What are the energy and greenhouse gas benefits of repurposing non-residential buildings into apartments?
Not Available
Engineering topics
Publications and source records attributed to Horvath, Arpad.
Not Available
Not Available
In today’s LCA world, one can encounter a variety of LCA practitioners and commissioners from different industries and fields of research who have different levels of expertise, experience, and expectations. Even those with more experience who are actively involved in the field of LCA can have rather varying opinions about what ISO 14044 requires (or does not require) regarding the preparation, critical review, and dissemination of third-party reports in accordance with ISO 14044:2006, clauses 5 and 6 (ISO 2006a).
This paper, which is a contribution to the UNEP series on Eco-Efficient Cements, examines the role of material-based solutions to reducing CO{sub 2} emissions from cement production considering factors that could influence implementation. Global urbanization has led to an increase in demand for cement and cement-based materials. With its growth in consumption, the associated CO{sub 2} emissions from its production are raising concern. However, the role of mitigation strategies in a global context that account for regional material availability and degree of market adoption have yet to be considered. This work shows that the 2 °C scenario targets for 2050 can be met through increased use of calcined clay and engineered filler with dispersants. The introduction of new Portland clinker-based cement alternatives, use of alkali-activated materials, and improvement of efficiency of cement use could further contribute to reduction goals. There are currently-available technologies for reduction that could be rapidly implemented.
Not Available
Not Available
Explore the source record for details and available documents.
The 2006 California Global Warming Solutions Act calls for reducing greenhouse gas (GHG) emissions to 1990 levels by 2020. Meeting this target will require action from all sectors of the California economy, including industry. The industrial sector consumes 25% of the energy used and emits 28% of the carbon dioxide (CO{sub 2}) produced in the state. Many countries around the world have national-level GHG reduction or energy-efficiency targets, and comprehensive programs focused on implementation of energy efficiency and GHG emissions mitigation measures in the industrial sector are essential for achieving their goals. A combination of targets and industry-focused supporting programs has led to significant investments in energy efficiency as well as reductions in GHG emissions within the industrial sectors in these countries. This project has identified program and policies that have effectively targeted the industrial sector in other countries to achieve real energy and CO{sub 2} savings. Programs in Ireland, France, The Netherlands, Denmark, and the UK were chosen for detailed review. Based on the international experience documented in this report, it is recommended that companies in California's industrial sector be engaged in a program to provide them with support to meet the requirements of AB32, The Global Warming Solution Act. As shown in this review, structured programs that engage industry, require members to evaluate their potential efficiency measures, plan how to meet efficiency or emissions reduction goals, and provide support in achieving the goals, can be quite effective at assisting companies to achieve energy efficiency levels beyond those that can be expected to be achieved autonomously.
This report provides a critical review of existing literature and modeling tools related to life-cycle assessment (LCA) applied to pavements. The review finds that pavement LCA is an expanding but still limited research topic in the literature, and that the existing body of work exhibits methodological deficiencies and incompatibilities that serve as barriers to the widespread utilization of LCA by pavement engineers and policy makers. This review identifies five key issues in the current body of work: inconsistent functional units, improper system boundaries, imbalanced data for asphalt and cement, use of limited inventory and impact assessment categories, and poor overall utility. This review also identifies common data and modeling gaps in pavement LCAs that should be addressed in future work. These gaps include: the use phase (rolling resistance, albedo, carbonation, lighting, leachate, and tire wear and emissions), asphalt fumes, feedstock energy of bitumen, traffic delay, the maintenance phase, and the end-of-life phase. This review concludes with a comprehensive list of recommendations for future research, which shed light on where improvements in knowledge can be made that will benefit the accuracy and comprehensiveness of pavement LCAs moving forward.
Explore the source record for details and available documents.
Economizer use in data centers is an energy efficiency strategy that could significantly limit electricity demand in this rapidly growing economic sector. Widespread economizer implementation, however, has been hindered by potential equipment reliability concerns associated with exposing information technology equipment to particulate matter of outdoor origin. This study explores the feasibility of using economizers in data centers to save energy while controlling particle concentrations with high-quality air filtration. Physical and chemical properties of indoor and outdoor particles were analyzed at an operating northern California data center equipped with an economizer under varying levels of air filtration efficiency. Results show that when improved filtration is used in combination with an economizer, the indoor/outdoor concentration ratios for most measured particle types were similar to levels when using conventional filtration without economizers. An energy analysis of the data center reveals that, even during the summer months, chiller savings from economizer use greatly outweigh any increase in fan power associated with improved filtration. These findings indicate that economizer use combined with improved filtration could reduce data center energy demand while providing a level of protection from particles of outdoor origin similar to that observed with conventional design.