Search NASA⌕ Search

Engineering topics

Housley, Catherine E.

Publications and source records attributed to Housley, Catherine E..

Magnetic Materials Research at SRNL

Introduction – What are Magnetic Materials? Magnetic materials are crystalline solids which below a certain temperature, known as the ordering temperature, display spontaneous order in their magnetic moments. Results • Enhanced thermal stability and saturation magnetization with Y substitution in Ce2Fe14B based permanent magnets • Discovered a new ferromagnetic phase transition at TC = 62.9 K in (Dy1/3Mo2/3)2AlC and validated the two previously reported low temperature magnetic phases Characterization of Magnetic Materials Raw high purity materials are melted together to synthesize a crystalline sample using an arc melter at Savannah River National Laboratory (SRNL). Use high energy ball milling to form a hard/soft magnetic composite using Y substituted Ce2Fe14B. Finish structural characterization on γ- irradiated (RE1/3Mo2/3)2AlC (RE = Rare Earth) MAX samples. Unit Cell Lattice Points

Bretana, Alex↗

Synthesis and characterization of properties of (Tb1/3Mo2/3)2AlC polycrystalline

When molecules, atoms, or ions are grouped in a highly ordered microscopic structure to form a crystal lattice that stretches in all directions, the result is a solid material known as a crystal or crystalline solid. They are arranged in a highly ordered microscopic structure to form a crystal lattice. The smallest group of particles in material that constitutes this repeating pattern is unit cell of the structure. The unit cell is a repeating unit formed by the vectors spanning the points of a lattice.

Bretana, Alex↗

Magnetic Materials Research at SRNL

Fig: Rietveld Refinement of room temperature PXRD data for annealed Ce2Fe14B (left panel), (Y0.1Ce1.9)Fe14B (middle panel), and (Lu0.1Ce1.90)Fe14B (right panel) alloys. All annealed alloys plotted are composed primarily of Ce2Fe14B phase with small α-Fe impurities. Vertical blue ticks correspond to the position of the calculated Bragg peaks of all phases (from top to bottom, 2-14-1 and α-Fe). Fig: (Left Panel) Field dependent magnetization measurements on aligned powder with the magnetic field applied along the easy direction for annealed Ce2Fe14B and (YxCe2-x)Fe14B (x=0.1, 0.2, 0.3, 0.4, 0.5) alloys. (Middle Panel) Field dependent magnetization measurements on aligned powder with the magnetic field applied along the hard direction for annealed Ce2Fe14B and (YxCe2-x)Fe14B (x=0.1, 0.2, 0.3, 0.4, 0.5) alloys. (Right Panel) The saturation magnetization of Ce2Fe14B and (YxCe2-x)Fe14B (x=0.1, 0.2, 0.3, 0.4, 0.5) alloys as determined from easy axis field dependent magnetization measurements.

Bretana, Alex↗

Magnetic properties of Lutetium and Yttrium doped Ce 2 Fe 14 B magnets

The increasing demand for Nd-Dy and Sm-Co based permanent magnets is exacerbating the current critical materials shortage, therefore improving and optimizing current candidate critical element free permanent magnets is necessary to develop future clean energy technologies. In this work, we aim to increase the thermal stability and magnetic performance of Ce 2 Fe 14 B based permanent magnets through the substitution of Ce ions with noncritical rare earth elements Lu and Y. The substitution of Lu (x=0; 0.05; 0.1; 0.15) for Ce ions in (LuxCe 2-x )Fe 14 B was unsuccessful, likely due to disparities in ionic size and valencies, and failed to exhibit improved thermal stability or magnetic performance. In contrast, Y substitution for Ce ions in (Y x Ce 2-x )Fe14B (x= 0.1; 0.2; 0.3; 0.4; 0.5) alloys was successful. Notably, these alloys demonstrated enhanced thermal stability, as evidenced by an increase in the Curie temperature, reaching a peak of 443 K at x= 0.5. Y substitution also helped to suppress the CeFe2 Laves phase. Without loss of the anisotropy field Y substitution increased the saturation magnetization, MS, peaking at MS = 125 emu/g for a Y concentration of x= 0:4, demonstrating (Y 0.4 Ce 1.6 )Fe 14 B as a potential critical element free permanent magnet with an energy product as high as 29 MGOe. This work is advantageous in developing low cost high performance permanent magnets with reduced or little to no critical rare earth elements.

Rai, Binod K.↗

Magnetic properties of Lu and Y doped Ce-Fe-B magnets

The growing demand for Nd2Fe14B magnets is exacerbating the current critical materials shortage. To reduce the amount of critical material in Nd2Fe14B magnets, chemical substitutions have been used and shown to improve the magnetic behavior, such as the Curie Temperature TC, anisotropy field Ha, and saturation magnetization MS.

Bretana, Alex↗

Evaluation of Expansion in ETF Grout Compositional Variants

In summary, the Base Case grout, Mix K, prepared according to the protocol provided (short stirring time after struvite precipitation of about 30 minutes) expanded when cured in a dry and damp sealed bag. Two variants, Mix M, 100 % slag in the dry mix, did not expand when prepared and cured under the same dry and damp conditions. Mix L, precipitated struvite removed, showed very slight expansion after curing 289 days for both dry and damp curing which was expressed as slight bulging at the bottom of the container. Mix N, 100 % dilution of the simulant, did not expand when cured under dry conditions or in a sealed container in damp conditions. However, a cylinder of Mix N cured in a container that was slit and taped back together did expand in damp conditions. This condition enabled the grout to be exposed to more moisture that the grout sample cured in the capped container and stored in the same zip top bag with the damp towel. This information is provided to support processing and containerization of the ETF ammonia grout.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Particle Size Analysis and Distribution

Scanning Electron Microscope (SEM) is a instrument used for examining samples at magnifications from 32 X to 500,000 X (for our instrument). The SEM is attached with an electron gun and is directed onto the sample. The sample then produces an image where it is read on the monitor. The electron gun is positioned at the top because it needs to shoot at the sample that is being tested. The electrons are then shot in a downward motion traveling through several lenses, such as the condenser lens for a more precise reading. Once the samples have been read by the instrument, it will show a picture that has a certain number of particles. Particle size distribution have many uses that are essential to life habits (health) or even conventional use for example construction. Here are just a few examples of how particle size analysis and distribution are being used even today. This Standard Reference Material (SRM) is primarily intended for use in the calibration of equipment used to measure particle size distributions (PSD) in the 9 μm to 30 μm range. A unit of SRM 1984 consists of a single bottle containing approximately 14 g of tungsten carbide/cobalt powder. Certified values: The PSD values at five mass percentiles were measured by scanning electron microscopy (SEM) and laser light scattering (LLS). The NIST certified PSD values by SEM are listed. These certified values were determined by the measurement of over 10 000 individual particles from three bottles. Comparing the certified NIST SRM 1984 tungsten carbide/cobalt powder with our results are almost identical. This is great because more accurate work can be done and proves that our laboratory is able to reproduce NIST results. In conclusion, the scanning electron microscope is used to capture the sampled element and display it to be counted. Without the use of particle distribution, it would be a difficult time to get necessities such as medicine, asthma pumps, constructing materials, or as simple as ink. Overall, our study is an experimental comparison of the techniques we have in house, which are LLS and SEM (combined with the NIH ImageJ software) using the NIST SRM-1984 as a common, well characterized sample so that we have an idea of how the results from the techniques compare.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-Ray Fluorescence Quantitative and Qualitative Analysis Using Micro Glass Beads

The fused glass bead method is the accepted 'best practice' method of preparation of samples for X-ray fluorescence (XRF) analysis. It minimizes the effects of sample heterogeneity and simplifies calibration by dissolving the sample into a uniform glass matrix. Glass fusion XRF samples are typically prepared by grinding sample powder with Lithium Tetraborate / Lithium Bromide and fusing the mixture at 1000 deg. C. In most cases sample-to-flux ratios of between 1:1 to 1:10 are used (1:1 for determination of trace elements and 1:10 for major elements). Typical sample mass consumed is in the range of 1000 to 2500 mg. It would be advantageous to reduce this sample mass in cases where the sample material is rare, valuable or highly radioactive. This study examines the effects of using lower sample-to-flux ratios and smaller fusion bead size on the detection and quantification of major and trace elements by XRF analysis. We have employed a micro fused glass bead process, using sample-to-flux ratios of 1:10, 1:15 and 1:25, to determine the effects on measurement precision, accuracy and detection limit. Objectives: - Created micro fused glass beads of a series of standards and andesite sample with sample-to-flux ratios of 1:10, 1:15 and 1:25. - Perform an qualitative analysis of the different sample-to-flux ratio micro beads and compare the results with the 1:5.3 beads routinely used at SRNL. - Quantitate the major components in the different sample-to-flux ratio micro beads using a wavelength dispersive x-ray fluorescence instrument. Advantages: - Reduce sample amount needed. - Speed up waste tank characterization. - Reduce personnel exposure. - Potential sealed source. Fused micro glass beads with sample-to-flux ratios of 1:10, 1:15 and 1:25 were created using sample amounts of 123 mg, 82 mg and 52 mg respectively. It was possible to detect most of the major oxides and some trace elements in the fused micro glass beads with different sample-to-flux ratios. The quantitative analysis showed good linear correlation between the intensity of the analysis and the concentration of the elements. Good precision and accuracy results were obtained for the majority of the major oxides in the three fused micro glass beads with different sample-to-flux ratios. Path Forward: Enhance the precision and accuracy of the method by optimizing different sample preparation steps, such as weighing and sample transfer. Continue to increase the sample-to-flux ratio to determine the minimum amount of sample needed to perform a multielement analysis. Consider the use of synthetic standards to lower the detection limit of the analysis. Used the micro bead sample preparation method to analyze radioactive samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗