Inertial-confinement fusion-plasma-based cross-calibration of the deuterium-tritium γ-to-neutron branching ratio

The deuterium-tritium (D-T) γ -to-neutron branching ratio [ H 3 ( d , γ ) He 5 / H 3 ( d , n ) He 4 ] has been determined previously under inertial-confinement fusion (ICF) conditions and in beam-target based experiments. In the former case, neutron-induced backgrounds are mitigated compared to the latter due to the short pulse nature of ICF implosions and the use of gas Cherenkov γ -ray detectors. Furthermore, an added benefit of ICF based measurements is the ability to achieve lower center-of-mass energies as compared to accelerators. Previous ICF based experiments however report a large uncertainty in the D-T γ -to-neutron branching ratio of ≈ 48 % , which arises from the necessity of an absolute detector calibration and/or a cross-calibration against the D- He 3 γ -to-proton branching ratio. A more precise value for the branching ratio based on data taken at the OMEGA laser facility is reported here, which relies on a cross-calibration against the better known C 12 neutron inelastic scattering cross section. A D-T branching ratio value of ( 4.6 ± 0.6 ) × 10 - 5 is determined by this method.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First spectral measurement of deuterium-tritium fusion γ rays in inertial fusion experiments

Here, the R-matrix analysis of A = 5 nuclear systems has been partially validated by applying the technique to the 5 Li system and comparing the predicted γ-ray spectrum with historical data. R-matrix analysis of the similar 5 He system was then used to predict the γ-ray spectral shape for the deuterium-tritium (DT) reaction. The resulting spectra have been used in the analysis of DT implosions on the Omega laser where the γ-ray interaction rate was measured by a gas Cherenkov detector. Comparison of predictions to experiment confirmed the presence of both 16.75 and ≈ 13 MeV γ-ray contributions; analysis, using R-matrix spectra, yielded a ratio of γ-ray emission from a transition to the intermediate excited state to that from a transition to the ground state of (2.1 ± 0.4):1, substantiating the first spectral measurement of the DT fusion γ ray in an inertial fusion environment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Progress on next generation gamma-ray Cherenkov detectors for the National Ignition Facility

Fusion reaction history and ablator areal density measurements for Inertial Confinement Fusion experiments at the National Ignition Facility are currently conducted using the Gamma Reaction History diagnostic (GRH_6m). Future Gas Cherenkov Detectors (GCDs) will ultimately provide ~100x more sensitivity, reduce the effective temporal response from ~100 to ~10 ps, and lower the energy threshold from 2.9 to 1.8 MeV, relative to GRH_6m. The first phase toward next generation GCDs consisted of inserting the existing coaxial GCD-3 detector into a reentrant well which puts it within 4 m of the implosion. Reaction history and ablator gamma measurement results from this Phase I are discussed. These results demonstrate viability for the follow-on Phases of (II) the use of a revolutionary new pulse-dilation photomultiplier tube to improve the effective measurement bandwidth by >10x relative to current PMT technology; and (III) the design of a NIF-specific “Super” GCD which will be informed by the assessment of the radiation background environment within the well described here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pulse dilation gas Cherenkov detector for ultra-fast gamma reaction history at the National Ignition Facility (invited)

The Cherenkov mechanism used in Gas Cherenkov Detectors (GCDs) is exceptionally fast. However, the temporal resolution of GCDs, such as the Gamma Reaction History diagnostic at the National Ignition Facility (NIF), has been limited by the current state-of-the-art photomultiplier tube technology to ~100 ps. The soon-to-be deployed Pulse Dilation Photomultiplier Tube (PD-PMT) at NIF will allow for temporal resolution comparable to that of the gas cell or ~10 ps. Enhanced resolution will contribute to the quest for ignition in a crucial way through precision measurements of reaction history and ablator areal density (ρR) history, leading to better constrained models. Features such as onset of alpha heating, shock reverberations, and burn truncation due to dynamically evolving failure modes may become visible for the first time. Test measurements of the PD-PMT at Atomic Weapons Establishment confirmed that design goals have been met. The PD-PMT provides dilation factors of 2 to 40× in 6 increments. The GCD-3 recently deployed at the NIF has been modified for coupling to a PD-PMT and will soon be making ultrafast measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analogue saturation limit of single and double 10 mm microchannel plate photomultiplier tubes

Photek are a well-established supplier of microchannel plate (MCP) photomultiplier tubes (PMTs) to the inertial confinement fusion community. The analogue signals produced at the major inertial confinement fusion facilities cover many orders of magnitude, therefore understanding the upper saturation limit of MCP-PMTs to large low rate signals takes on a high importance. Here we present a study of a single and a double MCP-PMT with 10 mm diameter active area. The saturation was studied for a range of optical pulse widths from 4 ns to 100 ns and at a range of electron gain values: 10{sup 3} to 10{sup 4} for the single and 10{sup 4} to 10{sup 6} for the double. We have shown that the saturation level of ∼1.2 nC depends only on the integrated charge of the pulse and is independent of pulse width and gain over this range, but that the level of charge available in deep saturation is proportional to the operating gain.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Next Generation Gamma-Ray Cherenkov Detectors for the National Ignition Facility

The newest generation of Gas Cherenkov Detector (GCD-3) employed in Inertial Confinement Fusion experiments at the Omega Laser Facility has provided improved performance over previous generations. Comparison of reaction histories measured using two different deuterium-tritium fusion products, namely gamma rays using GCD and neutrons using Neutron Temporal Diagnostic (NTD), have provided added credibility to both techniques. GCD-3 is now being brought to the National Ignition Facility (NIF) to supplement the existing Gamma Reaction History (GRH-6m) located 6 m from target chamber center (TCC). Initially it will be located in a reentrant well located 3.9 m from TCC. Data from GCD-3 will inform the design of a heavily-shielded “Super” GCD to be located as close as 20 cm from TCC. In conclusion, it will also provide a test-bed for faster optical detectors, potentially lowering the temporal resolution from the current ~100 ps state-of-the-art photomultiplier tubes (PMT) to ~10 ps Pulse Dilation PMT technology currently under development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma ray measurements at OMEGA with the newest gas Cherenkov Detector “GCD-3”

Initial results from the newest Gas Cherenkov Detector (GCD-3) are reported demonstrating improved performance over previous GCD iterations. Increased shielding and lengthening of the Cherenkov photon optical path have resulted in a diminished precursor signal with increased temporal separation between the precursor and the primary DT Cherenkov signal. Design changes resulted in a measured GCD-3 sensitivity comparable to GCD-1 at identical 100 psia CO 2 operation. All metal gasket seals and pressure vessel certification to 400 psia operation allow for a GCD-3 lower Cherenkov threshold of 1.8 MeV using the fluorinated gas C 2 F 6 as compared to the 6.3 MeV lower limit of GCD-1 and GCD-2. Calibration data will be used to benchmark GEANT4 and ACCEPT detector models. Lastly, the GCD-3 acts as a prototype for the Super GCD being fielded at the National Ignition Facility (NIF) as part of the National Diagnostics Plan and will be installed at NIF in early 2016.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved time response for large area microchannel plate photomultiplier tubes in fusion diagnostics

Fusion diagnostics that utilise high speed scintillators often need to capture a large area of light with a high degree of time accuracy. Microchannel plate (MCP) photomultiplier tubes (PMTs) are recognised as the leading device for capturing fast optical signals. However, when manufactured in their traditional proximity focused construction, the time response performance is reduced as the active area increases. This is due to two main factors: the capacitance of a large anode and the difficulty of obtaining small pore MCPs with a large area. Collaboration between Photek and AWE has produced prototype devices that combine the excellent time response of small area MCP-PMTs with a large active area by replacing the traditional proximity-gap front section with an electro-optically focused photocathode to MCP. We present results from both single and double MCP devices with a 40 mm diameter active area and show simulations for the 100 mm device being built this year.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extended performance gas Cherenkov detector for gamma-ray detection in high-energy density experiments

A new Gas Cherenkov Detector (GCD) with low-energy threshold and high sensitivity, currently known as Super GCD (or GCD-3 at OMEGA), is being developed for use at the OMEGA Laser Facility and the National Ignition Facility (NIF). Super GCD is designed to be pressurized to ≤400 psi (absolute) and uses all metal seals to allow the use of fluorinated gases inside the target chamber. This will allow the gamma energy threshold to be run as low at 1.8 MeV with 400 psi (absolute) of C{sub 2}F{sub 6}, opening up a new portion of the gamma ray spectrum. Super GCD operating at 20 cm from TCC will be ∼400 × more efficient at detecting DT fusion gammas at 16.7 MeV than the Gamma Reaction History diagnostic at NIF (GRH-6m) when operated at their minimum thresholds.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo validation experiments for the gas Cherenkov detectors at the National Ignition Facility and Omega

The gas Cherenkov detectors at NIF and Omega measure several ICF burn characteristics by detecting multi-MeV nuclear γ emissions from the implosion. Of primary interest are γ bang-time (GBT) and burn width defined as the time between initial laser-plasma interaction and peak in the fusion reaction history and the FWHM of the reaction history respectively. To accurately calculate such parameters the collaboration relies on Monte Carlo codes, such as GEANT4 and ACCEPT, for diagnostic properties that cannot be measured directly. This paper describes a series of experiments performed at the High Intensity γ Source (HIγS) facility at Duke University to validate the geometries and material data used in the Monte Carlo simulations. Results published here show that model-driven parameters such as intensity and temporal response can be used with less than 50% uncertainty for all diagnostics and facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of areal density in the ablators of inertial-confinement-fusion capsules via detection of ablator (n, n Prime {gamma}) gamma-ray emission

We report the first gamma-ray-based measurements of the areal density of ablators in inertial-confinement-fusion capsule implosions. The measurements, made at the OMEGA laser [T. R. Boehly et al., Opt. Commun. 133, 495 (1997)], used observations of gamma rays arising from inelastic scattering of 14.1-MeV deuterium-tritium (DT) neutrons on {sup 12}C nuclei in the compressed plastic ablators. The emission of {sup 12}C(n,n Prime {gamma}) gamma rays from the capsules is detected using the Gamma Reaction History instrument [H. W. Herrmann et al., J. Phys.: Conf. Ser. 244, 032047 (2010)] operating at OMEGA. From the ratio of a capsule's {sup 12}C(n,n Prime {gamma}) emission to the emission from the same processes in an in situ reference graphite 'puck' of known mass and geometry [N. M. Hoffman et al., in IFSA 2011 proceedings (submitted)], we determine the time-averaged areal density of {sup 12}C in the capsule's compressed ablator. Measured values of total ablator areal density for thirteen imploded capsules, in the range 23 {+-} 10 to 58 {+-} 14 mg/cm{sup 2}, are comparable to values calculated in 1D radiation-hydrodynamic simulations, and measured by charged-particle techniques.

36 MATERIALS SCIENCE↗

Ultra-high speed photomultiplier tubes with nanosecond gating for fusion diagnostics

Fusion diagnostics can involve the measurement of ultra-fast optical pulses, often in close temporal proximity. We present a solution for the diagnostics of gamma reaction history and neutron time of flight by using microchannel plate based photomultiplier tubes (PMTs). The time response of the PMTs can be as fast as 100 ps FWHM and with a gain of up to 10{sup 7}. To observe small events in close temporal proximity to much larger signals such as the down-scattered fraction, the response of MCP-PMTs can be gated with an on/off ratio of up to 10{sup 13} in just 2 ns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ORION laser target diagnostics

The ORION laser facility is one of the UK's premier laser facilities which became operational at AWE in 2010. Its primary mission is one of stockpile stewardship, ORION will extend the UK's experimental plasma physics capability to the high temperature, high density regime relevant to Atomic Weapons Establishment's (AWE) program. The ORION laser combines ten laser beams operating in the ns regime with two sub ps short pulse chirped pulse amplification beams. This gives the UK a unique combined long pulse/short pulse laser capability which is not only available to AWE personnel but also gives access to our international partners and visiting UK academia. The ORION laser facility is equipped with a comprehensive suite of some 45 diagnostics covering optical, particle, and x-ray diagnostics all able to image the laser target interaction point. This paper focuses on a small selection of these diagnostics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗