Search NASASearch

Engineering topics

Houghton, J. R.

Publications and source records attributed to Houghton, J. R..

Forward and reverse transfer function model synthesis

A process for synthesizing a mathematical model for a linear mechanical system using the forward and reverse Fourier transform functions is described. The differential equation for a system model is given. The Bode conversion of the differential equation, and the frequency and time-domain optimization matching of the model to the forward and reverse transform functions using the geometric simplex method of Nelder and Mead (1965) are examined. The effect of the window function on the linear mechanical system is analyzed. The model is applied to two examples; in one the signal damps down before the end of the time window and in the second the signal has significant energy at the end of the time window.

Houghton, J. R.

The application of a time-domain deconvolution technique for identification of experimental acoustic-emission signals

A method is presented for the signature analysis of pulses by reconstructing in the time domain the shape of the pulse prior to its passing through the measurement system. This deconvolution technique is first evaluated using an idealized system and analytical pulse models and is shown to provide improved results. An experimental situation is then treated; system-component models are developed for the digitizer, tape recorder, filter, transducer and mechanical structure. To accommodate both calibration results and manufacturer's data, and to provide stable mathematical models entails considerable effort: some 30 parameters must be identified to model this system - which is still a substantial approximation - albeit of very high order. Experimental pulses generated by a ball drop, spark discharge and a tearing crack are then deconvoluted 'back through' the system as modeled, using this technique. These results are compared and indicate (a) that consistent shapes may be expected from a given type of source and (b) that some sources can be identified with greater clarity using the deconvolution approach.

Houghton, J. R.

Pulse analysis of acoustic emission signals

A method for the signature analysis of pulses in the frequency domain and the time domain is presented. Fourier spectrum, Fourier transfer function, shock spectrum and shock spectrum ratio were examined in the frequency domain analysis and pulse shape deconvolution was developed for use in the time domain analysis. Comparisons of the relative performance of each analysis technique are made for the characterization of acoustic emission pulses recorded by a measuring system. To demonstrate the relative sensitivity of each of the methods to small changes in the pulse shape, signatures of computer modeled systems with analytical pulses are presented. Optimization techniques are developed and used to indicate the best design parameter values for deconvolution of the pulse shape. Several experiments are presented that test the pulse signature analysis methods on different acoustic emission sources. These include acoustic emission associated with (a) crack propagation, (b) ball dropping on a plate, (c) spark discharge, and (d) defective and good ball bearings. Deconvolution of the first few micro-seconds of the pulse train is shown to be the region in which the significant signatures of the acoustic emission event are to be found.

Houghton, J. R.

On the improvement of deconvolution with digitized data using a Runge-Kutta integration scheme

A relatively simple change in the treatment of the input function in numerical integration of high-order differential equations by Runge-Kutta methods provides substantial improvements in accuracy, particularly when the forcing function is in digitized form. The Runge-Kutta-Gill coefficients are modified to incorporate the changes; with pulse-type excitations, improvements on the order of 2 to 50 times greater accuracy are demonstrated.

Houghton, J. R.

Analysis of shock pulses for environmental tests

Specifications for shock testing of components that will be used on the Space Shuttle vehicles require very high acceleration levels. A special shock machine was built for testing of rocket components to determine if they can meet the specified accelerations. Calibrations of transducers and methods to monitor the shock tests raised several signature-analysis questions. In this report, calibration capabilities of shock accelerometers are found to be limited to 10,000g. Equivalency of the mechanical shock test and the rocket pyrotechnic shock are examined, and two simple relationships for equivalency are proposed. Five different pulse signature-analysis techniques are tested on analytical and experimental pulse data and recommendations are made for the signature technique which most clearly identifies the magnitude of the impulse applied to the test specimen.

Houghton, J. R.

Optimal design and evaluation criteria for acoustic emission pulse signature analysis

Successful pulse recording and evaluation is strongly dependent on the instrumentation system selected and the method of analyzing the pulse signature. The paper studies system design, signal analysis techniques, and interdependences with a view toward defining optimal approaches to pulse signal analysis. For this purpose, the instrumentation system is modeled, and analytical pulses, representative of the types of acoustic emissions to be distinguished are passed through the system. Particular attention is given to comparing frequency spectrum analysis and deconvolution referred to as time domain reconstruction of the pulse or pulse train. The possibility of optimal transducer-filter system parameters is investigated. Deconvolution of a pulse is shown to be a superior approach for transient pulse analysis. Reshaping of a transducer output back to the original input pulse is possible and gives an accurate representation of the generating pulse in the time domain. Any definable transducer and filter system can be used for measurement of pulses by means of the deconvolution method. Selection of design variables for general usage is discussed.

Houghton, J. R.

Pulse analysis of acoustic emission signals

A method for the signature analysis of pulses in the frequency domain and the time domain is presented. Fourier spectrum, Fourier transfer function, shock spectrum and shock spectrum ratio were examined in the frequency domain analysis, and pulse shape deconvolution was developed for use in the time domain analysis. Comparisons of the relative performance of each analysis technique are made for the characterization of acoustic emission pulses recorded by a measuring system. To demonstrate the relative sensitivity of each of the methods to small changes in the pulse shape, signatures of computer modeled systems with analytical pulses are presented. Optimization techniques are developed and used to indicate the best design parameters values for deconvolution of the pulse shape. Several experiments are presented that test the pulse signature analysis methods on different acoustic emission sources. These include acoustic emissions associated with: (1) crack propagation, (2) ball dropping on a plate, (3) spark discharge and (4) defective and good ball bearings. Deconvolution of the first few micro-seconds of the pulse train are shown to be the region in which the significant signatures of the acoustic emission event are to be found.

Houghton, J. R.

Pulse analysis of acoustic emission signals

A method for the signature analysis of pulses in the frequency domain and the time domain is presented. Fourier spectrum, Fourier transfer function, shock spectrum and shock spectrum ratio are examined in the frequency domain analysis, and pulse shape deconvolution is developed for use in the time domain analysis. To demonstrate the relative sensitivity of each of the methods to small changes in the pulse shape, signatures of computer modeled systems with analytical pulses are presented. Optimization techniques are developed and used to indicate the best design parameters values for deconvolution of the pulse shape. Several experiments are presented that test the pulse signature analysis methods on different acoustic emission sources. These include acoustic emissions associated with: (1) crack propagation, (2) ball dropping on a plate, (3) spark discharge and (4) defective and good ball bearings.

Houghton, J. R.