Measurement of free chlorine levels in water using potentiometric responses of biofilms and applications for monitoring and managing the quality of potable water

We report residual free chlorine is not monitored continuously at scale in drinking water distribution systems because existing real-time sensor technologies require frequent maintenance, cleaning, and calibration, which makes these products too costly to be used throughout a distribution system. As a result, current measurement approaches require manual sampling, which is not feasible for the consistent monitoring of free chlorine because chlorine concentrations vary significantly throughout pipeline distribution and over time and space. This research presents an alternative and cost-effective method of predicting free chlorine levels in drinking water using graphite electrodes coated with naturally grown microbial biofilms. This Microbial Potentiometric Sensor (MPS) array was installed in a Continuously Mixed Batch Reactor (CMBR), and drinking water containing variable free chlorine concentrations. The chlorine concentrations were introduced in a controlled manner, and the MPS signals were monitored over time. MPS signals were measured from the change in Open Circuit Potential (OCP) across the MPS array in real-time. An empirically derived relationship between the normalized change in OCP and free chlorine was established by fitting individual and average MPS data to a decaying exponential growth function in order to predict free chlorine levels. The results show that free chlorine can be predicted with reasonable accuracy, with model validation showing an average absolute error of ±0.09 ppm below 1.1 ppm and ±0.30 ppm between 1.1 and 2.7 ppm. However, the accuracy of predictions was reduced at higher free chlorine levels. The researchers conclude that MPS systems may benefit drinking water distribution systems by measuring free chlorine. These advantages of the MPS are especially pronounced in the developing world because this system is inexpensive and does not require routine maintenance or cleaning. The system relies on a naturally forming and regenerating biofilm and an inexpensive potentiometric meter to produce stable measurements.

54 ENVIRONMENTAL SCIENCES↗

Microbial potentiometric sensor technology for real-time detecting and monitoring of toxic metals in aquatic matrices

Considering that toxic metals can affect metabolic processes in microorganisms adversely, it can be hypothesized that these metals in water matrices would induce a decrease in metabolic activity of the biofilm microorganisms populating the surface of a sensing electrode, which could be registered as a change in the open-circuit potential (OCP) generated by the biofilm microorganisms. The goal of this study was to test this hypothesis and demonstrate the underlying principle that microbial potentiometric sensor (MPS) technology could be used for long-term and real-time monitoring and detection of rapid changes in metal concentrations in realistic aquatic environments. To address the goal, four objective were addressed: (1) a batch reactor with three graphite-based MPS electrodes was fabricated; (2) a set of single-ion solutions and one multiple ion solution were prepared reflecting realistic concentrations of metals found in electroplating wastewaters; (3) the responses of the MPS to the simultaneous presence of multiple toxic metal ions in a single solution were measured; and (4) the changes of the MPS signals to the presence of individual metal ion solutions were examined. While the hypothesis was validated, the study also revealed that the MPS was sufficiently sensitive to not only detect, but also quantify, toxic metal ion concentrations in aqueous solutions. The coefficients of determination, which were R 2 > 0.995, and responsiveness of <1 μmol/L for some toxic metal cations, strongly support the performance of MPS technology in the echelons of expensive analytical tools capable detecting and measuring trace elements.The magnitude of the MPS response was toxic metal specific. When the molar concertation normalizes the inhibition portion of the signal area, the assessed sensitivity order was: Se>Cd>Pb>Ag>Ni> Zn. The study provides valuable information for enforcement agents, environmental professionals, and wastewater treatment operators, so toxic metal pollution and its detrimental impacts can be prevented and mitigated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Real-time monitoring and prediction of water quality parameters and algae concentrations using microbial potentiometric sensor signals and machine learning tools

We report the overarching hypothesis of this study was that temporal microbial potentiometric sensor (MPS) signal patterns could be used to predict changes in commonly monitored water quality parameters by using artificial intelligence/machine learning tools. To test this hypothesis, the study first examines a proof of concept by correlating between MPS's signals and high algae concentrations in an algal cultivation pond. Then, the study expanded upon these findings and examined if multiple water quality parameters could be predicted in real surface waters, like irrigation canals. Signals generated between the MPS sensors and other water quality sensors maintained by an Arizona utility company, including algae and chlorophyll, were collected in real time at time intervals of 30 min over a period of 9 months. Data from the MPS system and data collected by the utility company were used to train the ML/AI algorithms and compare the predicted with actual water quality parameters and algae concentrations. Based on the composite signal obtained from the MPS, the ML/AI was used to predict the canal surface water's turbidity, conductivity, chlorophyll, and blue-green algae (BGA), dissolved oxygen (DO), and pH, and predicted values were compared to the measured values. Initial testing in the algal cultivation pond revealed a strong linear correlation (R 2 = 0.87) between mixed liquor suspended solids (MLSS) and the MPSs' composite signals. The Normalized Root Mean Square Error (NRMSE) between the predicted values and measured values were <6.5%, except for the DO, which was 10.45%. The results demonstrate the usefulness of MPSs to predict key surface water quality parameters through a single composite signal, when the ML/AI tools are used conjunctively to disaggregate these signal components. The maintenance-free MPS offers a novel and cost-effective approach to monitor numerous water quality parameters at once with relatively high accuracy.

54 ENVIRONMENTAL SCIENCES↗

Microbial potentiometric sensor: A new approach to longstanding challenges

The underlying hypothesis of this study is that simple potentiometric measurements between sensing electrodes and a shared reference electrode - Microbial Potentiometric Sesnor (MPS) system - can be employed in a long-term, continuous mode of operation to resolve the spatial and temporal changes in environmental systems. To address the hypothesis, (1) a conceptual description of the MPS system and its postulated principle of operation are provided; (2) the MPS system performance is documented under controlled laboratory conditions; and (3) the capabilities of the MPS system are documented under quiescent and dynamic field condition. In a laboratory setting, the variability among different MPS signals was insignificant confirming the postulated high accuracy and reproducibility of the sensor performance. It also demonstrated statistically significant correlations with dissolved oxygen (DO) and oxidation-reduction potential (ORP) sensors, while showing capabilities of operating under anoxic and anaerobic conditions. Regardless of their locations in the model wetland system, three MPS sensors functioned without interruption and cleaning for a period >2 years, and thus demonstrating long-term durability of the MPS technology. In real batch-wastewater treatment facility, the deployed MPS system signals were able to describe the organic carbon trends and correlate with each treatment phase in a cycle. Data reproducibility and reliability exceeded the expectations better describing the carbon treatment levels than the DO and ORP sensors (p < 4.4 × 10 –162 vs phase adjusted p < 3.0 × 10 –58 ). While MPS signals correlate with specific parameters that describe the local process or environments, it is more prudent to employ both the magnitude and pattern of a composite signal like the MPS signal describe the change to reflect any shift in the local environment. Finally, when compared to a baseline pattern, this change in signal magnitude and pattern reveals important information that can be employed to tailor and optimize any condition or process which involves microorganisms.