Search NASA⌕ Search

Engineering topics

Hoover, Andrew S

Publications and source records attributed to Hoover, Andrew S.

High-resolution microcalorimeter detectors as a tool in the future of nuclear safeguards

New measurements are presented from the LANL-NIST microcalorimeter array for two standard plutonium sources. The results demonstrate substantially smaller error bars obtained from the spectral analysis program FRAM. Some areas of improvement to the analysis technique have been identified, indicating that the micro calorimeter results can be improved upon. These results support the viability of a device for performing real nuclear safeguards measurements in the near future. The challenge of providing reliably accurate and precise data is a critical component of any safeguards initiative. In the realm of nuclear safeguards, this is an especially daunting task since inaccurate and/or imprecise data could have very serious international consequences. As such, there is a constant drive within the community to establish better measurement and analysis techniques in order to further reduce the associated errors and uncertainties. Even with todays state of the art equipment, measurement uncertainties can extend to several significant quantities worth of material over a relatively modest period of time. Furthermore, there is a strong desire for improved nondestructive analysis techniques in order to reduce both the cost, turnover rate, and inconvenience of destructive analyses. One promising new technology that may help to realize these goals is that of gamma-ray microcalorimeter detectors. The hallmark quality of this new technique is the ability to achieve energy resolution nearly an order of magnitude better than typical planar high-purity germanium (HPGe) detectors. Such an improvement may help reduce uncertainties associated with, for instance, plutonium isotopics or uranium enrichment measurements. This may, in turn, help to reduce uncertainties in total plutonium and/or uranium content in a given sample without the need for destructive analysis. In this paper, we will describe this new detector technology as well as some recent measurements carried out with the LANL-NIST gamma-ray microcalorimeter ({micro}cal) array. Discussion will focus on the capabilities of this technology as well as the progress toward a practical measurement device.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

THE FERMI GAMMA-RAY BURST MONITOR

The Gamma-Ray Burst Monitor (GBM) will significantly augment the science return from the Fermi Observatory in the study of gamma-ray bursts (GRBs). The primary objective of GBM is to extend the energy range over which bursts are observed downward from the energy range of the Large Area Telescope (LAT) on Fermi into the hard X-ray range where extensive previous data sets exist. A secondary objective is to compute burst locations onboard to allow re-orienting the spacecraft so that the LAT can observe delayed emission from bright bursts. GBM uses an array of 12 sodium iodide scintillators and two bismuth germanate scintillators to detect gamma rays from {approx}8 keV to {approx}40 MeV over the full unocculted sky. The onboard trigger threshold is {approx}0.7 photons cm{sup -2} s{sup -1} (50-300 keV, 1 s peak). GBM generates onboard triggers for {approx}250 GRBs per year.

79 ASTRONOMY AND ASTROPHYSICS↗

On-Orbit Performance of the Fermi Gamma-Ray Burst Monitoi

The Fermi Gamma Ray Burst Monitor (GBM) enhances the science return from the Fermi mission by providing observations of GRBs in the energy range 8 keV to 40 MeV, thereby extending GRB spectra three decades below the Large Area Telescope (LAT) threshold of {approx}20 MeV. GBM employs twelve sodium iodide scintillation detectors and two bismuth germinate scintillation detectors to observe the full unocculted sky. The flight software localizes GRBs and can generate a request to autonomously repoint the spacecraft to place a burst within the LAT field of view. GBM has a trigger threshold of 0.74 photons-cm{sup -2}-s{sup -1} and triggers on {approx}260 bursts per year, as well as a variety of other gamma-ray transients.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation and modeling for the stand-off radiation detection system (SORDS) using GEANT4

A Stand-Off Radiation Detection System (SORDS) is being developed through a joint effort by Raytheon, Los Alamos National Laboratory, Bubble Technology Industries, Radiation Monitoring Devices, and the Massachusetts Institute of Technology, for the Domestic Nuclear Detection Office (DNDO). The system is a mobile truck-based platform performing detection, imaging, and spectroscopic identification of gamma-ray sources. A Tri-Modal Imaging (TMI) approach combines active-mask coded aperture imaging, Compton imaging, and shadow imaging techniques. Monte Carlo simulation and modeling using the GEANT4 toolkit was used to generate realistic data for the development of imaging algorithms and associated software code.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of plutonium in spent nuclear fuel by self-induced x-ray fluorescence

Direct measurement of the plutonium content in spent nuclear fuel is a challenging problem in non-destructive assay. The very high gamma-ray flux from fission product isotopes overwhelms the weaker gamma-ray emissions from plutonium and uranium, making passive gamma-ray measurements impossible. However, the intense fission product radiation is effective at exciting plutonium and uranium atoms, resulting in subsequent fluorescence X-ray emission. K-shell X-rays in the 100 keV energy range can escape the fuel and cladding, providing a direct signal from uranium and plutonium that can be measured with a standard germanium detector. The measured plutonium to uranium elemental ratio can be used to compute the plutonium content of the fuel. The technique can potentially provide a passive, non-destructive assay tool for determining plutonium content in spent fuel. In this paper, we discuss recent non-destructive measurements of plutonium X-ray fluorescence (XRF) signatures from pressurized water reactor spent fuel rods. We also discuss how emerging new technologies, like very high energy resolution microcalorimeter detectors, might be applied to XRF measurements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Modeling of x-ray fluorescence using MCNPX and Geant4

X-Ray Fluorescence (XRF) is one of thirteen non-destructive assay techniques being researched for the purpose of quantifying the Pu mass in used fuel assemblies. The modeling portion of this research will be conducted with the MCNPX transport code. The research presented here was undertaken to test the capability of MCNPX so that it can be used to benchmark measurements made at the ORNL and to give confidence in the application of MCNPX as a predictive tool of the expected capability of XRF in the context of used fuel assemblies. The main focus of this paper is a code-to-code comparison between MCNPX and Geant4 code. Since XRF in used fuel is driven by photon emission and beta decay of fission fragments, both terms were independently researched. Simple cases and used fuel cases were modeled for both source terms. In order to prepare for benchmarking to experiments, it was necessary to determine the relative significance of the various fission fragments for producing X-rays.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High rate pulse processing algorithms for microcalorimeters

It has been demonstrated that microcalorimeter spectrometers based on superconducting transition-edge-sensor can readily achieve sub-100 eV energy resolution near 100 keV. However, the active volume of a single microcalorimeter has to be small to maintain good energy resolution, and pulse decay times are normally in the order of milliseconds due to slow thermal relaxation. Consequently, spectrometers are typically built with an array of microcalorimeters to increase detection efficiency and count rate. Large arrays, however, require as much pulse processing as possible to be performed at the front end of the readout electronics to avoid transferring large amounts of waveform data to a host computer for processing. In this paper, they present digital filtering algorithms for processing microcalorimeter pulses in real time at high count rates. The goal for these algorithms, which are being implemented in the readout electronics that they are also currently developing, is to achieve sufficiently good energy resolution for most applications while being (a) simple enough to be implemented in the readout electronics and (b) capable of processing overlapping pulses and thus achieving much higher output count rates than the rates that existing algorithms are currently achieving. Details of these algorithms are presented, and their performance was compared to that of the 'optimal filter' that is the dominant pulse processing algorithm in the cryogenic-detector community.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Issues in energy calibration, nonlinearity, and signal processing for gamma-ray microcalorimeter

Issues regarding the energy calibration of high dynamic range microcalorimeter detector arrays are presented with respect to new results from a minor actinide-mixed oxide radioactive source. The need to move to larger arrays of such detectors necessitates the implementation of automated analysis procedures, which turn out to be nontrivial due to complex calibration shapes and pixel-to-pixel variability. Some possible avenues for improvement, including a more physics-based calibration procedure, are suggested.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cryogenic microcalorimeter system for ultra-high resolution alpha-particle spectrometry

Microcalorimeters have been shown to yield unsurpassed energy resolution for alpha spectrometry, up to 1.06 keV FWHM at 5.3 MeV. These detectors use a superconducting transition-edge sensor (TES) to measure the temperature change in an absorber from energy deposited by an interacting alpha particle. Our system has four independent detectors mounted inside a liquid nitrogen/liquid helium cryostat. An adiabatic demagnetization refrigerator (ADR) cools the detector stage to its operating temperature of 80 mK. Temperature regulation with {approx}15 uK peak-to-peak variation is achieved by PID control of the ADR. The detectors are voltage-biased, and the current signal is amplified by a commercial SQUID readout system and digitized for further analysis, This paper will discuss design and operation of our microcalorimeter alpha spectrometer, and will show recent results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗