Correlated color temperature is not a suitable proxy for the biological potency of light

Using a simulation based on a real, five-channel tunable LED lighting system, we show that Correlated Color Temperature (CCT) is not a reasonable predictor of the biological potency of light, whether characterized with CIE melanopic Equivalent Daylight Illuminance (mel-EDI), Equivalent Melanopic Lux (EML) (a scalar multiple of mel-EDI), or Circadian Stimulus (CS). At a photopic corneal illuminance of 300 lx and Rf ≥ 70, spectra can vary in CS from 17 to 41% across CCTs from 2500 to 6000 K, and up to 23% at a single CCT, due to the choice of spectrum alone. The CS range is largest, and notably discontinuous, at a CCT of 3500 K, the location of the inflection point of the CS model. At a photopic corneal illuminance of 300 lx and Rf ≥ 70, mel-EDI can vary from 123 to 354 lx across CCTs from 2500 to 6000 K and can vary by up to 123 lx at a fixed CCT (e.g., 196 to 319 lx at 5000 K). The range of achievable mel-EDI increases as CCT increases and, on average, decreases as color fidelity, characterized with IES TM-30 Rf, increases. These data demonstrate that there is no easy mathematical conversion between CS and mel-EDI when a spectrally diverse spectra set of spectral power distributions is considered.

60 APPLIED LIFE SCIENCES↗

Improved Method for Evaluating and Specifying the Chromaticity of Light Sources

This article recommends a method for calculating and specifying light source chromaticity using the CIE 2015 10° color matching functions (CMFs), which, according to analysis of existing psychophysical experiment data, can reduce visual mismatch compared to specifications based on the traditional CIE 1931 2° CMFs. Specifically, this work evaluates, documents, and recommends for adoption a supporting system of measures to be used with the CIE 2015 10° CMFs: a new uniform chromaticity scale (UCS) diagram with coordinates (s, t), a measure of correlated color temperature (CCTst), and a measure of distance from the Planckian locus (Dst). It also presents options for updating nominal classification quadrangles. A complete method of this nature has not yet been standardized, which may be contributing to the slow uptake of the CIE 2015 CMFs. The proposed tools are analogous to u, v, CCT, Duv, and the ANSI C78.377 nominal classification quadrangles that are currently specified in the CIE 1960 UCS using the CIE 1931 2° CMFs. While conceptually equivalent, the differences between the current standard method and the new st system are important for reducing unintended mismatch in the chromaticity of light. Furthermore, the implications of changing chromaticity specification methods are identified by a comparison over a diverse set of real light source SPDs. Finally, as a step toward improving the design and specification of light sources for illumination purposes, we propose a process for implementing the recommendations.

42 ENGINEERING↗