Search NASA⌕ Search

Engineering topics

Howard, Marylesa

Publications and source records attributed to Howard, Marylesa.

X-ray induced grain boundary formation and grain rotation in Bi 2 Se 3

Optimizing grain boundary characteristics in polycrystalline materials can improve their properties. Many processing methods have been developed for grain boundary manipulation, including the use of intense radiation in certain applications. Here, in this work, we used X-ray free electron laser pulses to irradiate single-crystalline bismuth selenide (Bi 2 Se 3 ) and observed grain boundary formation and subsequent grain rotation in response to the X-ray radiation. Our observations with simultaneous transmission X-ray microscopy and X-ray diffraction demonstrate how intense X-ray radiation can rapidly change size and texture of grains.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simultaneous bright- and dark-field X-ray microscopy at X-ray free electron lasers

Abstract The structures, strain fields, and defect distributions in solid materials underlie the mechanical and physical properties across numerous applications. Many modern microstructural microscopy tools characterize crystal grains, domains and defects required to map lattice distortions or deformation, but are limited to studies of the (near) surface. Generally speaking, such tools cannot probe the structural dynamics in a way that is representative of bulk behavior. Synchrotron X-ray diffraction based imaging has long mapped the deeply embedded structural elements, and with enhanced resolution, dark field X-ray microscopy (DFXM) can now map those features with the requisite nm-resolution. However, these techniques still suffer from the required integration times due to limitations from the source and optics. This work extends DFXM to X-ray free electron lasers, showing how the $$10^{12}$$ 10 12 photons per pulse available at these sources offer structural characterization down to 100 fs resolution (orders of magnitude faster than current synchrotron images). We introduce the XFEL DFXM setup with simultaneous bright field microscopy to probe density changes within the same volume. This work presents a comprehensive guide to the multi-modal ultrafast high-resolution X-ray microscope that we constructed and tested at two XFELs, and shows initial data demonstrating two timing strategies to study associated reversible or irreversible lattice dynamics.

47 OTHER INSTRUMENTATION↗

Analytical methods for superresolution dislocation identification in dark-field X-ray microscopy

In this work, we develop several inference methods to estimate the position of dislocations from images generated using dark-field X-ray microscopy (DFXM)—achieving superresolution accuracy and principled uncertainty quantification. Using the framework of Bayesian inference, we incorporate models of the DFXM contrast mechanism and detector measurement noise, along with initial position estimates, into a statistical model coupling DFXM images with the dislocation position of interest. We motivate several position estimation and uncertainty quantification algorithms based on this model. We then demonstrate the accuracy of our primary estimation algorithm on synthetic realistic DFXM images of edge dislocations in single-crystal aluminum. We conclude with a discussion of our methods’ impact on future dislocation studies and possible future research avenues.

36 MATERIALS SCIENCE↗

An automated approach to the alignment of compound refractive lenses

Compound refractive lenses (CRLs) are established X-ray focusing optics, and are used to focus the beam or image the sample in many beamlines at X-ray facilities. While CRLs are quite established, the stack of single lens elements affords a very small numerical aperture because of the thick lens profile, making them far more difficult to align than classical optical lenses that obey the thin-lens approximation. This means that the alignment must be very precise and is highly sensitive to changes to the incident beam, often requiring regular readjustments. Some groups circumvent the full realignment procedure by using engineering controls ( e.g. mounting optics) that sacrifice some of the beam's focusing precision, i.e. spot size, or resolution. While these choices minimize setup time, there are clear disadvantages. This work presents a new automated approach to align CRLs using a simple alignment apparatus that is easy to adapt and install at different types of X-ray experiments or facilities. This approach builds on recent CRL modeling efforts, using an approach based on the Stochastic Nelder–Mead (SNM) simplex method. This method is outlined and its efficacy is demonstrated with numerical simulation that is tested in real experiments conducted at the Advanced Photon Source to confirm its performance with a synchrotron beam. This work provides an opportunity to automate key instrumentation at X-ray facilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗