Search NASASearch

Engineering topics

Hornung, Hans G.

Publications and source records attributed to Hornung, Hans G..

Two-directional skin friction measurement utilizing a compact internally mounted thin-liquid-film skin friction meter

A new, compact oil film skin friction meter capable of measuring skin friction in two directions has been designed and constructed. The instrument allows the thin liquid film technique to now be applied in flight and in a wider variety of laboratory conditions. The instrument was tested by comparing measurements with those given by a floating element gage in laminar, transitional, and turbulent boundary layers with zero pressure gradient. Both instruments agreed satisfactorily with each other and with the expected curves for the laminar and turbulent boundary layers. Significant differences were at first seen between the oil film meter and two floating element gages in the case of a favorable pressure gradient, but when a correction is applied to account for the normal force acting on the pendulum-type gage, the three instruents are much closer. The directional sensitivity of the oil film gage is also demonstrated.

Seto, Jeffrey A.

Analysis of thermo-chemical nonequilibrium models for carbon dioxide flows

The aerothermodynamics of thermochemical nonequilibrium carbon dioxide flows is studied. The chemical kinetics models of McKenzie and Park are implemented in separate three-dimensional computational fluid dynamics codes. The codes incorporate a five-species gas model characterized by a translational-rotational and a vibrational temperature. Solutions are obtained for flow over finite length elliptical and circular cylinders. The computed flowfields are then employed to calculate Mach-Zehnder interferograms for comparison with experimental data. The accuracy of the chemical kinetics models is determined through this comparison. Also, the methodology of the three-dimensional thermochemical nonequilibrium code is verified by the reproduction of the experiments.

Rock, Stacey G.

Performance data of the new free-piston shock tunnel at GALCIT

The new free-piston shock tunnel has been partially calibrated, and a range of operating conditions has been found. A large number of difficulties were encountered during the shake-down period, of which the ablation of various parts was the most severe. Solutions to these problems were found. The general principles of high-enthalpy simulation are outlined, and the parameter space covered by T5 is given. Examples of the operating data show that, with care, excellent repeatability may be obtained. The temporal uniformity of the reservoir pressure is very good, even at high enthalpy, because it is possible to operate at tailored-interface and tuned-piston conditions over the whole enthalpy range. Examples of heat transfer and Pitot-pressure measurements are also presented.

Hornung, Hans G.

A combustion driven shock tunnel to complement the free piston shock tunnel T5 at GALCIT

A combustion driven shock tunnel was designed and built at GALCIT to supply the hypersonic facility T5 with 'hot' hydrogen for mixing and combustion experiments. This system was chosen over other options for better flexibility and for safety reasons. The shock tunnel is described and the overall efficiency of the system is discussed. The biggest challenge in the design was to synchronize the combustion driven shock tunnel with T5. To do so, the main diaphragm of the combustion driven shock tunnel is locally melted by an electrical discharge. This local melting is rapidly followed by the complete collapse of the diaphragm in a very repeatable way. A first set of experiments on supersonic hydrogen transverse jets over a flat plate have just been completed with the system and some of the preliminary results are presented.

Belanger, Jacques

Streamlining algorithms for complete adaptation

For purposes of the adaptive-wall algorithms to be described, the modern era is considered to have begun with the simultaneous, independent recognition of the concept of matching an experimental inner flow across an interface to a computed outer flow by Chevallier, Ferri, Goodyer, Lissaman, Rubbert, and Sears. Fundamental investigations of the adaptive-wall matching concept by means of numerical simulations and theoretical considerations are described. An overview of the development and operation of 2D adaptive-wall facilities from about 1970 until the present is given, followed by similar material for 3D adaptive-wall facilities from approximately 1978 until the present. A general formulation of adaptation strategy is presented, with a theoretical basis for adaptation followed by 2D flexible, impermeable-wall applications; 2D ventilated-wall applications; 3D flexible, impermeable-wall applications; and 3D ventilated-wall applications. Representative experimental and 3D results are given, with 2D, followed by a discussion of limitations and open questions.

Erickson, J. C., Jr.

Testing of 3-D models in 2-D adaptive wall test sections

Considerable effort was devoted to the development of two-dimensional adaptive wall test sections. The development of fully three-dimensional test sections, however, has not had this same level of effort expended. The limitations on three-dimensional research are the result of the complexity of both the mechanical design and operational aspects. Typical of the mechanical complexities are lack of readily available model and flow visualization access, and problems of sealing between adjacent walls for multi-wall types of test sections. The operational aspects are complicated by the necessity for many measurements of the boundary conditions which can be very time consuming. In three-dimensional testing, it is impossible to remove all of the boundary interference. It will be necessary, therefore, to apply residual corrections to the data. The more complex the test section shape, the more complex the calculation of the residual corrections becomes. From both the viewpoint of test section complexity and of ease of residual corrections, a simplified test section geometry is desirable. To aid in the design of simplified test sections, several researchers investigated the capability of using two-dimensional adaptive wall test sections to perform three-dimensional testing. By use of this type of design, the inherent complications and limitations of the fully three-dimensional design are avoided. Strategies of adaptation used for this application are described, as well as, sample results and a discussion of some limitations of the technique.

Wedemeyer, Erich H.