Search NASA⌕ Search

Engineering topics

Hoteling, N J

Publications and source records attributed to Hoteling, N J.

An analytical model for pulse shape and electrothermal stability in two-body transition-edge sensor microcalorimeters

High-resolution superconducting gamma-ray sensors show potential for the more accurate analysis of nuclear material. These devices are part of a larger class of microcalorimeters and bolometers based on transition edge sensors (TESs) that have two distinct thermal bodies. We derive the time domain behavior of the current and temperature for compound TES devices in the small signal limit and demonstrate the utility of these equations for device design and characterization. In particular, we use the model to fit pulses from our gamma-ray microcalorimeters and demonstrate how critical damping and electrothermal stability can be predicted.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using exotic atoms to keep borders safe

Muons, created by a particle accelerator, can be used to scan cargo for special nuclear materials (SNM). These muons exist long enough and are penetrating enough that they can be used to actively scan cargo to ensure the non-proliferation of SNM. A set of 'proof-of-concept' experiments have been performed to show that active muon analysis can be used. Experiments were performed at high intensity, medium energy particle accelerators (TRIUMF and PSI). Negative muons form exotic atoms with one electron replaced by the muon. Since the muon is captured in an excited state, it will give off x-rays which can be detected by high purity germanium detectors. These characteristic x-rays can be used to identify the nuclide. The muonic x-rays corresponding to the SNM of interest have been measured, even with the use of various shielding configurations composed of lead, iron, polyethylene, or fiberglass. These preliminary results show that muons can be successfully used to find shielded SNM. The safety of North Americans can be protected by the use of this technology.

43 PARTICLE ACCELERATORS↗

Cryogenic microcalorimeter system for ultra-high resolution alpha-particle spectrometry

Microcalorimeters have been shown to yield unsurpassed energy resolution for alpha spectrometry, up to 1.06 keV FWHM at 5.3 MeV. These detectors use a superconducting transition-edge sensor (TES) to measure the temperature change in an absorber from energy deposited by an interacting alpha particle. Our system has four independent detectors mounted inside a liquid nitrogen/liquid helium cryostat. An adiabatic demagnetization refrigerator (ADR) cools the detector stage to its operating temperature of 80 mK. Temperature regulation with {approx}15 uK peak-to-peak variation is achieved by PID control of the ADR. The detectors are voltage-biased, and the current signal is amplified by a commercial SQUID readout system and digitized for further analysis, This paper will discuss design and operation of our microcalorimeter alpha spectrometer, and will show recent results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗