutrino experiments with thousands of detectors. In this article, we present an update on the characterization and modeling of a prototype TES detector.

Chang, C. L.↗

Properties of Low Tc AlMn TES

Low Tc AlMn transition-edge sensors (TESs) have been developed as sensitive thermometers for the Q-Array, which will use superconducting targets to measure the coherent elastic neutrino nucleus scattering spectrum in the RICOCHET experiment. The TESs are made of manganese-doped aluminum with a titanium and gold antioxidation layer. A prototype TES thermometer consists of two TESs in parallel, an input gold pad in metallic contact with the TESs and an output gold pad and gold thermal link meanders, which are each designed to control the flow of heat through the TESs. We have fabricated and measured low TC AlMn TES chips with or without thermal flow control structures. We present TC measurements of the TESs after the initial fabrication and further TC tuning by re-heating and summarize the thermal property studies of the prototype TES thermometer by measuring I-V curves and complex impedance.

Coherent elastic neutrino nucleus scattering, Cryo↗

First demonstration of 30 eVee ionization energy resolution with RICOCHET germanium cryogenic bolometers

The future RICOCHET experiment aims to search for new physics in the electroweak sector by measuring the Coherent Elastic Neutrino-Nucleus Scattering process from reactor antineutrinos with high precision down to the sub-100 eV nuclear recoil energy range. While the RICOCHET collaboration is currently building the experimental setup at the reactor site, it is also finalizing the cryogenic detector arrays that will be integrated into the cryostat at the Institut Laue Langevin in early 2024. In this paper, we report on recent progress from the Ge cryogenic detector technology, called the CryoCube. More specifically, we present the first demonstration of a 30 eVee (electron equivalent) baseline ionization resolution (RMS) achieved with an early design of the detector assembly and its dedicated High Electron Mobility Transistor (HEMT) based front-end electronics with a total input capacitance of about 40 pF. This represents an order of magnitude improvement over the best ionization resolutions obtained on similar phonon-and-ionization germanium cryogenic detectors from the EDELWEISS and SuperCDMS dark matter experiments, and a factor of three improvement compared to the first fully-cryogenic HEMT-based preamplifier coupled to a CDMS-II germanium detector with a total input capacitance of 250 pF. Additionally, we discuss the implications of these results in the context of the future RICOCHET experiment and its expected background mitigation performance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Measurement of the Nuclear-Recoil Ionization Yield in Silicon at 100 eV

We measured the nuclear-recoil ionization yield in silicon with a cryogenic phonon-sensitive gram-scale detector. Neutrons from a mono-energetic beam scatter off of the silicon nuclei at angles corresponding to energy depositions from 4 keV down to 100 eV, the lowest energy probed so far. The results show no sign of an ionization production threshold above 100 eV. In conclusion, these results call for further investigation of the ionization yield theory and a comprehensive determination of the detector response function at energies below the keV scale.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

G4CMP: Condensed matter physics simulation using the G$\scriptsize{\mathrm{EANT}}$4 toolkit

G4CMP simulates phonon and charge transport in cryogenic semiconductor crystals using the Geant4 toolkit. The transport code is capable of simulating the propagation of acoustic phonons as well as electron and hole charge carriers. Herein processes for anisotropic phonon propagation, oblique charge-carrier propagation, and phonon emission by accelerated charge carriers are included. The simulation reproduces theoretical predictions and experimental observations such as phonon caustics, heat-pulse propagation times, and mean charge-carrier drift velocities. In addition to presenting the physics and features supported by G4CMP, this report outlines example applications from the dark matter and quantum information science communities. These communities are applying G4CMP to model and design devices for which the energy transported by phonons and charge carriers is germane to the performance of superconducting instruments and circuits placed on silicon and germanium substrates. The G4CMP package is available to download from GitHub: github.com/kelseymh/G4CMP.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast neutron background characterization of the future Ricochet experiment at the ILL research nuclear reactor

Abstract The future Ricochet experiment aims at searching for new physics in the electroweak sector by providing a high precision measurement of the Coherent Elastic Neutrino-Nucleus Scattering (CENNS) process down to the sub-100 eV nuclear recoil energy range. The experiment will deploy a kg-scale low-energy-threshold detector array combining Ge and Zn target crystals 8.8 m away from the 58 MW research nuclear reactor core of the Institut Laue Langevin (ILL) in Grenoble, France. Currently, the Ricochet Collaboration is characterizing the backgrounds at its future experimental site in order to optimize the experiment’s shielding design. The most threatening background component, which cannot be actively rejected by particle identification, consists of keV-scale neutron-induced nuclear recoils. These initial fast neutrons are generated by the reactor core and surrounding experiments (reactogenics), and by the cosmic rays producing primary neutrons and muon-induced neutrons in the surrounding materials. In this paper, we present the Ricochet neutron background characterization using $$^3$$ 3 He proportional counters which exhibit a high sensitivity to thermal, epithermal and fast neutrons. We compare these measurements to the Ricochet Geant4 simulations to validate our reactogenic and cosmogenic neutron background estimations. Eventually, we present our estimated neutron background for the future Ricochet experiment and the resulting CENNS detection significance. Our results show that depending on the effectiveness of the muon veto, we expect a total nuclear recoil background rate between 44 ± 3 and 9 ± 2 events/day/kg in the CENNS region of interest, i.e. between 50 eV and 1 keV. We therefore found that the Ricochet experiment should reach a statistical significance of 4.6 to 13.6 $$\sigma $$ σ for the detection of CENNS after one reactor cycle, when only the limiting neutron background is considered.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗