Search NASA⌕ Search

Engineering topics

Hou, Yunhe

Publications and source records attributed to Hou, Yunhe.

A Distributionally Robust Resilience Enhancement Strategy for Distribution Networks Considering Decision-Dependent Contingencies

When performing the resilience enhancement for distribution networks, there are two obstacles to reliably model the uncertain contingencies: 1) decision-dependent uncertainty (DDU) due to various line hardening decisions, and 2) distributional ambiguity due to limited outage information during extreme weather events (EWEs). Here, to address these two challenges, this paper develops scenario-wise decision-dependent ambiguity sets (SWDD-ASs), where the DDU and distributional ambiguity inherent in EWE-induced contingencies are simultaneously captured for each possible EWE scenario. Then, a two-stage tri-level decision-dependent distributionally robust resilient enhancement (DD-DRRE) model is formulated, whose outputs include the optimal line hardening, distributed generation (DG) allocation, and proactive network reconfiguration strategy under the worst-case distributions in SWDD-ASs. Subsequently, the DD-DRRE model is equivalently recast to a mixed-integer linear programming (MILP)-based master problem and multiple scenario-wise subproblems, facilitating the adoption of a customized column-and-constraint generation (C&CG) algorithm. Finally, case studies demonstrate a remarkable improvement in the out-of-sample performance of our model, compared to its prevailing stochastic and robust counterparts. Moreover, the potential values of incorporating the ambiguity and distributional information are quantitatively estimated, providing a useful reference for planners with different budgets and risk-aversion levels.

decision-dependent uncertainty↗

Small-Signal Angle Stability-Oriented False Data Injection Cyber-Attacks on Power Systems

The small-signal angle stability (SSAS) of a power system is determined by the property of operation points. The widely applied false data injection (FDI) cyber-attack, however, is able to stealthily mislead the optimal power flow (OPF) and thus compromise operation points, leading to damages to the SSAS margin. Here, to provide insights for cyber defenders, this paper proposes and investigates a stealthy SSAS-oriented FDI cyber-attack focusing on two attacking purposes, i.e., the SSAS margin and operation cost, with higher priority on the former one. First, this paper establishes a novel bi-level model with an implicit SSAS constraint based on a structure preserving model to compromise operation points. Then, for the SSAS interarea mode in a typical two-area system, this paper formulates closed-form expressions of how the SSAS margin and operation cost behave with respect to stealthy injections. By comparison, for the SSAS local mode in general power systems, this paper proposes a moving target cyber-attack-based hierarchical solution algorithm. Simulation results on a two-area system, a Kundur 11 bus system, and a modified IEEE 14 bus system demonstrate the significant damaging effects of the proposed SSAS-oriented FDI cyber-attack and the conflict between the two attacking purposes.

Benders decomposition↗

The Cost and Benefit of Enhancing Cybersecurity for Hybrid AC/DC Grids

As critical interfaces of AC grids and DC grids inside a hybrid AC/DC grid, the voltage-sourced-converter (VSC) has been demonstrated to be vulnerable to false data injection (FDI) cyber-attacks. As a result, the cyber-attack-induced AC grid frequency deviations and DC grid voltage deviations threaten the secure operation. Here, to enhance cybersecurity in a not only feasible but also cost-effective manner, this paper proposes a cost-benefit-based cyber-defense strategy for a hybrid AC/DC grid. First, this paper establishes a spatial-temporal dual cyber-attack evaluation model, in which the cyber-attack-induced frequency and voltage deviations are modelled in both a spatially and temporally dual manner. Then, the proposed cost-benefit-based cyber-defense strategy is modelled as a VSC commitment problem to achieve the trade-off between maximizing the cyber-defense benefits and minimizing the cyber-defense costs. The VSC commitment problem is then mathematically convexified into a mixed-integer second-order cone programming (MISOCP) problem, which could be efficiently solved in an event-triggered manner against unfolding cyber-attack events. Simulation results on a test hybrid AC/DC grid verified the feasibility and the cost-effectiveness of the proposed cyber-defense strategy.

cost-benefit analysis↗

Cybersecurity Enhancement for Multi-Infeed High-Voltage DC Systems

Composed of multiple two-terminal high-voltage DC (HVDC) transmission systems, a multi-infeed HVDC (MIDC) system exchanges massive power among multiple asynchronous AC systems. However, as an intrinsically cyber-physical system, an MIDC system could suffer from cyber-attacks, leading to massive power mismatches in multiple AC systems, and resulting in catastrophic consequences. Since the sequential responses of an MIDC system and interconnected AC systems are in different timescales, this paper first establishes a two-timescale model to evaluate the sequential impacts caused by cyber-attacks. Then, an event-triggered cyber-defense strategy is proposed to enhance the cybersecurity of an MIDC system by mitigating multiple non-simultaneous cyber-attacks. Whenever new cyber-attack events occur, the proposed cyber-defense strategy, which is mathematically modeled as a mixed-integer quadratic programming problem, is executed on-line and updated in an event-triggered manner. Here, simulation results on an MIDC system demonstrate that the low-cost and almost blind cyber-attacks can cause severe frequency deviations, and the proposed strategy can mitigate multi-cyber-attacks effectively.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Restoration Strategy for Active Distribution Systems Considering Endogenous Uncertainty in Cold Load Pickup

Cold load pickup (CLPU) phenomenon is identified as the persistent power inrush upon a sudden load pickup after an outage. Under the active distribution system (ADS) paradigm, where distributed energy resources (DERs) are extensively installed, the decreased outage duration can induce a strong interdependence between CLPU pattern and load pickup decisions. In this paper, we propose a novel modelling technique to tractably capture the decision-dependent uncertainty (DDU) inherent in the CLPU process. Subsequently, a two-stage stochastic decision-dependent service restoration (SDDSR) model is constructed, where first stage searches for the optimal switching sequences to decide step-wise network topology, and the second stage optimizes the detailed generation schedule of DERs as well as the energization of switchable loads. Further, to tackle the computational burdens introduced by mixed-integer recourse, the progressive hedging algorithm (PHA) is utilized to decompose the original model into scenario-wise subproblems that can be solved in parallel. The numerical test on modified IEEE 123-node test feeders has verified the efficiency of our proposed SDDSR model and provided fresh insights into the monetary and secure values of DDU quantification.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Extended convex hull-based distributed optimal energy flow of integrated electricity-gas systems

Integrated electricity and gas systems are constructed to facilitate the gas-fired generation, and the distributed operation of these integrated systems have received much attention due to the increased emphasis on data security and privacy between different agencies. This paper proposes an extended convex hull based method to address optimal energy flow problems for the integrated electricity and gas systems in a distributed manner. First, a multi-block electricity-gas system model is constructed by dividing the whole system into N blocks considering both physical and regional differences. This multi-block model is then convexified by replacing the nonconvex gas transmission equation with the extended convex hull-based constraints. The Jacobi-Proximal alternating direction method of multipliers algorithm is adopted to solve the convexified model and minimize its operation cost. Finally, the feasibility of the optimal solution for the convexified model is checked, and a sufficient condition is developed. If the sufficient condition is satisfied, the optimal solution for the original nonconvex problem can be recovered from that for the convexified problem. Simulation results demonstrate that the proposed method is tractable and effective in obtaining feasible optimal solutions for multi-block optimal energy flow problems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data-Based Resilience Enhancement Strategies for Electric-Gas Systems Against Sequential Extreme Weather Events

Some extreme weather events, such as the hurricane, pass through an area sequentially and thus are called sequential extreme weather events (SEWEs). This paper proposes a data-based robust optimization (RO) model to enhance the resilience of the integrated electricity and gas system (IEGS) against SEWEs. Specifically, the SEWE strikes the IEGS sequentially. After each attack, the system state is adjusted immediately to minimize the maximized expected system cost caused by the SEWE. The attack-defense procedures are repeated alternatively during the SEWE. Preventive measures, hardening, are made in advance to reduce the impact of sequential attacks. The entire process is formulated as a multi-period RO model. Furthermore, it is proved that the most effective resilience enhancement strategies for this model are the same as those for a two-stage RO model, which can be solved by the nested column-and-constraint generation (C&CG) algorithm. In addition, the property of SEWEs, sequentially endangering limited regions of the IEGS, is incorporated to build a data-based uncertainty set and reduce its conservativeness. Simulation results on two IEGSs validate the effectiveness of the proposed model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Resilient Disaster Recovery Logistics of Distribution Systems: Co-Optimize Service Restoration With Repair Crew and Mobile Power Source Dispatch

Repair crews (RCs) and mobile power sources (MPSs) are critical resources for distribution system (DS) outage management after a natural disaster. However, their logistics have not been well investigated. We propose a resilient scheme for disaster recovery logistics to co-optimize DS restoration with the dispatch of RCs and MPSs. A novel co-optimization model is formulated to route RCs and MPSs in the transportation network, schedule them in the DS, and reconfigure the DS for microgrid formation coordinately, etc. The model incorporates different timescales of DS restoration and RC/MPS dispatch, the coupling of transportation and power networks, etc. To ensure radiality of the DS with variable physical structure and MPS allocation, we also model topology constraints based on the concept of spanning forest. The model is convexified equivalently and linearized into a mixed-integer linear programming. To reduce its computation time, preprocessing methods are proposed to preassign a minimal set of repair tasks to depots and reduce the number of candidate nodes for MPS connection. Resilient recovery strategies thus are generated to enhance service restoration, especially by dynamic formation of microgrids that are powered by MPSs and topologized by repair actions of RCs and network reconfiguration of the DS. Case studies demonstrate the proposed methodology.

Disaster recovery logistics↗

Incorporating Wind Energy in Power System Restoration Planning

Wind energy is rapidly growing. While wind brings us clean and inexpensive energy, its inherent variability and uncertainty present challenges for the power grid. In particular, employing wind energy for power system restoration is very challenging. A fast and reliable restoration plays a vital role to achieve the self-healing power grid. This paper develops a novel offline restoration planning tool for harnessing wind energy to enhance grid resilience. The Wind-for-Restoration problem is formulated as a stochastic mixed-integer linear programming problem with generated wind energy scenarios. The problem is then decomposed into two stages and solved with the integer Lshaped algorithm. Numerical experiments have been conducted through different case studies using the modified IEEE 57-bus system. The developed tool can provide the scheduled wind power at each restoration time. The impact of wind energy is investigated from the aspects of location and inertia capability, as well as wind penetration, fluctuation, and uncertainty. Moreover, a dynamic response validation tool is developed to validate the results of optimization problem in a dynamic simulation software. Finally, simulation results demonstrate that the optimal wind harnessing strategy can help improve system restoration process and enhance system resilience.

17 WIND ENERGY↗