Search NASA⌕ Search

Engineering topics

Houssainy, Sammy

Publications and source records attributed to Houssainy, Sammy.

From Chills to Thrills: Revolutionizing Energy Efficiency and Load Flexibility in Supermarket Refrigeration

Open-vertical medium-temperature refrigerated display cases comprise nearly 50% of total case lineups in a typical supermarket, with more than 80% of their cooling load attributed to infiltration of warm and moist air from the surrounding space. The infiltration takes place across the air curtain system of the display case. While the air curtain acts as a thermal shield and as a cooling mechanism to maintain product temperature, it also entrains large amounts of heat and moisture from the adjacent space. Additionally, from food safety and quality standpoints, these fixtures are vulnerable to electric outages and traditionally cannot participate in load flexibility events. This paper describes key features of an innovative design of a self-contained, water-cooled, medium-temperature, open-vertical display case. The novel concept will eliminate the inefficient air curtain system and incorporate a hybrid radiant and low-airflow convective cooling design with a thermal-energy-storage-coupled heat exchanger integrated into the refrigeration circuit. The focus of this paper is on evaluating the thermal performance of the novel hybrid design in maintaining target product temperature. It presents thermal performance findings from thermo-fluid system modeling and robust state-of-the-art laboratory experiments used to validate those models. Load flexibility attributes from thermal energy storage are not discussed. A controlled-environment chamber at the National Renewable Energy Laboratory was leveraged to validate the thermal performance of the novel technology. Final results from bench-scale experiments indicate the proposed design maintained mean product temperatures within food safety guidelines.

commercial refrigeration↗

Embodied Carbon Resource Navigator

The Embodied Carbon Resource Navigator is a guide to help architects, engineers, designers, contractors, and those who want to reduce their embodied carbon impact make more informed design decisions for buildings. The guide is a compilation of embodied carbon resources, organized by experience level to direct the user to the necessary resources.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Developing and tuning a community scale energy model for a disadvantaged community

This work describes the development of a community-scale energy model for a mixed-use low-income community located in Huntington Beach, CA. An accurate community-scale energy model is useful for evaluating the use of limited capital resources used to invest in clean energy technologies. This work lays out the process of developing such a model while relying primarily on publicly available data and highlighting critical partnerships necessary for model development success. The primary contribution of this work is the demonstration of the process used to develop an accurate energy model for a disadvantaged community when minimal building and energy use data is available. The heart of the model is the physics-based community scale energy modeling platform URBANopt. Using a bottom-up load modeling approach, energy simulated energy use falls within 3% or less of aggregate annual utility data, and within 10% or less aggregate monthly utility data. The demonstrated model development and tuning process can be used by others to characterize other atypical communities, which may differ significantly from prototypical models.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Optimal strategies for a cost-effective and reliable 100% renewable electric grid

This paper explores cost-optimal pathways to 100% renewable power systems for the U.S. building stock. We show that long-duration misalignments of supply and demand, spanning from multi-day to seasonal timescales, present a dominant challenge that must be addressed to meet real-time 100% renewable targets. While long-duration misalignments can be addressed through energy storage, we show that alternative and readily available solutions that are more cost-effective should be considered first. Through a techno-economic analysis, we identify cost-optimal, region-dependent, supply-side, and demand-side strategies that reduce, and in some U.S. regions eliminate, the otherwise substantial capacities and associated costs of long-duration energy storage. Investigated supply-side strategies include optimal mixes of renewable portfolios and oversized generation capacities. Considered demand-side strategies include building load flexibility and building energy efficiency investments. Our results reveal that building energy efficiency measures can reduce long-duration storage requirements at minimum total investment costs. In addition, oversizing and diversifying renewable generation can play a critical role in reducing storage requirements, remaining cost effective even when accounting for curtailed generation. We identify regionally dependent storage cost targets and show that for emerging long-duration energy storage innovations to achieve broad adoption, their costs will need to compete with the decreasing cost of renewables. The findings of this research are particularly important given that most long-duration storage technologies are currently either uneconomical, geologically constrained, or still underdeveloped.

100% renewable↗

A Guide to Energy Master Planning of High-Performance Districts and Communities

This guide was developed with partners throughout the United States to demonstrate how implementing district-scale high-performance strategies can be successful and scalable approaches to achieving deep energy savings that increase affordability, improve resilience, reduce emissions, and foster economic development. This document serves as a framework for districts, campuses, and communities, illustrating an iterative process of building support for, planning, and implementing high-performance districts by engaging stakeholders, setting aggressive energy goals, completing technical and financial planning, and implementing a high-performance energy master plan. The information in this guide is based on a 3-year U.S. Department of Energy Zero Energy District Accelerator and a range of real-world examples of emerging high-performance districts. It is particularly useful for architects, planners, engineers, local government agencies, and real estate developers in the early phases of planning a district with high-performance or other deep energy goals. For the purposes of this guide, a high-performance district is a multibuilding development that achieves aggressive energy and related goals such as zero energy, carbon neutrality, sustainability, ultra-efficiency, etc. High-performance districts optimize energy efficiency to reduce energy loads and use renewable energy resources to meet the remaining loads whenever possible. The Energy Independence and Security Act of 2007 defines a high-performance building as “a building that integrates and optimizes on a life cycle basis all major high-performance attributes, including energy conservation, environment, safety, security, durability, accessibility, cost-benefit, productivity, sustainability, functionality, and operational considerations.” High-performance districts are collections of such buildings that take advantage of the synergies available when energy consumption and production are considered at a district level rather than one building at a time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Empowering Energy Efficiency in Existing Big-Box Retail/Grocery Stores (Final Optimization Report)

The Center for Sustainable Energy (CSE), in partnership with the National Renewable Energy Laboratory (NREL), TRC Energy Services, P2S Engineering Inc, Walmart, and five innovative technology providers, are to demonstrate the impact of an integrated suite of pre-commercial energy efficiency (EE) technologies in a large, existing, retail building located within an inland disadvantaged community. Proposed technology packages include three categories of advanced EE solutions: heating, ventilating, air-conditioning, and refrigerating (HVAC/R); lighting; and integrated system and building level controls. The project is designed to impact Walmart’s future store specifications, which can be replicated and deployed in other buildings across California with similar end-use and system characteristics. The following lists the technologies considered for this project: DualCool (HVAC evaporative cooling); Software Motor Company (SMC) (HVAC and refrigeration fan motor); I2S: DC LED lighting; LocBit: building energy management and optimization; Saya: water monitoring.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Closed-form theoretical model of the secondary drop size in partial coalescence—Capturing pertinent timescales and viscous forces

One of the most important outcomes of partial drop coalescence is the ratio of the secondary drop radius to the primary drop radius, known as the drop ratio, ri. This ratio is thought to be approximately constant and independent of physical parameters of the fluids involved. However, here we reveal that ambient fluid viscosity can alter the size of the secondary drop and the drop ratio consequently. Using scaling analysis, we derive a model that predicts the behavior of the drop ratio as a function of the Ohnesorge number, a dimensionless ratio of viscous to inertial forces. In addition, we present our experimental results of coalescing drops on a planar interface under the influence of surface tension gradients. A high-speed digital camera is used to observe the evolution of drops as they coalesce with a bulk liquid. We show that this process is influenced by the surface tension gradient between the drop and the bulk liquid. The ratio of the secondary drop to the primary drop in partial coalescence is smaller than the reported values for coalescence without a surface tension gradient. The analytical model derived through this study is based on a new modified Ohnesorge number that includes surface tension gradients. Our analytical model is compared against other models and the results illustrate good agreement with our experimental findings and experimental data in the literature.

42 ENGINEERING↗

Performance of an Isobaric Hybrid Compressed Air Energy Storage System at Minimum Entropy Generation

Efficient, large-scale, and cost-effective energy storage systems provide a means of managing the inherent intermittency of renewable energy sources and drastically increasing their utilization. Compressed air energy storage (CAES) and its derivative architectures have received much attention as a viable solution; however, optimization objectives for these systems have not been thoroughly investigated in the literature. In this work, a hybrid thermal and compressed air energy storage (HT-CAES) system is investigated that mitigates the shortcomings of the otherwise attractive conventional CAES systems and its derivatives—shortcomings such as strict geological locations, low energy densities, and the production of greenhouse gas emissions. The HT-CAES system allows a portion of the available energy to operate a compressor and the remainder to be converted and stored in the form of heat through joule/resistive heating in a high-temperature, sensible, thermal energy storage medium. Internally reversible and irreversible HT-CAES system assumptions were investigated, in addition to regenerative and non-regenerative design configurations. Several system optimization criteria were examined—including maximum energy efficiency, maximum exergy efficiency, maximum work output, and minimum entropy generation—with a focus on whether the latter may lead to conclusive design guidelines in a real system. It is shown that an HT-CAES system designed based on a minimum entropy generation objective may operate at a lower energy and exergy efficiency as well as lower output power than otherwise achievable. Furthermore, optimization objective equivalence is shown to be limited to certain design conditions.

25 ENERGY STORAGE↗

Theoretical Performance Limits of an Isobaric Hybrid Compressed Air Energy Storage System

Furthermore, the desire to increase power production through renewable sources introduces a number of problems due to their inherent intermittency. One solution is to incorporate energy storage systems as a means of managing the intermittent energy and increasing the utilization of renewable sources. A novel hybrid thermal and compressed air energy storage (HT-CAES) system is presented which mitigates the shortcomings of the otherwise attractive conventional compressed air energy storage (CAES) systems and its derivatives, such as strict geological locations, low energy density, and the production of greenhouse gas emissions. The HT-CAES system is investigated, and the thermodynamic efficiency limits within which it operates have been drawn. The thermodynamic models considered assume a constant pressure cavern. It is shown that under this assumption the cavern acts just as a delay time in the operation of the plant, whereas an adiabatic constant volume cavern changes the quality of energy through the cavern. The efficiency of the HT-CAES system is compared with its Brayton cycle counterpart, in the case of pure thermal energy storage (TES). It is shown that the efficiency of the HT-CAES plant is generally not bound by the Carnot efficiency and always higher than that of the Brayton cycle, except for when the heat losses following compression rise above a critical level. The results of this paper demonstrate that the HT-CAES system has the potential of increasing the efficiency of a pure TES system executed through a Brayton cycle at the expense of an air storage medium.

25 ENERGY STORAGE↗

Thermodynamic performance and cost optimization of a novel hybrid thermal-compressed air energy storage system design

Compressed Air Energy Storage (CAES) can potentially allow renewable energy sources to meet electricity demands as reliably as coal-fired power plants. However, conventional CAES systems rely on the combustion of natural gas, require large storage volumes, and operate at high pressures, which possess inherent problems such as high costs, strict geological locations, and the production of greenhouse gas emissions. A novel and patented hybrid thermal-compressed air energy storage (HT-CAES) design is presented which allows a portion of the available energy, from the grid or renewable sources, to operate a compressor and the remainder to be converted and stored in the form of heat, through joule heating in a sensible thermal storage medium. The HT-CAES design incudes a turbocharger unit that provides supplementary mass flow rate alongside the air storage. The hybrid design and the addition of a turbocharger have the beneficial effect of mitigating the shortcomings of conventional CAES systems and its derivatives by eliminating combustion emissions and reducing storage volumes, operating pressures, and costs. Storage efficiency and cost are the two key factors, which upon integration with renewable energies would allow the sources to operate as independent forms of sustainable energy. The potential of the HT-CAES design is illustrated through a thermodynamic optimization study, which outlines key variables that have a major impact on the performance and economics of the storage system. The optimization analysis quantifies the required distribution of energy between thermal and compressed air energy storage, for maximum efficiency, and for minimum cost. This study provides a roundtrip energy and exergy efficiency map of the storage system and illustrates a trade off that exists between its capital cost and performance.

25 ENERGY STORAGE↗