Noninvasive measures of bone bending rigidity in the monkey /M. nemestrina/

The in vivo bending rigidity and bone mineral content of monkey ulnae and tibiae were measured. Bending rigidity in the anteroposterior plane was measured by an impedance probe technique. Forced vibrations of the bones were induced with an electromechanical shaker, and force and velocity at the driving point were determined. The responses over the range of 100-250 Hz were utilized to compute the bending rigidity. Bone mineral content in the cross section was determined by a photon absorption technique. Seventeen male monkeys (Macaca nemestrina) weighing 6-14 kg were evaluated. Bending rigidity was correlated with the mineral content of the cross section, with a correlation coefficient of 0.899. Two monkeys were evaluated during prolonged hypodynamic restraint. Restraint produced regional losses of bone most obviously in the proximal tibia. The local bone mineral content declines 17 to 24% and the average bending rigidity declines 12 to 22%. Changes in bones leading to a reduction in mineral content and stiffness are discussed.

Young, D. R.

Tread drum for animals

A device for exercising animals such as primates is described, which includes a cylindrical housing mounted for rotation about a horizontal axis of revolution and has a cylindrical treadway portion on which the animal treads while the drum is rotated by means of a motorized drive. The treadway portion of the drum includes an electrode structure with sectors being independently energizable by means of a commutator and source of potential so that an electrical shock station is created behind a running-in-place station on the moving treadway. In this manner, if the animal should fall behind its running-in-place station, it may be shocked by treading on the energized electrode structure. One end of the tread drum comprises a transparent wall for unobstructed viewing of the animal being exercised.

Howard, W. H.

In-vivo bone strain telemetry in monkeys /M. nemestrina/

A new method for collecting in-vivo bone strain data in monkeys has been developed and tested. The method includes a system which consists of a new design of implantable strain transducer and its companion telemetry package. The transducer fits into a hole drilled in a monkey tibia and is threaded for subsequent bone ingrowth. The transducers and telemetry package are biocompatible for over 503 days. The telemetry package uses Pulse Interval Ratio Modulation (PIRM) to transmit strain information to receiving equipment located outside the animal housing cage.

Young, D. R.

In vivo bone-strain telemetry

System permits long-term measurement of strains resulting from applied skeletal loads. Basic scheme utilizes pulse interval modulation.

Young, D. R.

Programmable physiological infusion

A programmable physiological infusion device and method are provided wherein a program source, such as a paper tape, is used to actuate an infusion pump in accordance with a desired program. The system is particularly applicable for dispensing calcium in a variety of waveforms.

Howard, W. H.

Weight simulator

Device applies compressive force to bone to minimize loss of bone calcium during weightlessness or bedrest. Force is applied through weights, or hydraulic, pneumatic or electrically actuated devices. Device is lightweight and easy to maintain and operate.

Howard, W. H.

Programmed physiological infusion system

Infusion system delivers incremental volumes from a reservoir with a piston pump at a rate that varies in time and follows the envelope of a preprogrammed curve.

Howard, W. H.