Search NASASearch

Engineering topics

Hopkins, Richard A.

Publications and source records attributed to Hopkins, Richard A..

The X-ray Spectrometer - A cryogenic instrument on the Advanced X-ray Astrophysics Facility

The X-ray Spectrometer (XRS) is an instrument on the Advanced X-ray Astrophysics Facility (AXAF), the third of NASA's Great Observatories scheduled for launch in 1998. The XRS detectors have a resolution of approximately 10 eV over the range 0.3 - 10 keV. To achieve this resolution, the detectors are maintained at or below 0.1 Kelvin using an adiabatic demagnetization refrigerator inside a superfluid helium dewar. In addition, split-Stirling-cycle mechanical coolers are used to extend the anticipated on-orbit helium lifetime to a minimum of 4 years. This paper describes the challenges of developing this hybrid cryogenic system and presents an overview of the current design of the system.

Breon, Susan R.

5-year lifetime hybrid superfluid helium dewar for the AXAF X-Ray Spectrometer (XRS)

The focal plane of the AXAF X-Ray Spectrometer requires an operating temperature of 0.1 K with a mission lifetime of 5 yrs. This demanding task is accomplished with a hybrid cryogenic subsystem consisting of mechanical coolers, a superfluid helium dewar and an adiabatic demagnetization refrigerator. By using mechanical coolers to remove heat from the dewar outer vapor-cooled shield, a 5-yr lifetime is achievable with only a 483-liter tank. This approach takes advantage of flight-proven, high-performance dewar technology and recent success in the development of split, Stirling-cycle mechanical coolers. Although the dewar design principles are similar to those used previously, parasitic heat flow is reduced to a new level by an optimized tension strap support system and careful attention to insulation system details. The benefit of the mechanical coolers is maximized by dewar interface design features that minimize parasitic heating and thermal impedance of the coupling. The dewar design and thermal performance analysis are discussed. Helium lifetime sensitivities and the effects of mechanical cooler failures are predicted.

Nieczkoski, Stephen J.

A design and critical technology issues for on-orbit resupply of superfluid helium

The issues of and the solutions to the critical design and technology areas of the Superfluid Helium On-Orbit Transfer (SHOOT) experiment, presently under development at the NASA Goddard Spaceflight Center, are discussed. Special attention is given to the SHOOT design requirements for the 10,000-liter superfluid He resupply tanker system, the concept details of the system, and the resupply operations and their analysis. A block diagram of the SHOOT system is included along with fluid management schematic and configuration diagrams of the system and its subsystems. A summary of the dewar performance is also presented.

Hopkins, Richard A.

Performance predictions for spaceborne, long-lifetime helium dewars containing large-aperture telescopes

The evolution of design approaches for high-performance superfluid helium dewars containing large-aperture telescopes are discussed. Particular attention is given to thermal-math modeling for the IRAS and the Cosmic Background Explorer (COBE) dewars. Correlation of the recent COBE flight data with the dewar thermal-math model is presented, and apparent predictive deficiencies of the model are discussed.

Hopkins, Richard A.

Cryogenic on-orbit performance of the NASA Cosmic Background Explorer (COBE)

The initial thermal set-up and operation of the dewar for the COBE spacecraft are discussed, focusing on the helium vent system. During the initial cooldown of the dewar from 1.72 K to 1.41 K, short term temperature and pressure oscillations were observed in the porous plug and in the vent line. A detailed flow model describing these oscillations was developed. Attention is also given to the steady state operating mode for the instruments and the dewar, a comparison of the 'mission mode' temperature and power profile of the dewar with the predicted performance, the instrument and spacecraft events affecting the helium boil-off rate, and the methods for determining the helium flow rate and remaining mass measurements.

Volz, Stephen M.

Fluid quantity gaging

A system for measuring the mass of liquid in a tank on orbit with 1 percent accuracy was developed and demonstrated. An extensive tradeoff identified adiabatic compression as the only gaging technique that is independent of gravity or its orientation, and of the size and distribution of bubbles in the tank. This technique is applicable to all Earth-storable and cryogenic liquids of interest for Space Station use, except superfluid helium, and can be applied to tanks of any size, shape, or internal structure. Accuracy of 0.2 percent was demonstrated in the laboratory, and a detailed analytical model was developed and verified by testing. A flight system architecture is presented that allows meeting the needs of a broad range of space fluid systems without custom development for each user.

Mord, Allan J.

Measured ground performance and predicted orbital performance of the superfluid helium dewar for the Cosmic Background Explorer

A critical component of the Cosmic Background Explorer observatory, which is to be lifted to orbit in 1988, is the 650-l superfluid He dewar housing a far-IR absolute spectrophotometer and a diffuse IR background experiment. Attention is presently given to the results of a four-month-long test program encompassing dewar filling verification, vibration characteristics, thermal performance over orbital lifetime, and aperture cover ejection behavior. No significant flaws have been noted; the orbital cryogen lifetime is projected to be 14 months.

Hopkins, Richard A.