Search NASA⌕ Search

Engineering topics

Hossbach, Todd W.

Publications and source records attributed to Hossbach, Todd W..

The DAMIC-M experiment: Status and first results

The DAMIC-M (DArk Matter In CCDs at Modane) experiment employs thick, fully depleted silicon charged-coupled devices (CCDs) to search for dark matter particles with a target exposure of 1 kg-year. A novel skipper readout implemented in the CCDs provides single electron resolution through multiple non-destructive measurements of the individual pixel charge, pushing the detection threshold to the eV-scale. DAMIC-M will advance by several orders of magnitude the exploration of the dark matter particle hypothesis, in particular of candidates pertaining to the so-called “hidden sector.” A prototype, the Low Background Chamber (LBC), with 20g of low background Skipper CCDs, has been recently installed at Laboratoire Souterrain de Modane and is currently taking data. We will report the status of the DAMIC-M experiment and first results obtained with LBC commissioning data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of Marine Borne Radioactive Sources Report

This report describes a preliminary analysis on the utility of modern capabilities to localize radiological sources in marine environment. This study analyzed expected background sources and identified possible approaches based on modeling and simulation analyses. The effort culminated in the design and fabrication of validation experiments which provided favorable supporting data. The conclusions of this effort are not conclusive as to the viability of the approach nor is the underlining hypothesis discounted. Continuation of the experimental approach is recommended with a focus on open-water experimentation.

54 ENVIRONMENTAL SCIENCES↗

Highly Segmented Silicon Strip Detectors for Radiation Detection (LDRD Final Report)

Large area highly segmented silicon strip detectors were investigated for use in applied radiation detection applications. Two ASIC-based readout electronics solutions were tested for compatibility. During the analysis, it was determined that significant computational resources and highly specialized firmware are required to reconstruct the data into a meaningful data stream for generalized spectroscopic performance. Future investment in the technology and careful choice of readout ASIC is expected to demonstrate relevance in measuring high activity samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results on low-mass weakly interacting massive particles from an 11 kg d target exposure of DAMIC at SNOLAB

We present constraints on the existence of weakly interacting massive particles (WIMPs) from a 11 kg-day target exposure of the DAMIC experiment at the SNOLAB underground laboratory. The observed energy spectrum and spatial distribution of ionization events with electron-equivalent energies $>$200 eV$_{\rm ee}$ in the DAMIC CCDs are consistent with backgrounds from natural radioactivity. An excess of ionization events is observed above the analysis threshold of 50 eV$_{\rm ee}$. While the origin of this low-energy excess requires further investigation, our data exclude spin-independent WIMP-nucleon scattering cross sections $\sigma_{\chi-n}$ as low as $3\times 10^{-41}$ cm$^2$ for WIMPs with masses $m_{\chi}$ from 7 to 10 GeV$c^{-2}$ . These results are the strongest constraints from a silicon target on the existence of WIMPs with $m_{\chi}$$<$9 GeV$c^{-2}$ and are directly relevant to any dark matter interpretation of the excess of nuclear-recoil events observed by the CDMS silicon experiment in 2013.

WIMP search, Dark Matter, DAMIC, SNOLAB↗

High Throughput Argon-37 Field System

We report Pacific Northwest National Laboratory (PNNL) has developed a unique fieldable 37 Ar measurement system designed to measure 37 Ar activity concentrations from soil gas samples to detect above ground and underground nuclear explosions. The Argon-37 Field System is modular in design to accommodate both chemical processing and nuclear detection. The system can be packed into shipping crates and shipped to a location near where the sampling is taking place. The system can process six 2-m 3 whole-air samples in 24 hours and can measure the 37 Ar activity in each of the samples using six proportional counters. The proportional counters, designed and built at PNNL, are surrounded with both active and passive shielding to reduce background and can achieve a minimum detection concentration of 10 mBq/m 3 of 37 Ar in whole-air equivalent. The Argon-37 Field System has undergone extensive testing against rigorous requirements to assure the system meets the needs of the noble gas nuclear explosion monitoring community.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗