The DAMIC-M experiment: Status and first results

The DAMIC-M (DArk Matter In CCDs at Modane) experiment employs thick, fully depleted silicon charged-coupled devices (CCDs) to search for dark matter particles with a target exposure of 1 kg-year. A novel skipper readout implemented in the CCDs provides single electron resolution through multiple non-destructive measurements of the individual pixel charge, pushing the detection threshold to the eV-scale. DAMIC-M will advance by several orders of magnitude the exploration of the dark matter particle hypothesis, in particular of candidates pertaining to the so-called “hidden sector.” A prototype, the Low Background Chamber (LBC), with 20g of low background Skipper CCDs, has been recently installed at Laboratoire Souterrain de Modane and is currently taking data. We will report the status of the DAMIC-M experiment and first results obtained with LBC commissioning data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of Marine Borne Radioactive Sources Report

This report describes a preliminary analysis on the utility of modern capabilities to localize radiological sources in marine environment. This study analyzed expected background sources and identified possible approaches based on modeling and simulation analyses. The effort culminated in the design and fabrication of validation experiments which provided favorable supporting data. The conclusions of this effort are not conclusive as to the viability of the approach nor is the underlining hypothesis discounted. Continuation of the experimental approach is recommended with a focus on open-water experimentation.

54 ENVIRONMENTAL SCIENCES↗

Highly Segmented Silicon Strip Detectors for Radiation Detection (LDRD Final Report)

Large area highly segmented silicon strip detectors were investigated for use in applied radiation detection applications. Two ASIC-based readout electronics solutions were tested for compatibility. During the analysis, it was determined that significant computational resources and highly specialized firmware are required to reconstruct the data into a meaningful data stream for generalized spectroscopic performance. Future investment in the technology and careful choice of readout ASIC is expected to demonstrate relevance in measuring high activity samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results on low-mass weakly interacting massive particles from an 11 kg d target exposure of DAMIC at SNOLAB

We present constraints on the existence of weakly interacting massive particles (WIMPs) from a 11 kg-day target exposure of the DAMIC experiment at the SNOLAB underground laboratory. The observed energy spectrum and spatial distribution of ionization events with electron-equivalent energies $>$200 eV$_{\rm ee}$ in the DAMIC CCDs are consistent with backgrounds from natural radioactivity. An excess of ionization events is observed above the analysis threshold of 50 eV$_{\rm ee}$. While the origin of this low-energy excess requires further investigation, our data exclude spin-independent WIMP-nucleon scattering cross sections $\sigma_{\chi-n}$ as low as $3\times 10^{-41}$ cm$^2$ for WIMPs with masses $m_{\chi}$ from 7 to 10 GeV$c^{-2}$ . These results are the strongest constraints from a silicon target on the existence of WIMPs with $m_{\chi}$$<$9 GeV$c^{-2}$ and are directly relevant to any dark matter interpretation of the excess of nuclear-recoil events observed by the CDMS silicon experiment in 2013.

WIMP search, Dark Matter, DAMIC, SNOLAB↗

High Throughput Argon-37 Field System

We report Pacific Northwest National Laboratory (PNNL) has developed a unique fieldable 37 Ar measurement system designed to measure 37 Ar activity concentrations from soil gas samples to detect above ground and underground nuclear explosions. The Argon-37 Field System is modular in design to accommodate both chemical processing and nuclear detection. The system can be packed into shipping crates and shipped to a location near where the sampling is taking place. The system can process six 2-m 3 whole-air samples in 24 hours and can measure the 37 Ar activity in each of the samples using six proportional counters. The proportional counters, designed and built at PNNL, are surrounded with both active and passive shielding to reduce background and can achieve a minimum detection concentration of 10 mBq/m 3 of 37 Ar in whole-air equivalent. The Argon-37 Field System has undergone extensive testing against rigorous requirements to assure the system meets the needs of the noble gas nuclear explosion monitoring community.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Constraints on Light Dark Matter Particles Interacting with Electrons from DAMIC at SNOLAB

We report direct-detection constraints on light dark matter particles interacting with electrons. The results are based on a method that exploits the extremely low levels of leakage current of the DAMIC detector at SNOLAB of 2–6×10-22 A cm^-2. We evaluate the charge distribution of pixels that collect < 10 e- for contributions beyond the leakage current that may be attributed to dark matter interactions. Constraints are placed on so-far unexplored parameter space for dark matter masses between 0.6 and 100 MeV c^-2. We also present new constraints on hidden-photon dark matter with masses in the range 1.2–30 eV c^-2.

Dark Matter, DAMIC, SNOLAB↗

Search for Neutrinoless Double-ß Decay in 76Ge with the Majorana Demonstrator

The Majorana Collaboration is operating an array of high purity Ge detectors to search for neutrinoless double-beta decay in 76Ge. The Majorana Demonstrator is comprised of 44.8 kg (29.7 kg enriched in 76Ge) of Ge detectors in total, split between two modules contained in a low background shield at the Sanford Underground Research Facility in Lead, South Dakota. Here we present results from data taken during construction, commissioning, and the start of full operations. Given the unprecedented energy resolution at Q of 2.5 keV FWHM and the very low background with no observed candidate events in 10 kg yr of enriched Ge exposure, we find a lower limit on the half-life of 1:9 x 1025 yr (90% CL). This result constrains the effective Majorana neutrino mass to below 250 to 550 meV, depending on the matrix elements used. In our experimental configuration with the lowest background, the background is 4:0 +3:1(superscript) -2:5 (subscript) counts/(FWHM t yr) at 68% CL.

Aalseth, Craig E.↗

A Low-Noise Germanium Ionization Spectrometer for Low-Background Science

Recent progress on the development of very low energy threshold high purity germanium ionization spectrometers has produced an instrument of 1.2 kg mass and excellent noise performance. The detector was installed in a low-background cryostat intended for use in a low mass, WIMP dark matter direct detection search. The integrated detector and low background cryostat achieved noise performance of 98 eV full-width half-maximum of an input electronic pulse generator peak and gamma-ray energy resolution of 1.9 keV full-width half-maximum at the 60Co gamma-ray energy of 1332 keV. This Transaction reports the thermal characterization of the low-background cryostat, specifications of the newly prepared 1.2 kg p-type point contact germanium detector, and the ionization spectroscopy – energy resolution and energy threshold – performance of the integrated system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement Background and the Sediment Age-Dating Reach of 32Si

Silicon-32 has been identified as an isotope that fills the sediment geochronology gap created between Pb-210 at <150 years and C-14 at >1000 years. However, detector sensitivity and chemical isolation challenges of radiometric Si-32 for age dating have resulted in a fairly limited number of applications of this technique to real-world sediment studies. The significance of targeting the intermediate age bracket is to provide accurate geochronological reconstructions of paleoindicators that identify human and large-scale, climate-induced shifts in coastal areas. Therefore, we targeted Puget Sound, Washington, United States, to demonstrate the application of Si-32 age dating to determine the relative importance of climate cycles versus human activities in an in-land sea. The enhanced reconstructions will be achieved through the design of new detectors, chemical separation of biogenic silica from kilogram-scale sediment samples, and demonstration of the viable age-dating reach of Si-32. Implications of detector background on the duration of required measurements and the age-dating reach are considered. The design of a low-background, gas-proportional beta counter for measurement of the daughter isotope P-32 is discussed; detector background goals for these new detectors are based on the sensitivity study.

Keillor, Martin E.↗

A Segmented, Enriched N-type Germanium Detector for Neutrinoless Double Beta-Decay Experiments

We present data characterizing the performance of the _rst segmented, N- type Ge detector, isotopically enriched to 85% 76Ge. This detector, based on the Ortec PT6x2 design and referred to as SEGA (Segmented, Enriched Germanium Assembly), was developed as a possible prototype for neutrinoless double beta-decay measurements by the Majorana collaboration. We present some of the general characteristics (including bias potential, efficiency, leakage current, and integral cross-talk) for this detector in its temporary cryostat. We also present an analysis of the resolution of the detector, and demonstrate that for all but two segments there is at least one channel that reaches the Majorana resolution goal below 4 keV FWHM at 2039 keV, and all channels are below 4.5 keV FWHM.

detector↗

CoGeNT: A Search for Low-Mass Dark Matter using p-type Point Contact Germanium Detectors

CoGeNT employs p-type point-contact (PPC) germanium detectors to search for Weakly In- teracting Massive Particles (WIMPs). By virtue of its low energy threshold and ability to reject surface backgrounds, this type of device allows an emphasis on low-mass dark matter candidates (m* * 10 GeV/c2). We report on the characteristics of the PPC detector presently taking data at the Soudan Underground Laboratory, elaborating on aspects of shielding, data acquisition, instru- mental stability, data analysis, and background estimation. A detailed background model is used to investigate the low energy excess of events previously reported, and to assess the possibility of temporal modulations in the low-energy event rate. We conclude that the technique is ideally suited to search for the annual modulation signature expected from dark matter particle interactions in the region of WIMP mass and coupling favored by the DAMA/LIBRA claim.

Aalseth, Craig E.↗

Empirical Correction of Crosstalk in a Low-Background Germanium γ–γ Analysis System

ABSTRACT The Pacific Northwest National Laboratory is currently developing a custom software suite capable of automating many of the tasks required to accurately analyze coincident signals within gamma spectrometer arrays. During the course of this work, significant crosstalk was identified in the energy determination for spectra collected with a new low-background intrinsic germanium (HPGe) array at PNNL. The HPGe array is designed for high detection efficiency, ultra-low-background performance, and sensitive gamma gamma coincidence detection. The first half of the array, a single cryostat containing 7 HPGe crystals, was recently installed into a new shallow underground laboratory facility. This update will present a brief review of the germanium array, describe the observed crosstalk, and present a straight-forward empirical correction that significantly reduces the impact of this crosstalk on the spectroscopic performance of the system.

coincidence↗

Determining HPGe Total Detection Efficiency Using γ–γ Coincidence

Abstract Both the peak and total detection efficiencies are generally needed in order to calculate sample activity from a gamma spectroscopic measurement, except in the case of isotope specific calibration. This is particularly true when the sample is in close proximity to the detector and corrections for cascade summing effects are required to avoid significant inaccuracy in the result. These corrections use the total detection efficiency to correct for summing-in and summing-out events, and the extent of the correction depends on both the geometry and the gamma cascade for the isotope in question. Experimentally determining the total efficiency is a labor intensive endeavor requiring multiple measurements with a set of single-gamma-emitting standards. Modeling the total efficiency vs. energy may be less time consuming, but is also likely to produce less confidence in the final result. Pacific Northwest National Laboratory's Radiation Detection and Nuclear Sciences group has constructed a low background 14-crystal HPGe array for sample measurement; in all measurements, samples will be in close proximity to the germanium crystals. This close geometry and the sheer number efficiency calibrations required for the system have led us to investigate methods to simplify the efficiency calibration procedure. One method we are developing uses the Y-Y coincidence plane to isolate Compton scattering event populations, allowing experimental determination of total detection efficiency values from the measurement of a single mixed isotope standard. A description of the analysis and experimental results of this method are presented.

low background HPGe High Purity Germanium detector↗

Cryostat for Ultra-low-energy Threshold Germanium Spectrometers

This paper presents progress on the development of a cryostat intended to improve upon the low-energy threshold (below 0.5 keV) of p-type point contact germanium gamma-ray spectrometers. Ultra-low energy thresholds are important in the detection of low-energy nuclear recoils, an event class relevant to both dark matter direct detection and measurement of coherent neutrino-nucleus scattering. The cryostat design, including a thermal and electrical-field model, is presented. A prototype cryostat has been assembled and data acquired to evaluate its vacuum and thermal performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The C-4 Dark Matter Experiment

Abstract We describe the experimental design of C-4, an expansion of the CoGeNT dark matter search to four identical detectors each approximately three times the mass of the p-type point contact (PPC) germanium diode presently taking data at the Soudan Underground Laboratory. Expected reductions of radioactive backgrounds and energy threshold are discussed, including an estimate of the additional sensitivity to low-mass dark matter candidates to be obtained with this search.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Multi-sensor Airborne Radiation Survey (MARS) Instrument

The Multi-sensor Airborne Radiation Survey (MARS) project has developed a new single cryostat detector array design for high purity germanium (HPGe) gama ray spectrometers that achieves the high detection efficiency required for stand-off detection and actionable characterization of radiological threats. This approach, we found, is necessary since a high efficiency HPGe detector can only be built as an array due to limitations in growing large germanium crystals. Moreover, the system is ruggedized and shock mounted for use in a variety of field applications, including airborne and maritime operations.

array↗

A Germanium Array for Sample Measurements: Recent Results and New Analysis Methods

ABSTRACT The Pacific Northwest National Laboratory is finalizing construction of a 14-crystal intrinsic germanium (HPGe) array designed for high detection efficiency, ultra-low-background performance, and sensitive gamma gamma coincidence detection. Initial development of a custom software suite capable of automating many of the tasks required to accurately analyze coincident signals within close-geometry detector arrays will also be completed this year. The analysis capability is required to enable rapid interpretation of data collected with the low-background (HPGe) array. The status of final construction of the 2nd cryostat and the complete system will be discussed, as well as measurement results from independent operation of the 1st cryostat. Status of the CASCADES analysis development, including cross-talk correction and new techniques for efficiency calibration, are also presented.